Rielta OCHRANA Ladoga MK-RK User manual

WIRELESS MAGNETIC CONTACT
SECURITY DETECTORS
«Ladoga MK-RK»
«Ladoga MK-RK» version 1
1 General Information
1.1 Wireless magnetic contact security Detectors «Ladoga MK-RK»
and «Ladoga MK-RK» version 1 (hereinafter, the Detectors) are
intended for opening or shifting control of doors, windows or
other structural elements with transmission of messages to the
control panel (hereinafter, CP) via two-way wireless channel by
the «Rielta-Contaсt-R» protocol.
1.2 Opening or shifting control is fulfilled by built-in magnetic
contact monitoring. The Detectors comprise the plugs for external
inertia detectors (hereinafter, the EID) hooking up.
1.3 Two versions of Detectors are manufactured:
- «Ladoga MK-RK» – single-zone, provides a possibility for one EID
hooking up;
- «Ladoga MK-RK» version 1 – two-zone, provides a possibility for
two EID hooking up to «Loop 1» and «Loop 2».
The built-in magnetic contact and «Loop 1» are integrated in one
zone.
The built-in magnetic contact is disabled by jumper «Hermetic
Contact» (see Figure 1) applying.
1.4 Detectors operate within 433.05 – 434.79 MHz frequency range.
Their transmission power does not exceed 10 mW.
1.5 The Detectors ensure operation at the main and backup
operating frequencies. The changeover to backup operating frequency
is fulfilled automatically.
1.6 Radio communication is initiated by the Detectors at 10, 15, 30 sec
,
1, 5, 10 min intervals assigned in the process of their binding with the
CP. Alarm and tamper messages are transmitted immediately.
1.7 The Detectors are powered from main (СR123А) and backup
(СR2032) power supply batteries.
1.8 Operation modes of the Detectors are displayed by a two-color
LED indicator. The detector «Ladoga MK-RK» version 1 provides
complementary sound indication of the Detector state.
1.9 The Detectors generate and transmit the following messages:
- «Norm» – under closed built-in magnetic contacts in «Loop 1» or
resistance value in «Loop 1» less than 3.4 or more than 6.9 kΩ;
- «Intrusion to Zone 1» – under opened built-in magnetic contacts
in «Loop 1» or resistance value in «Loop 1» less than 3.4 or more than
6.9 kΩ;
- «Intrusion to Zone 2» (only for «Ladoga MK-RK» version 1) – under
resistance value in «Loop 2» less than 3.4 or more than 6.9 kΩ;
- «Tamper» – in the event of case tampering or removal from the
installation surface;
- «Main Power Supply Low Battery» – under the main power supply
battery voltage drop over 2.8-0.4 V;
- «Backup Power Supply Low Battery» – under the backup power
supply battery voltage drop over 2.8-0.4 V.
1.10 The Detectors are designed to operate continuously, around
the clock.
1.11 The Detectors have immunity to electromagnetic interference.
2 Specifications
Table 1
Parameter Value
Distance between the Detector and the magnet, mm:
- when the contact is opened
- when the contact is closed
more than 15
less than 5
Monitored loop resistance range, kΩ
- in the «Norm» state
- in the «Alarm» state
3.6 to 6.5
less than 3.4 or more
than 6.9
Operating temperatures range, °C minus 20 to +50
Permissible relative humidity at 35 °C temperature, % up to 95
Dimensions, mm, max 112 x 41 x 32
Weight, kg, max 0.1
Average service life, years 8
The operation duration under normal climate conditions and
specified broadcast period than 30 sec, not less:
- main power supply battery, months
- backup power supply battery, months
60
2
IP rating IP30
3 Scope of Delivery
The scope of delivery is listed in the Table 2.
Table 2
Name
Version
- -01
Wireless magnetic contact security Detector «Ladoga MK-RK»
Wireless magnetic contact security Detector «Ladoga MK-RK»
version1
СR123А power supply battery
СR2032 power supply battery
Magnetic contact inertia security Detector
Resistor 5.1 kΩ0.125 W
Screw 3-3х30.016
Wireless magnetic contact security Detectors «Ladoga MK-RK».
Installation Guide
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
6 pcs.
1 copy
1 pc.
1 pc.
1 pc.
2 pc.
2 pcs.
10 pcs.
1 copy
4 Design of the Detector
The Detector consists of a case and a printed circuit board (PCB).
On the front side of the PCB (1) there are located: antenna (2), built-
in hermetic contact (3), jumper for disabling of built-in magnetic
contact (5), tamper (4), two-color LED indicator (7), terminal blocks
for EID hooking up (8), main battery holder (9), «RESET» contacts
(11). There is a sound indicator situated on the face side of the
«Ladoga MK-RK» version 1. The backup power supply battery holder
and the wall tamper are located on the reverse side of the PCB. The
PCB is fixed on the base with a latch (10).
Magnet (6) of the inertial detector (supplied) is used for the built-in
hermetic contact control. The magnet should be installed opposite to
the recess in the sidewall of the base.
Figure 1
5 Indication
The following types of indication are generated by the Detectors:
a) «Binding» – procedure of logging of the Detector in the CP;
b) «Identification» indication is activated by relevant commands re-
ceived from the CP and deactivated after the Detector cover is closed
under conditions:
- other LED indication types absence;
- alarm «Tamper» message is not generated during this time;
- absence of command from the CP disabling the Detector state
indication.
Sound indication (only for «Ladoga MK-RK» version 1) is activated
by the relevant command from the CP.
The types of LED indication are listed in the Table 3.
Table 3
The Detector State Indication Note
End of the «Binding» procedure LED indicator lighting
red for 2 – 3 sec
«Binding» procedure LED indicator lighting
green
The Detector logging in
the CP
«Identification» indication LED indicator alternate
blinking red and green
By the relevant command
from the CP
«Intrusion to Zone 1»
«Intrusion to Zone 2»
Single-shot LED
indicator lighting red for
4 sec*
State indication is ON,
«Identification» indication
