Sanuvox SR MAX User manual

Sanuvox Technologies Inc, © 2019 All rights reserved. October 2019 EN v.1
Instruction Manual
SR MAX
WHOLE HOME UV AIR PURIFIER & ODOR REMOVAL SYSTEM
Residential Model
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in
this manual before using the product. Failure
to comply with these instructions may result
in personal injuries or damage to the unit or
system.
1. Installation and servicing of air conditioning
and related equipment can be hazardous due
to systems pressure and electrical components.
Only trained and qualied service personnel
should install, repair or service equipment.
2. Untrained personnel can perform basic
maintenance functions such as replacing
lamp(s) and/or lter(s). All other operations
should be performed by trained service
personnel.
3. When working on the unit or system, observe
precautions in the literature, tags and labels
attached to the unit or system, and all other
safety precautions considered as best practices
in the HVAC industry.
4. When applicable, local regulation may
comprise more restrictive installation and/or
certication requirements. The afore mentioned
requirements prevail on those of this document
and the installer agrees to conform to these at
his own expense.
5. Follow all the safety instructions outlined in this
document and respect all local and national
codes applicable.
6. Never expose eyes or skin to ultraviolet light
from any source. Therefore, before installing
or performing maintenance on the unit or
system, TURN OFF AND DISCONNECT the
unit or system from all power sources (there
may be more than one switch to disconnect).
CAUTION: Electrical shock may cause
personal injuries or possibly death.
7. UV rays may destroy certain types of lters
(polymer or plastic); please keep the unit or
system light away from shining directly on
plastic.
8. When installing or performing maintenance on
the UV unit or system, it is recommended to
wear safety glasses and gloves. In order to
avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
9. UV lamps contain a small quantity of mercury:
if a lamp breaks, clean and dispose of with
care. UV lamps can be disposed/recycled after
use, as any other uorescent lamps. Contact
and follow your local and national authorities’
specic instructions.
10. Use only specied SANUVOX branded
replacement UV lamps with your unit or
system. Use of any other lamps will void your
warranty and can result in damage to the unit,
system and/or lamp(s).
11. Most UV units or systems are not waterproof.
DO NOT INSTALL OUTDOORS unless
specied otherwise.
SAVE THESE INSTRUCTIONS
Installation Date: _______________ Installed by: _________________
Installer Contact Info.: _________________________________________

2
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS 1
TABLE OF CONTENTS 2
ABOUT THE PRODUCT 3
COMPONENTS 3
How it Works 3
ACCESSORIES & KITS 3
SETUP & INSTALLATION 4
What you will need 4
What’s included 4
Step by Step Setup & Installation 4
OPERATION 7
How to Operate your Product 7
How to Read the LED Status Display 7
How to Activate “Airow Detection” Function (Optional) 8
Step by Step Function Activation 8
How to Reset your Product and its Lamp Timer 9
Step by Step Product and Lamp Timer Reset 9
MAINTENANCE 10
How to Replace Lamp(s) 10
Step by Step Lamp Replacement 10
How to Clean your Product 12
STORAGE 12
ULTRAVIOLETS: UVV & UVC 12
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 12
TROUBLESHOOTING 12
What you will need 12
Internal Components 12
Problems & Solutions Table 13
A. Step by Step SR Max Ballast Box Opening 14
B. Step by Step UV Lamp Continuity Test 14
C. Step by Step LED Display Circuit Board Bypass
(Ballast or Circuit Board Validation) 15
D. Step by Step Thermistor Deactivation 15
WARRANTY 16
CUSTOMER SERVICE 16

A
D
B
E
C
G
F
3
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
ABOUT THE PRODUCT
The SR Max represents an evolution in whole home UV air purication. The high-efciency patented design destroys airborne
bio-chemical contaminants, while providing important user information with its LED status display. Installed into the return or
supply plenum, the Sanuvox proprietary process maximizes dwell (contact) time between the air and UV energy. With the ability
to treat homes up to 2,000 sq.ft., the patented technology rapidly puries the air and removes odors within the home.
For information or recommendations on how to size your specic application, please call SANUVOX at 1-888-726-8869.
COMPONENTS
How it Works
Contaminated air enters the SR Max parallel to the UV ‘J’ Lamp, thus increasing contact time with the UV energy. The Turbulator
spins and mixes the air around the UV ‘J’ Lamp. First, the UVV oxidizing section of the lamp, boosted by Cobalt, destroys
chemicals and odors. Then, the UVC germicidal section of the lamp destroys the biological contaminants. The Aluminum
Reector Chamber coated with cobalt amplies the UV energy for optimal purication. Finally, the treated air circulates through
the home.
A. Turbulator & Air Inlet
B. Aluminum Chamber coated with cobalt
(UV Lamp inside)
C. Power Switch
D. LED Status Display
E. Cover
F. Air Outlet
G. Power Cord
ACCESSORIES & KITS
The following optional accessories and/or kits work great with your product (sold separately).
Duct Board Installation Kit
(Optional)
Accessories made to facilitate SR Max installation
on MSC duct board.
For instruction manuals or information about your optional accessories and/or kits, please call SANUVOX at 1-888-726-8869
or visit www.sanuvox.com.

