Rohnson R-2311-20 User manual

Oil-filled radiator
MODEL: R-2311-20
Instruction Manual
This product is only suitable for well insulated spaces or occasional use.

SAFETY INSTRUCTION
1. Warning: In order to avoid overheating, do not cover the
heater.
2. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in order
to avoid a hazard.
3. This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
4. The heater must not be located immediately below a socket-outlet.
5. Do not use this heater in the immediate surroundings of a bath, a
shower or a swimming pool.
6. Children of less than 3 years should be kept away unless
continuously
supervised.
Children aged from 3 years and less than 8 years shall only switch
on/off the appliance provided that it has been placed or installed in its
intended normal operating position and they have been given
supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and clean the appliance or
perform user maintenance.
7. CAUTION —Some parts of this product can become very hot and
cause burns. Particular attention has to be given where children and
vulnerable people are present.
8. This heater is filled with a precise quantity of special oil. Repairs
re- quiring opening of oil-container are only to be made by the
manufacturer or his service agent who should be contacted if there is an
oil leak. When scrapping the heater, follow the regulations concerning
the disposal of oil.

PART FIGURE
Use of oil filled radiator
1.Turn the heater upside down.
2. As shown in figure 1, align the mounting hole of a set of caster
assembly and install it on the screw of the caster pad plate at the end
of the radiator fin, and The other caster assembly is aligned to the
screws mounted at the bottom of the control box.
3. As shown in figure 2, two sets of caster components are tightened
with four butterfly nuts. Install solid and then put the heater in place-
just put the wheels on the ground.
Fin
Control
panel
Cord wrap
Caster
assembly
butterfly
nuts
control
box

OPERATING INSTRUCTION
[Inspection before start]
1. The power cord shall not be damaged or fractured.
2. Please verify the rated current of the power socket is in line with
the requirements in the table above and is equipped with a safety
grounding device before use; otherwise, replace the socket.
[Operating Instructions]
<Work/Standby>:Plug in the power,the buzzer will “beep” for along
time,press the power key “ ” to enter the heating working state,and
then press the power key “ ” to enter the standby state.
<Gear selection>: For work status, press “ ” key to select one of
work modes such as high gear, medium gear and low gear.
<Temperature Setting>: Under the working status, press and hold the
“+ ”key or “- ”key
to set the temperature, press and hold the “+ ”key or the “-”key to
quickly set the temperature; after setting the temperature, have non-
operation for 5 seconds, exit the temperature setting screen.
<Scheduled work>: Tap the timer key " ” in standby mode to enter
the scheduled work setting screen. Press “+ ”key or “- ”key to set the
scheduled time, press “+ ”key
or “- ”key for along time to quickly set the scheduled time,and the
scheduled time will
reach the working status of the machine.
<Scheduling standby>: Under the working status, press the timer key "
" to enter the scheduling standby setting screen. Press “+ ”
key or “- ”key to set the scheduling time, press “+ ”key or “- ”key
for along time to quickly set the scheduling time and the scheduling time
is in the standby state to the machine.
A: the scope of scheduling is for 0~24hours and press "+ "key or " - "
key each time to increase or decrease 1 hour. When the set value is 0H,
press the "- "key to set the time for 24H. When the set value is 24H,
press the "+ "key and the setting time is 0H. When the set value is 0H,
the scheduling is canceled. When the set value is not 0H, the
scheduling is started. Set the appointment time, press the timing key "
" key or " "key or without operation for 5 seconds, exit