is OFF
Generation of:
«Intrusion to Zone 1»
«Intrusion to Zone 2»
Two-shot sound
indication unmute **
State sound indication
is ON
Restart after:
«Intrusion to Zone 1»
«Intrusion to Zone 2»
Single-shot sound
indication unmute **
Communication Quality Appraisal See sect. Communication Quality Appraisal
«Norm» Indication is OFF
* – LED indication of the Detector
** – sound indication of the Detector
Installation Guide
а) «Ladoga MK-RK» b) «Ladoga MK-RK» version 1
11
1
2
4
3
5
6
7
8
9
10
GB1 +
–RESET
Magnet
-Loop 1++Loop 2-
-Loop1++Loop 2-
11
1
2
4
3
6
7
8
9
10
GB1 +
–
Magnet
12
Rterm1 Rterm1
Rterm2
RESET
Hermetic
contact InternalExternal
5
Hermetic
contact
Internal
External
External detector External detector External detector
Rev. 10 of 29.08.16
№ 00254
v8.5
«RIELA» JSC, www.rielta.ru,
17 Chapayeva St., Saint Petersburg, Russia, 197101, [email protected],
tel./fax: +7 (812) 233-0302, 703-1360,
Technical support: tel.: +7 (812) 233-29-53, 703-13-57, [email protected]
Made in Russia
9 Storage and Transportation
9.1 The Detector in original package without power supply batteries
is resistant to:
а) transport jolting with the acceleration of 30 m/sec2with impact
frequency rate from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient temperature
+35 °С.
9.2 The Detectors in original package may be transported by any
transport facility in closed vehicles over any distances in compliance
with the existing shipping rules concerning the respective means of
transport.
9.3 After transportation under the conditions different to exploitation
conditions, the Detector shall be ready to operate after a maximum of
six hours.
10 Manufacturer’s Guarantees
10.1 «RIELTA» JSC guarantees conformity of the Detectors to the
requirements of technical conditions provided the transportation, stor-
age, installation and operation conditions are observed.
10.2 The guaranteed shelf life of the Detector is 63 months since
the date of manufacture.
10.3 The guaranteed useful life is 60 months since the day of putting
into operation.
10.4 The Detectors that are found non-conforming to the require-
ments of technical conditions shall be repaired by the manufacturer,
provided the installation and operation rules have been complied.
Note – Warranty obligations are not applied to power supply bat-
teries.
11 Acceptance and Packing Certificate
Wireless magnetic contact security Detector
«Ladoga MK-RK»,
«Ladoga MK-RK» version 1,
batch number _________________,
has been manufactured in compliance with the active technical
documentation and classified as fit for operation and packed by
«RIELTA» JSC.
Person in charge of acceptance and packing
QC representative_________________ __________________.
Date, month, year
6 Binding with the CP
The «Binding» mode is intended for the Detector logging in the CP
and service information exchange.
6.1 Prepare the CP in accordance with CP Installation Guide.
6.2 Set the backup power supply battery to the holder plate on the
PCB other side.
6.3 Set the main power supply battery to the holder (9).
6.4 Periodical LED indicator blinking green is evidence of binding
process.
6.5 In case of mentioned above LED indication absence, short-circuit
«RESET» terminals for 2 – 3 sec.
6.6 Successful binding procedure complying is indicated by LED
indicator lighting red for 2 – 3 sec.
6.7 The time limit for the binding process of the Detector is 100 sec.
To restart the binding procedure, short-circuit «RESET» terminals for
2 – 3 sec.
7 Communication Quality Appraising
7.1 For radio communication quality appraisingl it is necessary to:
- place firstly backup and then main power supply batteries to the
correspondent holder plates;
- install the PCB to the base;
- set the Detector on the assumed place of installation;
- push and then release case tamper.
7.2 After case tamper releasing the Detector generates case
tamper alarm message, transmits it via radio communication channel
and represents communication quality with CP by LED indication in
accordance with the Table 4.
Table 4
LED Indication Communication Quality
Appraisal Recommendations
Color Mode
Green Three blinks Excellent Install the Detector at this
place
Green Two blinks Good
Green One blink Communication established Choose another place
for installation or use a
repeater*)
Red Four blinks No communication
*) «Ladoga BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR» ver. 1
8 Installation of the Detectors
8.1 Before installing a Detector, remove it’s cover and withdraw the
PCB. The cover is fastened to the base by latches. To withdraw the
PCB, push up the latch (10) at the base of the Detector.
8.2 Choose the place of installation. Mark the holes layout, for the
purpose the base of the Detector can be used (See Figure 2).
Fixation holes
for the base
fastening to
the mounting
surface
Figure 2 – The Base
Antenna
holder plate
Fasten the base with screws. For the
wall tampering control fasten the screws
as shown in Figure 2. Install the PCB,
connect the wires of monitored loops to
terminal blocks (8) and close the cover.
The length of the loops must not exceed
5 m. Install the terminal (EOL) resistor
Rterm (5.1 kΩ) at the end of the loop
as shown in Figure 1. The connections
must be soldered or screwed.
8.3 When the only built-in magnetic
contact is used, EOL resistor Rterm
should be connected directly to the
«Loop 1» terminals.
8.4 In case when the built-in magnetic contact is not used, the built-
in hermetic contact jumper «Hermetic Contact» (5) should be installed.
8.5 It is not recommended to install the Detectors on metal surfaces.
The distance between the Detectors and a magnet or magnetically
conductive material should be at least 25 mm.
8.6 Irrespectively of the permissible position of the monitored
structure, the Detectors and the magnet should not be subjected to
mechanical impacts (compression, blows, etc.).