4
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
SETUP & INSTALLATION
What you will need
A utility knife to unpack all components, a Phillips No.2 screwdriver or a drill, a measuring tape, a marker and a metal saw.
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,
install and setup your product. Conrm you have access to the necessary power source for the product requirements (see unit
or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The SR Max with its turbulator, a UV lamp and a basic installation kit.
The installation kit includes: a UV caution decal, a maintenance decal, a pair of cotton gloves, metal screws for frame (6), Phillips
screws for cover (4) and a frame.
Step by Step Setup & Installation
Check out Sanuvox Technologies YouTube Channel
for the SR Max installation video!
1. Prepare the SR Max for installation. Remove the contents from
packaging. Only after you have visually inspected the UV lamp should
you break the security seal on the underside of the cardboard sleeve.
CAUTION: Before installing or performing maintenance on the unit
or system, TURN OFF AND DISCONNECT the unit or system from
all power sources (there may be more than one switch to disconnect).
2. Carefully slide the UV lamp out from the cardboard sleeve. Be sure to
wear the cotton gloves (included) guaranteeing a clean lamp free from
ngerprints.
NOTE: Fingerprints on the lamp will negatively impact the UV output of
the lamp.
STEP 1
STEP 2

5
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
3. To install the UV lamp, release the reecting tube by removing the 2
screws on each side.
4. While holding the porcelain end-cap (with 4 pins), carefully push the
white connector onto the four pins. The plug is designed so that it can
only be installed one way. You may have to rotate the socket 90° to line
up the pins with the holes. The connector will t into position.
NOTE: Too much force applied from the opposite end-cap may break
the lamp.
STEP 3
STEP 4
STEP 5
STEP 6
5. Slide the UV lamp porcelain end-cap (with 4 pins) through the clamp.
Once the UV lamp is inserted, release the clamp to x the lamp in place.
6. Once the UV lamp is installed, reinstall the reecting tube. It is important
to note that the air should rst ow through the turbulator before moving
in front of the UV lamp.
STEP 7
7. Prepare the duct (return or supply) for installation. Evaluate the ideal area
for installing the air purier. The reection chamber should always be
parallel to the airow. Ensure that the purier will t into the plenum and
position it keeping in mind to minimize plastic exposure to direct UV light.
CAUTION: Before installing or performing maintenance on the unit
or system, TURN OFF AND DISCONNECT the unit or system from
all power sources (there may be more than one switch to disconnect).

6
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
STEP 11
STEP 12
STEP 9
STEP 10
STEP 8
9. Place the frame into the opening made in the duct and use the 6 metal
screws provided in the installation kit to secure it in place. Use preferably
3 top and 3 bottom holes of the frame to insert the screws.
10. Finalize the SR Max installation in the duct by placing the unit into the
frame, guided with the alignment pins.
11. Secure the SR Max to the frame with the 4 remaining screws located in
the 4 corners of the SR Max cover.
8. Use the included metal frame to trace the outline onto the duct. Allow
for a 1/8" space around the marking as to allow the frame to sit properly
in the duct. The duct opening window should have the following
dimensions: 8.5" x 5.5".
12. Use the power cord of the unit to plug into a wall outlet
that provides the power, as indicated on the marking label
of the product. An extension cord may be used if there is
not a power outlet close to where the SR Max is installed.
Then wait for one minute before turning on the unit.
You are now ready to power ON your new
SR Max and enjoy great air quality
for you and your family.
5.5"
8.5"

