SATEL SLIM-PIR-PRO 3
Supervision features
In the event of the voltage drop below 9 V (±5%) for more than 2 seconds or the motion
detection system failure, the detector will signal a trouble. The trouble is indicated by the
alarm output activation and the LED indicators coming on. Signaling will continue as long as
the trouble exists.
LED indicators
The LEDs indicate:
warm-up –flashing alternately different colors for about 30 seconds;
alarm –ON for 2 seconds (default color: blue);
masking –flashing when the detector is masked (the same color of lighting as in case of
alarm);
trouble –steady ON for entire duration of the trouble (the same color of lighting as in case
of alarm).
You can change the color. You can select one of seven available colors and enable/disable
the indication of masking (see “Configuring the detector”).
You can enable / disable the LEDs. When disabled, the LEDs will not indicate the states
described above (except the indication of masking which you can enable / disable while
configuring the detector).
Enabling the LEDs by using a jumper
If you put a jumper across the LED pins, the LEDs will be enabled, i.e. they will indicate the
above described events (the LED indicators can’t be enabled/disabled remotely). If you do
not put a jumper across the pins, the LEDs will be disabled, but they can be enabled/disabled
remotely.
Remote LEDs enable/disable
The LED terminal is provided to allow remote LEDs enable/disable. When the terminal is
connected to common ground, the LEDs are enabled. When the terminal is disconnected
from common ground, the LEDs are disabled.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal an OC type control panel output programmed e.g. as “Zone test status” or “BI
switch”.
Remote configuration mode enable/disable
The SRVC terminal is provided to allow remote configuration mode enable / disable.
The configuration mode is enabled, when the terminal is connected to the common ground.
If the detector is working in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal the control panel OC type output programmed e.g. as “Service mode status” or
“BI switch”.
3. Electronics module
Do not remove the plastic cover from the circuit board to prevent damage to the
components located on the board.
Do not touch the pyroelectric sensor, so as not to soil it.