Chassis Installation
CAUTION!
Ventilation for the SVR-5000S is provided by air entering
through the gap around the bottom cover and then exiting
through the vent at the rear of the host. Ensure that when the
SVR-5000S is placed there are no obstructions to the airflow
around the bottom cover or rear of the host.
Rack Installation
The SVR-5000S can be rack mounted using the RCK-3000-xx
(purchased separately) which provides easy access to the
SVR-5000S via a removable faceplate and sliding shelf. The open
shelf design provides proper ventilation and easy access to wiring.
Network Requirements
Savant requires the use of business class/commercial grade network
equipment throughout the network to ensure the reliability of
communication between devices. These higher quality components
also allow for more accurate troubleshooting when needed.
Connect all Savant devices to the same local area network (LAN) or
subnet as the host. Savant recommends not implementing any type
of traffic or packet shaping in your network topology for the Savant
devices as this may interfere with performance.
Network Configuration
To ensure that the IP Address will not change due to a power
outage, a static IP Address or DHCP reservation should be
configured. Savant recommends using DHCP reservation within the
router. By using this method, static IP Addresses for all devices can
be managed from a single UI avoiding the need to access devices
individually.
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.
Network Changes
After connecting to a new network, changing routers, or if the IP
Address range is changed in the current router, Savant recommends
the following steps. This will reset any IP connection and ensure
that the host is communicating with the network correctly.
•Hot Plug the Ethernet (LAN) Connection
1. Disconnect the Ethernet (LAN) connection from the host.
2. Wait 15 seconds and then reconnect.
Precautions
SURGE PROTECTION!
Use a surge-protected circuit for all components and power
supplies requiring 120-240V AC 50/60 Hz source power.
ELECTRICAL DISCONNECT!
The 120-240V AC 50/60 Hz source power outlet and input
power sockets should be easily accessible in the event of an
electrical hazard or malfunction condition.
Power Management Recommendations
Savant recommends a pure sine wave uninterruptible power supply
(UPS) with the ability to shut down the SVR-5000S before the
battery runs out of power. Never remove power from the
SVR-5000S before shutting it down.
Additional Documentation
For additional information, refer to the following documents on
Savant.com.
•Savant Pro Host - Deployment Guide - 009-0263-xx
SVR-5000S-00 | 009-1300-00 | 141229
SVR-5000S-00 | 009-1300-00 | 141229