WIRELESS GLASS BREAK
DETECTOR
«STEKLO-3RK»
Introduction
The detector «Steklo-3RK» (hereinafter, the Detector):
- is intended for detecting destruction of all known kinds of
construction glass: common, quenched, patterned, armored, multilayer
and laminated with polymer film, glass units, as well as hollow glass
blocks installed in structural units (openings) and/or interior elements
of closed spaces;
- transmits status messages via two-way communication in the 433.05
to 434.79 MHz frequency range to the control panel (hereinafter, CP)
supporting the «Rielta-Contact-R» wireless communication protocol;
- provides case and wall tamper protection;
- may be installed on the wall, ceiling or on a pier between the
monitored glass and curtains;
- ensures remote monitoring of controlled glazed structures of any
shape;
- provides multilevel microprocessor signal processing and functional
self-test;
- adjusts the sensitivity depending on the interference situation at
the monitored facility;
- operates at one of 4 possible operating frequencies;
- automatically switches over backup frequency in case of impairment
of interference conditions at the main operating frequency;
- is able to switch on and off an identification and status LED indication
by the CP relevant command.
Field of Application
The Detector can be applied in offices, shops, museums, exhibition
halls, banks, accommodation rooms, etc.
Specifications
Table 1
Parameter Value
Maximum detection range 6 m
Angle of coverage 120о
Installation height at least 2 m (see Figures 3 – 7)
Operating temperatures range
from minus 20 to +45
°С
Relative air humidity at 25 °С
up to 90 %
Broadcast period (programmed during
the CB binding) 10 sec to 10 min
Weight (without power batteries) maximum 0.1 kg
Dimensions
maximum 105 x 50 x 40 mm
Battery life (under normal conditions, and
messages transmitting period not less than
30 sec)
up to 3 years
IP rating IP30
Binding with the CP
The binding procedure is intended for the logging of the Detector in
the CP (repeater), assignment its number, address and the operating
frequency chosen for this CP, initialization of the data coding system
and exchange of service information.
1 Install the СR2032 backup power supply battery into the holder
located on the reverse side of the Detector PCB.
2 Install the PCB into the Detector case, thereafter install the СR123А
main power supply battery.
3 LED indicator blinking green displays the Detector readiness to the
binding procedure.
In case of the LED indication absence, the Detector should be
transferred to the «Binding» mode by closing the «RESET» contacts
until the green LED indicator starts blinking.
4 In case of successful binding with the CP (repeater), the LED in-
dicator blinks red for 1 sec.
5 The binding procedure is limited up to 100 sec, whereupon the
Detector transfers to the sleep mode. To restart the «Binding» mode
close «RESET» contacts for a short time.
Note – The zone number is determined in accordance to the CP
user manual.
Installation Guide
LED Indication
Table 2
Detector Status
Indication
«Binding» mode LED indicator blinking green periodically
«Alarm»
LED indicator single time blinking red
«Tamper» see section «Communication Quality Appraisal»
«Identification» LED indicators alternate blinking red and green
«Adjustment»
LED indicator blinking green every 1 sec under the DIP-
switch
«
3
»
is ON
«Interference»the LED indicator lights up green
Choosing the Detector Location
Before installing the Detector, get acquainted with the following
requirements:
- it is recommended to install the Detector at least 2 m height (see
examples of installation in Figures 3 – 7);
- when choosing the place of installation, the Detector detection zone
location must be taken into account (Figure 1);
- distance (L) between the Detector and the farthest point of the
monitored glass should not exceed 6 m;
- during joint operation with an active ultrasonic Detector, distance
between Detectors must be not less than 1 m;
- the entire surface of the monitored glass should be available within
the direct visibility of the Detector.
The Detector must be located within the radio visibility zone of
its repeater; therefore, it is recommended to estimate the quality of
communication with the CP (repeater).
Top View
Side View
L
L
90о
45о
120
о
Figure 1 – Detection Pattern
Communication Quality Appraising
To estimate the communication quality:
1 Place the Detector on its installation place;
2 Press the Detector tightly to a hard surface in order to close the
tamper output;
3 Remove the Detector cover. Whereupon the Detector transmits
a tamper message (the LED indicator lights red) and then the LED
indicator displays communication quality with the CP by a three-grade
scale (see Table 3).
Table 3
LED Indication Communication
Quality Appraisal
Recommendations
Color Mode
Green Three blinks Excellent
Install the Detector at
this place
Green Two blinks Good
Green One blink Communication
established
Choose another place
for installation or use a
repeater*)
Red Four blinks No communication
*) – «Ladoga BRSS-RK-RTR»
Installation of the Detector
Main fixation holes
for Detector
installation on the
mounting surface
Figure 2 – The Detector Base
Remove the cover and PCB
of the Detector and fasten
the Detector with the help of
screws. Choose the place of
the Detector installation and
mark out its fastenings using
the Detector base (
Figure
2)
for the purpose. Fix the base
by the screws (supplied).
To ensure the tamper
control, the first screw should