7
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
OPERATION
How to Operate your Product
The SR Max is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON. Wait approximately
40 seconds for the startup phase to be done and enjoy clean air in your home!
CAUTION: The suggested operating temperature range is 10 to 50°C (50 to 122°F). Operating the SR Max outside this range
will result in decreased performance. For optimal performance, air temperature moving through the reaction chamber should be
in the range of 15 to 20°C (60 to 70°F).
How to Read the LED Status Display
The SR Max’s LED Status Display will give you real time status update about your unit and its lamp.
Normal Operation
GREEN: In operation, “Default Mode”.
ORANGE (Heartbeat followed by 1 ash): Lamp over 3 years that needs to be replaced.
BLUE (Heartbeat): Stand-by, waiting for airow if “Airow Detection” is activated*.
At Start-Up
BLUE: Airow detection activated*.
WHITE: Factory setting, airow detection de-activated.
Error Code**
RED (2 ashes): Lamp or ballast failure.
RED (3 ashes): Thermistor disconnected, if thermistor is activated.
RED (4 ashes): Thermistor shorted, if thermistor is activated.
* Refer to the step by step instructions of the “Airow Detection” Function Activation on page 8.
** Refer to the troubleshooting guide on page 12.

8
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
How to Activate “Airow Detection” Function (Optional)
In “Default Mode” ( power is ON and unit operates normally), the SR Max lamp is always lit. If you activate the “Airow Detection”
function, the thermistor will detect airow and automatically turn the lamp ON or OFF as needed.
NOTE: This function is only for a certain type of HVAC furnace. When used on HVAC units with variable speed fans, this function
may cause strain on the lamp or even premature lamp failure. Your installer should know which mode is right for your unit.
Step by Step Function Activation
1. If your unit is powered ON, start by turning OFF the power switch.
2. Use a small object similar to a paper clip and insert it into the reset hole
in order to be able to press the reset button.
3. First turn ON the power switch and then, press the reset button. You
have 5 seconds from the moment the unit is powered to press the reset
button to activate the airow detection. Every time you press the button
you will notice that the LED color will either be “Blue” or “White”. Once
the LED is “Blue”, wait 5 seconds while holding the reset button for the
control circuit to save the setting.
4. From now on, the SR Max will only activate the lamp when the thermistor
detects airow in your duct system.
NOTE: The unit software is programmed to keep the lamp ON for 10
minutes after the airow has completely stopped.
STEP 1
STEP 2
STEP 3
STEP 4

9
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
How to Reset your Product and its Lamp Timer
After installing a new lamp, make sure the timer function is reset.
Step by Step Product and Lamp Timer Reset
1. To reset the lamp timer the unit needs to be powered and turned ON.
The status LED should either be “Green” or “Blue” (heartbeat).
2. Use a small object similar to a paper clip and insert it into the hole in
order to be able to press the reset button.
3. Press and hold the reset button for a minimum of 3 seconds.
When releasing the reset button, the counter will be reset to 1096 days.
STEP 1
STEP 2
STEP 3

10
Instruction Manual for SR Max
1-888-726-8869www.sanuvox.com
MAINTENANCE
How to Replace Lamp(s)
Replacing lamps on the SR Max is quick and easy. Simply turn off the power source, remove unit from duct, remove and dispose
of old lamp, replace with new Sanuvox branded UV lamp, replace unit in duct and turn power source back on. See below for
detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.
Step by Step Lamp Replacement
1. Take the SR Max out from the ductwork by removing the 4 screws
located on the cover (4 corners) that hold it to the frame.
2. Release the reecting tube by removing the 2 screws on each side to
access the lamp.
4. Prepare the new lamp. Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you break the
security seal on the underside of the cardboard sleeve.
3. Remove the old UV lamp from the lamp socket by opening the retaining
clamp and pulling the UV lamp out.
NOTE: UV lamps can be disposed/recycled after use, as any other
uorescent lamps. Contact and follow your local and national authorities’
specic instructions.
STEP 1
STEP 2
STEP 4
STEP 3
Table of contents
Other Sanuvox Air Cleaner manuals

Sanuvox
Sanuvox SANUVAIR S1000 CRO User manual

Sanuvox
Sanuvox VP900 User manual

Sanuvox
Sanuvox S1000 User manual

Sanuvox
Sanuvox GC S300-G2 User manual

Sanuvox
Sanuvox Quattro User manual

Sanuvox
Sanuvox S1000 User manual

Sanuvox
Sanuvox BIOPUR User manual

Sanuvox
Sanuvox R MAX User manual

Sanuvox
Sanuvox Quattro User manual

Sanuvox
Sanuvox P900 User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox BIOPUR User manual

Sanuvox
Sanuvox Quattro User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox S300FX User manual

Sanuvox
Sanuvox SANUVAIR S100 User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox HRV6 User manual

Sanuvox
Sanuvox FOODSAFE IL User manual

Sanuvox
Sanuvox R1r User manual