manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Savant
  6. •
  7. Transmitter
  8. •
  9. Savant PAV-VIM4S series User manual

Savant PAV-VIM4S series User manual

PAV-VIM8S-00/PAV-VIM4S-00 | 009-1480-01 | 171201
Copyright 2017 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
1 of 2
Box Contents
(1) Audio/Video over IP Switch (PAV-VIM8S-00/PAV-VIM4S-00)
(1) Installation Kit (075-0192-xx/075-0197-xx)
(2) Standard 3U Rack Mounting Brackets (071-0638-xx)
(4) M5 x 8 mm Flat-head Phillips Screws (039-0180-xx)
(1) 6 ft Power Cord (064-0079-xx N. America)
or 6ft Power Cord (International can vary)
(16 or 8) 3-pin Control Connectors (028-9351-xx)
(1) Quick Reference Guide (this document)
Required Components
Savant Audio/Video over IP Device (PAV-VOMVP1F/PAV-VOMVP1C)
Savant System Host
Savant qualified 10G Managed Network Switch
Savant User Interface
Savant Design and Configuration Tools
Compliance
Safety and
Emissions
FCC Part 15 CE C-Tick ETL
RoHS Compliant
1 = at 24 Hz
2 = at 25 Hz
3 = at 30 Hz
4 = at 50 Hz 5 = at 60 Hz
Audio
Supported
Formats
Pass-though of all HDMI audio formats are
supported.
Video
HDR Supported
Supported
Formats
640x4805
720x4805
720x5764
800x6005
1024x7685
1280x7204
1280x7205
1280x10245
1920x10801
1920x1080
1920x10804
1920x10805
1920x12005
3840x21601
3840x21602
3840x21603
3840x21604
3840x21605
Power
Input Power 100-240V AC 50/60Hz, (5A maximum)
Nominal Power N. America - 144VA - (1.2 A @ 120V AC, 60Hz)
International - 156VA - (.68 A @ 240V AC 50Hz)
Maximum Power N. America - 400VA - (4 A @ 120V AC, 60Hz)
International - 432VA - (1.8 A @ 240V AC 50Hz)
Power Cable IEC320 C13 three-pole detachable power card
Dimensions and Weights
Height 5.21 in (132.3 mm)
Width 17.30 in (439.4 mm)
Depth 14.24 in (361.7 mm)
Weight Net: 14.5lb (6.59 kg) | Shipping 18.25lb (8.27 kg)
Rack Space 3U
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 10% to 90% Relative Humidity (non-condensing)
Cooling 70 cubic feet per minute (CFM) recommended
BTU 1365 BTU/hr
Specifications
Item Description
On / O
Button
Reboots the main board (mcu) and power cycles
the IP Video transmit (Tx) cards
Reset Button
Press and Release - Resets the IP Video transmit
(Tx) cards.
Press and hold – Clears the network settings.
Press and hold button for 5 seconds until Status
LED blinks red rapidly; then release.
Power LED O – Device is o. No power applied.
Green – Main board is powered
Status 1 LED
Blinks Twice – Provisioned to the local network
and is currently connecting to the Host
Rapid Blink (green) – The reset button was
pressed and held for five seconds and the A/V
over IP unit is performing a factory reset. All
network settings are cleared.
Short O Blink – Firmware is updating
Status 2 LED Reserved for future use.
A
B
C
D
E
ABC D E
Front Panel
Network Configuration
To ensure that the IP Address will not change due to a power outage,
Savant recommends using DHCP reservation within the router. By
using this method IP Addresses for all devices can be managed from a
single UI, avoiding the need to access devices individually.
NOTE: Setting DHCP reservation varies from router to router. Refer to
the documentation for the router to configure DHCP reservation.
Network Requirements
The A/V over IP device requires a Savant qualified 10G managed
switch. This switch must be configured for the A/V over IP devices. For
more information on this see the Savant Audio/Video over IP Network
Configuration Guide on the Savant Customer Community.
Installation
The Savant Audio/Video over IP 8-Port / 4-port Transmitter chassis
can be mounted using the included rack mounting ears and hardware
in a 3U rack style enclosure and is compatible with all standard 19-inch
National Electrical Manufacturers Association (NEMA) rack mounts.
For more information see the Savant Audio/Video over IP Deployment
Guide on the Savant Customer Community.
For Product Info
Savant® ProAV Video 8 or 4 Input IP Transmitter 4K UHD
with Control (PAV-VIM8S/PAV-VIM4S)
Quick Reference Guide
PAV-VIM8S-00/PAV-VIM4S-00 | 009-1480-01 | 171201
Copyright 2017 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
Item Description
1 Gigabit
Ethernet
1G of reserved network data bandwidth
commonly used to connect any network
compliant device to transmit its data onto the
Ethernet network by sharing the 10G network
link. 8-Pin RJ-45 female connection.
IMPORTANT!: Do not connect these ports to a
network switch.
10 Gigabit
Ethernet
SFP+ Housing; Used for connectivity to the 10G
Ethernet Network Switch
IMPORTANT!: For all 10G connections, use only
Savant certified SFP+ Direct-Attach Copper
(DAC) cables, or Savant certified fiber and fiber
connectors along with Savant certified SFP+
modules.
Rx/Tx LEDs
(10 GbE)
Rx – Link Activity LED indicator for all data
received on the 10G connection
Tx – Link Activity LED indicator for all data
transmitted from the 10G connection
HDMI In
19-Pin Type A HDMI female digital audio/video
input.
Supports HDMI 2.0a
HDMI 2.0 compliant cable is required for 4K
content.
Power Input
Module
100-240V AC 5A 50/60Hz power input module
with On/O switch.
I – Applies power to the device.
O – Removes power to the device.
NOTE: Includes a field replaceable 5A 250V Fast
acting fuse.
RS-232
Control Port
RS232 – 3-pin Screw down plug-in connection.
Transmits and receives serial data to and from
serial controllable devices. For pin-out informa-
tion, refer to the RS-232 Wiring section below.
IR Control
Port
IR - 3-pin Screw down plug-in connection.
Transmits IR signals via an IR Flasher
(5V tolerant) to devices with an IR input or IR
receiver. For pin-out information, refer to the IR
Wiring section below.
Analog
Audio Out
RCA Analog Audio Output.
Requires HDMI input stereo PCM audio format.
Direct Line Level 2.1-VRMS Output
Push Buttons Push buttons – Reserved for future use.
Ethernet 8-Pin RJ-45 female connection. Used to
communicate with the Savant System Host.
Reserved 8-Pin RJ-45 female connection;
Reserved for future use
Grounding Chassis Ground (optional)
A
B
C
D
E
F
G
H
I
J
K
L
LRLR R LRL L
R R L L
R R
LKJ
I
HGF
ED
C
B
A
Rear Panel Wiring and Connections
IR connections are made using a 3-pin
Control Connector supplied with the device.
The wire slips into the hole and locks with a
screw located at the top of the connector.
IMPORTANT: IR Wiring Precautions
Ensure that all IR emitters are within 15 feet
(4.6 meters) from the controller’s location.
Use of 3rd party blinking IR emitters with
Talk Back is not recommended. These types of emitters can draw
voltage away from the IR signal that can degrade IR performance.
3
2
1
PIN 1
IR -
PIN R +
PIN 3
Not Used
Out
G
IR Wiring
2 I
Serial control connections are made using
a 3-pin Control Connector supplied with
the device. The wire slips into the hole and
locks with a screw located at the top of the
connector.
RS-232 Wiring
3
2
1
PIN 1
Ground
PIN ransmit
PIN 3
Receive
Rx
Tx
G
2 T
Enhanced small form-factor pluggable connection. Use
a Savant certified Direct Access Copper (DAC) SFP+
cable to connect the chassis to the 10G switch, or Savant
certified fiber and fiber connectors along with Savant
certified SFP+ modules.
Transport Distance
DAC cable 10 ft (3 m)
OM3 multi-mode Fiber 1000ft (300 m)
SFP+ 10 GbE
Replace the Fuse
A
B
Connection Pins Towards Unit
Open Side of Cartridge Towards Power Switch
A
B
ELECTRIC SHOCK HAZARD: Disconnect the unit from AC power
by removing the power cord from the AC outlet and the unit before
replacing the fuse.
IMPORTANT: The orientation of the cartridge within the unit and lo-
cation of the fuse within the cartridge are crucial to proper operation.
Make note of the orientation of the cartridge and the fuse location
within the cartridge before removing.
1. Disconnect the unit from AC power by removing the power cord.
2. Open the fuse cover on the AC power input using a flat head
screwdriver or similar thin flat head tool. This will allow access to the
fuse cartridge.
3. Using a flat head screwdriver or similar thin flat head tool, gently
loosen the cartridge and pull the cartridge out of the unit slowly. As
the cartridge is removed, make note of the orientation, as it is import-
ant to proper operation.
TIP: Mark the chassis and fuse holder with a marker in order to align
when replacing.
4. Remove the old fuse from the cartridge and discard.
5. Gently place the new fuse in
the cartridge and place the
cartridge part way into the
receptacle aligning it as
defined in the diagram.
6. Gently press on the cartridge the rest of the way until it seats into
the terminals at the rear of the slot.
NOTE: If any resistance is encountered during seating the cartridge,
DO NOT apply more pressure. Stop pressing on the cartridge, remove
it, verify the orientation, and repeat step.
Additional Information
Refer to the following documents located on the Savant Customer
Community for additional information.
– Savant Audio/Video over IP Deployment Guide (009-1551-xx)
– Savant Audio/Video over IP Network Configuration Guide
(009-1552-xx)