be screwed into the opening (1)
at the base center, the second
one must be screwed in a hole
under the wall tamper (2).
Tamper clip hole
1
2
Made in Russia
«RIELTA» JSC, www.rielta.ru
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected]
Tel./fax: +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]
Rev. 3 of 14.09.16
№
Э00164
Features and Recommendations
1 The Detector backup power supply is energized whereas the main
battery is installed.
2 The LED indication is switched off automatically in 10 minutes
after the cover is closed. To restore the LED indication lighting it is
enough to open the cover.
3 After the Detector energizing, self-testing process is activated. The
process is accompanied by the LED indicator blinking once per second.
The LED indicator blinking red for 30 sec means a possible fault.
In case of the situation repeat after the Detector is restarted, it is
recommended to substitute the Detector.
4 The «DISARM» command ensures sound processing blocking in
order to avoid false alarm in the rooms during labor hours and to save
the battery charge. The «ARM» command transfers the Detector to
a standby mode.
5 The «Identification» command allows to find the Detector assigned
to the respective monitored zone.
Storage and Transportation
1 The detectors in original package may be transported by any means
of transportation in closed vehicles over any distances in compliance
with the existing shipping rules concerning the respective means of
transportation.
2 Storage conditions of the detectors: storage premises should not
contain any current-conducting dust, acid and alkali fumes, as well
as corrosive gases or those destroying insulation.
Manufacturer’s Guarantees
The manufacturer guarantees conformity of the announcer to the
Technical Specifications requirements provided the transportation,
storage, installation and operation conditions are observed.
The guaranteed shelf life of the Detector is 63 months since the
date of manufacture.
The guaranteed useful life is 60 months since the day of putting into
operation within the guaranteed shelf life.
The Detectors that are found non-conforming to the Technical
Specifications requirements shall be repaired by the manufacturer,
provided the installation and operation rules have been complied with.
Note – Warranty obligations do not apply to the power supply
batteries.
Acceptance and Packing Certificate
The Detector «Steklo-3RK», lot number________________ has been
manufactured in compliance with the active technical documentation,
classified as fit for operation and packed by «RIELTA» JSC.
Person in charge of acceptance and packing
QC representative_________________ __________________.
day, year, month
Detector Installation Examples
Correct Detector installation options see Figures 3 – 7, the incorrect one – Figure 8
Adjustment
Set the «1», «2» and «3» DIP-switches to the OFF position. Install
the power supply batteries. Estimate the interference situation in the
room (the green LED indicator should not light up).
The green indicator lighting up means the high level of interference
in the room. Remove the interference sources if possible.
Execute adjustment of the Detector as follows:
- set the «1», «2» DIP-switches to the ON position. After it shift
DIP-switch «3» to the ON position – the «Adjustment» mode is
displayted by the green LED indicator blinking once per second;
- close the cover;
- suspend a steel ball 21 – 22 mm in diameter on a 35 cm long thread
near the farthest part of the monitored glass (ordinary, ornamental,
armed, laminated), deflect it at an angle of 30 – 70° (see Table 5, 45°
for hollow glass blocks). When the green LED indicator switches on,
deliver a test blow.
Table 4
Glass thickness, mm <3 3...4 4...5
5...6
6...7 >7
Ball deflection angle for ordinary,
armed and ornamental glass,
о
30 35 40 45 50 55
Ball deflection angle for
hardened and laminated
glass
,
о
45 50 55 60 65 70
Figure 3 – Installing the Detector
on the Ceiling
Detector
max. 6 m
Detector
Figure 5 –Installing the Detector on the
Opposite Wall
Figure 4 – Installing the Detector on
a Side Wall
min. 2 m
max. 6 m
Detector
max. 6 m
min. 2 m
Detector
min. 2 m
max. 6 m
min. 2 m
Figure 8 – Unauthorized Detector
Installation Places
Detector
max. 6 m
Figure 7 – Detector Installation
between the Glass and the Curtains
(Blinds) or on a Window Frame
Figure 6 – Installing the Detector on the Cei-
ling (for window openings in the neighboring
walls monitoring)
Detector
max. 6 m
In case the CP does not receive an alarm message after test blows,
the Detector sensitivity must be increased by DIP-switches «1» and
«2» (see Table 5).
Table 5
DIP-switch Position Detector Operating Mode
1 2 3
ON
OFF
ON
OFF
OFF
ON
ON
OFF
Sensitivity (detection
range) adjustment
Decrease by 6 dB
Decrease by 12 dB
Decrease by 18 dB (min)
Max. sensitivity
OFF
ON
Standby mode
Acoustic channel setting
- this method produces the most reliable results; however, for
adjustment the Detector for monitoring a multilayer glass or a
small area of glass, it is allowed to use an AFT-100 type electronic
glass break simulator manufactured by the «DSC»company in the
«Plat/Singl» mode or an APC type glass break simulator manufactured
by the «Argus Security»company. Besides, a simulator should be used
for adjustment the Detector to multi-glazed windows;
- check the correctness of the Detector adjustment with the Detector
cover installed;
- after completing the Detector adjustment, set DIP-switch «3» to
the OFF position.

