Sanuvox R1r User manual

Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1
Instruction Manual
Photos illustrating products are non contractual.
R1r
WHOLE HOME UV AIR PURIFIER
Residential Model
Installation Date: _______________ Installed by: _________________
Installer Contact Info.: _________________________________________
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
1. Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualied service personnel should install,
repair or service equipment.
2. Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or lter(s). All
other operations should be performed by trained service
personnel.
3. The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4. DO NOT hang onto the UV unit or system.
5. Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6. When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
6.1.THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE
HOT-AIR SIDE OF DUCT-TYPE SYSTEMS.
7. Units that are obviously damaged must not be operated.
8. CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9. When applicable, local regulation may comprise more
restrictive installation and/or certication requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
12.1. To reduce the risk of electric shock, this equipment has a
grounding type plug that has a third (grounding) pin. This
plug will only t into a grounding type power outlet. If the
plug does not t into the outlet, contact qualied personnel
to install the proper outlet. Do not alter the plug in any way.
12.2. The product is to be located so that connection can be
made to the source of electrical supply without the use of
an extension cord.
13. UV rays may damage certain types of lters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional uorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other uorescent lamps.
Contact and follow the specic instructions of your local
and national authorities.
15.1. Dispose of unit or system according to the specic
instructions and standards of your local and national
authorities.
16. Use only specied SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specied otherwise.
18. Use of this unit or system supplements, but does not
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact:
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
REGISTER
YOUR WARRANTY

2
Instruction Manual for R1r
1-888-726-8869www.sanuvox.com
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS 1
TABLE OF CONTENTS 2
ABOUT THE PRODUCT 3
COMPONENTS 3
How it Works 3
ACCESSORIES & KITS 3
SETUP & INSTALLATION 4
What you will need 4
What’s included 4
Step by Step Setup & Installation 4
OPERATION 6
How to Operate your Product 6
How to Read the Ballast Display 6
How to Reset your Product and its Lamp Timer 6
Step by Step Product and Lamp Timer Reset 6
MAINTENANCE 7
How to Replace Lamp(s) 7
Step by Step Lamp Replacement 7
How to Clean your Product 8
STORAGE 8
ULTRAVIOLETS 8
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 8
TROUBLESHOOTING 9
What you will need 9
Step by Step UV Lamp Continuity Test 9
Problems & Solutions Table 9
WARRANTY 10
CUSTOMER SERVICE 10

A
D
B
E
C
F
3
Instruction Manual for R1r
1-888-726-8869www.sanuvox.com
ABOUT THE PRODUCT
Installed into the return or supply plenum, the Sanuvox proprietary process maximizes dwell (contact) time between the air and
UV energy. Installed in a residential HVAC system of up to 2 tons, the patented technology rapidly puries the air within the
home.
For information or recommendations on how to size your specic application, please call SANUVOX at 1-888-726-8869.
COMPONENTS
How it Works
Foul air is exposed to the UV ‘J’ lamp of the R1r that is positionned parallel to the airow, thus maximizing exposure time to
UV light. The reective mirror surface bounces additional UV energy into the plenum. The UV lamp helps reduce the biological
contaminants. Finally, the treated air circulates through the home.
The unit automatically turns on when the duct frame’s safety pin engages the limit switch.
A. Cover
B. LED Status Display
C. Ballast Reset Button
D. Power Inlet
E. Reector (UV Lamp inside)
F. Frame
ACCESSORIES & KITS
The following optional accessories and/or kits work great with your product (sold separately).
Step-Down Transformer (AC)
ELC-TFR-12024
A transformer to convert a regular outlet (120VAC) to
24VAC.
Duct cover
SUBKIT-R1RPROT
Protective duct cover (includes spacers).
For instruction manuals or information about your optional accessories and/or kits, please call SANUVOX at 1-888-726-8869
or visit www.sanuvox.com.

4
Instruction Manual for R1r
1-888-726-8869www.sanuvox.com
SETUP & INSTALLATION
What you will need
A utility knife to unpack the components, a at screwdriver, a Phillips screwdriver, a 1/4" nutdriver, a marker and a metal saw or
sheet scissors.
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,
install and setup your product. Conrm you have access to the necessary power source for the product requirements (see unit
or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The R1r unit, reector, duct mount, a UV lamp, a 6' 24 VAC power cord and a basic installation kit.
The installation kit includes: a UV caution decal, a pair of cotton gloves, sheet metal screws (4) and 6-32 nuts (3).
Step by Step Setup & Installation
1. Prepare the R1r for installation. Unpack the duct frame and its 4 sheet
metal screws.
2. Place the duct frame on the duct at the desired location and trace the
outline to be cut (Horizontal 5.25" x Vertical 5.75").
3. Using a metal saw or sheet scissors, cut the outline.
4. Secure the duct frame to the duct using the 4 provided sheet metal
screws.
STEP 2
STEP 4
5.25"
5.75"

5
Instruction Manual for R1r
1-888-726-8869www.sanuvox.com
5. Unpack the R1r unit and reector.
6. Fasten the reector to the R1r unit using the 3 provided nuts and a 1/4"
nutdriver.
7. Remove the lamp from its packaging.
NOTE: Wear the provided cotton gloves for the following steps.
Fingerprints on the lamp will negatively impact lamp performance.
8. Carefully plug the lamp to the lamp connector. The plug is designed so
that it can only be installed one way. You may have to rotate the socket
90° to line up the pins with the holes. The connector will t into position.
9. Place the lamp on the clamp.
10. Slide the R1r unit into the duct frame ledge and swing it closed. Fasten
the safety lock at the top using a at screwdriver.
STEP 6
STEP 9
STEP 10
11. Plug the two wires of power cord to the furnace 24VAC power supply or
the step-down transformer (sold separately).
12. Plug the barrel connector of the power cord to the unit and secure
the connector by tightening its cap. The R1r will automatically begin
purifying.
You can now enjoy great indoor air quality
with your new R1r!
STEP 12
Table of contents
Other Sanuvox Air Cleaner manuals

Sanuvox
Sanuvox HRV6 User manual

Sanuvox
Sanuvox FOODSAFE IL User manual

Sanuvox
Sanuvox S1000 User manual

Sanuvox
Sanuvox SANUVAIR S100GX User manual

Sanuvox
Sanuvox Quattro User manual

Sanuvox
Sanuvox SRMax User manual

Sanuvox
Sanuvox Quattro User manual

Sanuvox
Sanuvox VP900 User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox SANUVAIR S100 User manual

Sanuvox
Sanuvox SRMax Programming manual

Sanuvox
Sanuvox P900-GX User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox P900 User manual

Sanuvox
Sanuvox S1000 User manual

Sanuvox
Sanuvox S1000 User manual

Sanuvox
Sanuvox GC S300-G2 User manual

Sanuvox
Sanuvox SANUVAIR S600 User manual

Sanuvox
Sanuvox S300 User manual

Sanuvox
Sanuvox S300FX User manual