2 AGD-100 SATEL
2. Install the battery and add the detector to the wireless system (see the ACU-100 controller
manual, installer manuals for INTEGRA 128-WRL or VERSA control panels).
3. Close the enclosure and attach the detector temporarily at the place of its future
installation. When choosing the place of installation, take into account both the range of
radio communication and the distance to protected glass.
4. Launch remotely the test mode.
5. Check the level of signal received from the detector and perform a detection test. When in
the test mode, the detector will report alarm on registering a high-frequency sound. The
INDIGO TESTER is recommended to be used for testing the detector. If necessary,
select another installation place or change the high-frequency channel sensitivity (for
information on programming sensitivity please refer to the manual for ACU-100 controller
and the programming manuals for control panels of INTEGRA and VERSA series).
6. Having selected the place which ensures the optimum signal level and glass-break
detection capability, quit the test mode.
7. Open the enclosure.
8. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting
surface.
9. Close the enclosure. The detector is now ready for work.
3. Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) ............................................................ up to 500 m
Battery.................................................................................................................... CR123A 3 V
Battery life expectancy...................................................................................... approx. 2 years
Standby current consumption .......................................................................................... 80 µA
Maximum current consumption ....................................................................................... 18 mA
Detection range...........................................................................................................up to 6 m
Environmental class according to EN50130-5 .........................................................................II
Working temperature range ...............................................................................-10 °C...+55 °C
Enclosure dimensions................................................................................... 24 x 110 x 27 mm
Hereby, SATEL sp. z o.o., declares that this detector is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC. The
declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
www.satel.pl