Other Rielta Security Sensor manuals

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta Pyrone-7i User manual

Rielta

Rielta Pyrone-7i User manual

Rielta FOTON-SH2 User manual

Rielta

Rielta FOTON-SH2 User manual

Rielta FOTON-SH User manual

Rielta

Rielta FOTON-SH User manual

Rielta STEKLO-3M User manual

Rielta

Rielta STEKLO-3M User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta FOTON-10MD User manual

Rielta

Rielta FOTON-10MD User manual

Rielta FOTON-SH1 User manual

Rielta

Rielta FOTON-SH1 User manual

Rielta PYRONE-8B-RK User manual

Rielta

Rielta PYRONE-8B-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta SH-V-10 User manual

Rielta

Rielta SH-V-10 User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta FOTON-SH2-RK User manual

Rielta

Rielta FOTON-SH2-RK User manual

Rielta OCHRANA ORLAN User manual

Rielta

Rielta OCHRANA ORLAN User manual

Rielta C.Nord CN-PIR User manual

Rielta

Rielta C.Nord CN-PIR User manual

Rielta FOTON-16B User manual

Rielta

Rielta FOTON-16B User manual

Rielta SH-V User manual

Rielta

Rielta SH-V User manual

Rielta Ochrana FOTON-19RK User manual

Rielta

Rielta Ochrana FOTON-19RK User manual

Rielta FOTON-15B User manual

Rielta

Rielta FOTON-15B User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta C.Nord CN-Glass User manual

Rielta

Rielta C.Nord CN-Glass User manual

Rielta PYRONE-8B-RK User manual

Rielta

Rielta PYRONE-8B-RK User manual

Rielta FOTON-SH2-RK User manual

Rielta

Rielta FOTON-SH2-RK User manual

Rielta PYRONE-5 User manual

Rielta

Rielta PYRONE-5 User manual

Popular Security Sensor manuals by other brands

DSC PG9944 installation instructions

DSC

DSC PG9944 installation instructions

SKYLOTEC CONREST Instructions for use

SKYLOTEC

SKYLOTEC CONREST Instructions for use

Edwards Signature Series Installation sheet

Edwards

Edwards Signature Series Installation sheet

GEZE GC 173 Supplementary sheet

GEZE

GEZE GC 173 Supplementary sheet

Mitsubishi Electric KSGD-01W installation manual

Mitsubishi Electric

Mitsubishi Electric KSGD-01W installation manual

schmersal RSS 36-I2-SD-ST-DU manual

schmersal

schmersal RSS 36-I2-SD-ST-DU manual

Radenso RC-M User & installation manual

Radenso

Radenso RC-M User & installation manual

MSA Ultra Elite-H operating manual

MSA

MSA Ultra Elite-H operating manual

Velleman ham1011 manual

Velleman

Velleman ham1011 manual

Bosch DS915 installation instructions

Bosch

Bosch DS915 installation instructions

CWSI AR-5 Operating and installation instruction manual

CWSI

CWSI AR-5 Operating and installation instruction manual

Niko 351-25010 quick start guide

Niko

Niko 351-25010 quick start guide

Satel APMD-150 manual

Satel

Satel APMD-150 manual

THORLABS PDA100A2 user guide

THORLABS

THORLABS PDA100A2 user guide

Acuity Controls nLight nCM RJB Series instructions

Acuity Controls

Acuity Controls nLight nCM RJB Series instructions

SWARCO IG325/2 user manual

SWARCO

SWARCO IG325/2 user manual

DSC PG9934(P) installation instructions

DSC

DSC PG9934(P) installation instructions

AMC SR137 manual

AMC

AMC SR137 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.