This manual suits for next models

1

Other Rielta Security Sensor manuals

Rielta FOTON-21 User manual

Rielta

Rielta FOTON-21 User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta FOTON-15A User manual

Rielta

Rielta FOTON-15A User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta STEKLO-2 User manual

Rielta

Rielta STEKLO-2 User manual

Rielta FOTON-10MD User manual

Rielta

Rielta FOTON-10MD User manual

Rielta Ladoga MK-RK version 2 User manual

Rielta

Rielta Ladoga MK-RK version 2 User manual

Rielta SH-V-10 User manual

Rielta

Rielta SH-V-10 User manual

Rielta FOTON-10M User manual

Rielta

Rielta FOTON-10M User manual

Rielta CELSIUS-RK User manual

Rielta

Rielta CELSIUS-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta C.Nord CN-Glass User manual

Rielta

Rielta C.Nord CN-Glass User manual

Rielta PYRONE-SH2-RK User manual

Rielta

Rielta PYRONE-SH2-RK User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta FOTON-SH2 User manual

Rielta

Rielta FOTON-SH2 User manual

Rielta FOTON-15B User manual

Rielta

Rielta FOTON-15B User manual

Rielta GRAN-RK User manual

Rielta

Rielta GRAN-RK User manual

Rielta Ochrana ORLAN-D User manual

Rielta

Rielta Ochrana ORLAN-D User manual

Rielta Pyrone-7 User manual

Rielta

Rielta Pyrone-7 User manual

Rielta IPDL-Ex User manual

Rielta

Rielta IPDL-Ex User manual

Rielta FOTON-10B User manual

Rielta

Rielta FOTON-10B User manual

Rielta FOTON-17 User manual

Rielta

Rielta FOTON-17 User manual

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Popular Security Sensor manuals by other brands

olympia electronics JA-80PB manual

olympia electronics

olympia electronics JA-80PB manual

Ezviz T6 quick start guide

Ezviz

Ezviz T6 quick start guide

THORLABS PDB570C Operation manual

THORLABS

THORLABS PDB570C Operation manual

Bosch DM-TP-50(80) manual

Bosch

Bosch DM-TP-50(80) manual

RKI Instruments 65-2427-05-01 Operator's manual

RKI Instruments

RKI Instruments 65-2427-05-01 Operator's manual

Assa Abloy Ditec PAS005AP user guide

Assa Abloy

Assa Abloy Ditec PAS005AP user guide

ADEMCO FlexGuard 5853 installation instructions

ADEMCO

ADEMCO FlexGuard 5853 installation instructions

RKI Instruments GD-K7D2 Operator's manual

RKI Instruments

RKI Instruments GD-K7D2 Operator's manual

Konica Minolta AeroDR System Operation manual

Konica Minolta

Konica Minolta AeroDR System Operation manual

Mustang Survival MD2010 owner's manual

Mustang Survival

Mustang Survival MD2010 owner's manual

Woodway PPS Series operating instructions

Woodway

Woodway PPS Series operating instructions

Greenlee 170XL user manual

Greenlee

Greenlee 170XL user manual

Zamel NT-320 installation instructions

Zamel

Zamel NT-320 installation instructions

United Technologies Interlogix 5500 Series installation instructions

United Technologies

United Technologies Interlogix 5500 Series installation instructions

APRVTIO ALD-100 quick start guide

APRVTIO

APRVTIO ALD-100 quick start guide

Bircher Reglomat ProxySwitch user guide

Bircher Reglomat

Bircher Reglomat ProxySwitch user guide

iRay Technology Mars1717VS user manual

iRay Technology

iRay Technology Mars1717VS user manual

Heiman HM-621THS user manual

Heiman

Heiman HM-621THS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.