Vertical mounting F models
This light generator should not be mounted with light port upwards. At high ambi-
ent temperature the operational lifetime of the internal components and harness
will be reduced.
Mounting (Accessories)
Attach to surface using 4 screws in the baseplate holes. 2 screws in the light gener-
ator. 4 screws for the driver.
Be aware that the total weight of this system is more than 5,1 kg + the downforce
from the fibre harness.
MAX AMBIENT TEMPERATURE 45°C.
Recommendations: (should always be tested in a mock up)
Secure enough space to allow natural heat transmission through surfaces.
Surfaces should not be insulated.
Cooling air for the polyconnector can not be obstructed in any way, as it is essential
to avoid damage to the harness.
General minimum distance from the light generator to any enclosing surface 10 cm
(excluded mounting surface).
Air volume per light generator minimum 0.35 m³
(For insulated surfaces the volume has to be increased)
Airflow recommendation. Should be from obstacles inlet/outlet min 30 cm.
Beware of inlet and outlet ventilation holes
opposite each other as shown on the drawing.
Keep free from dust and polluted air.
Installing adjacent light generators
Recommendation:
Minimum 30 cm distance between adjacent light generators to ensure enough free
cooling air.
If multiple rows, use offset to avoid vertical rows. Minimal free distance between
rows 40 cm.
Max temperature has to be observed for all light generators measured at air inlet
for each light generator.
MAX AMBIENT TEMPERATURE 45°C.
Closed compartments