Display Channels
Channel Description Terminal Page
INIT x* ODB initialisation active - 51
FLL x* ODB filling time active - 51
STAB x* ODB stabilisation in progress - 51
COL x Temperature collector S1 51
TSTB x Temperature store 1 base S2 51
TSTT x Temperature store 1 at the top S3 51
TDIS s* Thermal disinfection temperature S3 51
S4 x Temperature sensor 4 S4 51
TFL x* Temperature flow sensor S1 / S4 /VFD 51
TR x* Temperature return sensor S4 /VFD 51
VFD x* Temperature Grundfos Direct Sensor™ VFD 51
L/h x* Flow rate Grundfos Direct Sensor™ VFD 52
n1 % x Pump speed R1 R1 52
h P1 x Operating hours R1 R1 54
h P2 x Operating hours R2 R2 54
kWh x* Heat quantity kWh - 52
MWh x* Heat quantity MWh - 52
CDIS s* Countdown of monitoring period - 53
SDIS s* Starting time display - 53
DDIS s* Heating period display - 53
TIME x Time - 53
Adjustment Channels
Channel Description Factory setting Page
Arr x System 3 54
DT O x Switch-on temperature difference R1 6.0 K [12.0 °Ra]54
DT F x Switch-off temperature difference R1 4.0 K [8.0 °Ra]54
DT S x Nominal temperature difference R1 10.0 K [20.0 °Ra]54
RIS x Rise control R1 2 K [4 °Ra] 55
PUM1 x Pump control type R1 PSOL 55
n1MX x Maximum pump speed R1 100 % 55
n1MN x Minimum pump speed R1 30 % 55
S MX x Maximum store temperature 60 °C [140 °F]56
OSEM xOption store emergency shutdown OFF 56
EM x Emergency temperature collector 130 °C [270 °F]56
Emergency temperature collector if ODB is activated: 95 °C [200 °F]56
OCC x Option collector cooling OFF 57
CMX x* Maximum collector temperature 110 °C [230 °F]57
OSYC x Option system cooling OFF 57
DTCO x* Cooling switch-on temperature difference 20.0 K [40.0 °Ra]57
DTCF x* Cooling switch-off temperature difference 15.0 K [30.0 °Ra]57
OSTC x Option store cooling OFF 57
OHOL x* Option holiday cooling OFF 57
THOL x* Holiday cooling temperature 40 °C [110 °F]59
OCN x Option minimum limitation OFF 59