scheduling mode.
B: If the scheduling time is set, press the power button " " to
enter the standby state and cancel the scheduling.
C: After the scheduling is started, press the scheduling key " "
to check the remaining time of the appointment and reset the scheduling
time. During the scheduled time, the machine is shut down or started up
under temperature control and the scheduled time is always normal and
free from down time. During the scheduled time, it is cleared
in case of power failure.
<Memory function>: When started up the machine again and it will
operate according to the status before the last standby.
<Safety protection function>:When the indoor ambient temperature Th
exceeds 50°C under the standby or working state, all out puts are
turned off, the buzzer prompts 10 long beeps, the digital screen displays
"FF" and flash es at 1 Hz for 75 seconds. As long as there is protection,
even if the ambient temperature is less than 50°C,the running or
operation can not be resumed and the operation can only be performed
after the power is turned off and on again.
<Shut down>:Under the working state, press the power key “”
on the control panel to enter the standby state, unplug the power cord,
wait for the whole machine to cool and place the heater stably.
[Note]
To use the machine for the first time or to re-insert the socket, please
pay attention to check whether the plug and the socket are fitted well.
<Inspection method>
Insert the power plug into the socket and start for use; after about half
an hour, turn off and pull out the plug. Check whether the plug pins are
hot; replace the socket if so (more than about 50 °C) to avoid burning
the plug or even causing a fire caused by overheating of the socket due
to poor contact.

USING THE REMOTE CONTROL
Instructions for remote-control unit Button function are basically
consistent with the operation panel of the body, and the remote-control
unit cannot control the combination key.
CLEANING AND MAINTENANCE INSTRUCTION
1. The electric heater should be cleaned regularly to wipe out the dust
on the surface of flanges. As this may influence the radiating efficiency.
2. Disconnect electricity supply and allow radiator to cool, wipe out
dust with a soft damp cloth. Do not use detergent or abrasives.
3. Do not scrap the surfaces of flanges with sharp hard tools, to avoid
surfaces getting rusty, because of damage of the paint coat.
display
window
control panel

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE
WITH EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as
urban waste. It must be taken to a special local authority differentiated
waste collection centre or to a dealer providing this service. Disposing of
a household appliance separately avoids possible negative
consequences for the environment and health, deriving form
inappropriate disposal and enables the constituent materials to be
recovered to obtain significant savings in energy and resources. As a
reminder of the need to dispose of household appliances separately, the
product is marked with a crossed-out wheeled dustbin.
Information requirements for electric local space heaters
Model identifier(s): R-2311-20
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only
(select one)
Nominal heat output
Pnom
1.0
kW
manual heat charge control, with integrated thermostat
[no]
Minimum heat output
(indicative)
Pmin
0.9
kW
manual heat charge control with room and/or outdoor
temperature feedback
[no]
Maximum continuous
heat output
Pmax,c
1.0
kW
electronic heat charge control with room and/or outdoor
temperature feedback
[no]
Auxiliary electricity consumption
fan assisted heat output
[no]
At nominal heat
output
elmax
0.000
kW
Type of heat output/room temperature control (select one)
At minimum heat
output
elmin
0.000
kW
single stage heat output and no room temperature
control
[no]
In standby mode
elSB
0.000
kW
Two or more manual stages, no room temperature
control
[no]
with mechanic thermostat room temperature control
[Yes]
with electronic room temperature control
[no]
electronic room temperature control plus day timer
[no]
electronic room temperature control plus week timer
[no]
Other control options (multiple selections possible)
room temperature control, with presence detection
[no]
room temperature control, with open window
detection
[no]
with distance control option
[no]
with adaptive start control
[no]
with working time limitation
[no]
with black bulb sensor
[no]
Contact details
VASSILIAS S.A.
This product is only suitable for well insulated spaces or occasional use.
Table of contents
Other Rohnson Heater manuals

Rohnson
Rohnson R-8070 User manual

Rohnson
Rohnson R-8058 Owner's manual

Rohnson
Rohnson R-8068 User manual

Rohnson
Rohnson R-8013 User manual

Rohnson
Rohnson R-028 User manual

Rohnson
Rohnson R-017 User manual

Rohnson
Rohnson R-019 User manual

Rohnson
Rohnson R-031 User manual

Rohnson
Rohnson R-077 User manual

Rohnson
Rohnson R-2009-12 User manual
Popular Heater manuals by other brands

UNITED
UNITED UHH-812 operating instructions

Vasco
Vasco NIVA FC75 user manual

Reznor
Reznor EBHB Instructions & installation

THE RADIATOR COMPANY
THE RADIATOR COMPANY Ovali Bath Fitting instructions

Caframo
Caframo Cabinet Heater 9421CA Feature

CLIMAVENETA
CLIMAVENETA i-LIFE SLIM 102 Installation, user and maintenance manual