This manual suits for next models

1

Other Savant Transmitter manuals

Savant PAV-VIMAP8S User manual

Savant

Savant PAV-VIMAP8S User manual

Savant PAV-VIM8S series User manual

Savant

Savant PAV-VIM8S series User manual

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant PAV-VIMAP8S User manual

Savant

Savant PAV-VIMAP8S User manual

Savant ProAV PAV-VIM8S User manual

Savant

Savant ProAV PAV-VIM8S User manual

Savant PAV-AIM7C User manual

Savant

Savant PAV-AIM7C User manual

Savant PAV-AIM7C-10 User manual

Savant

Savant PAV-AIM7C-10 User manual

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant PAV-VIM8S series Quick reference guide

Savant

Savant PAV-VIM8S series Quick reference guide

Savant PAV-VIMVP1F User manual

Savant

Savant PAV-VIMVP1F User manual

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant

Savant SmartLink HDBaseT HTX-SLN501 User manual

Savant PAV-VIM8S series User manual

Savant

Savant PAV-VIM8S series User manual

Popular Transmitter manuals by other brands

Camille Bauer KINAX WT 717 operating instructions

Camille Bauer

Camille Bauer KINAX WT 717 operating instructions

Stahl ISpac 9182 Series manual

Stahl

Stahl ISpac 9182 Series manual

Honeywell 5820L - Slim Line Wireless Door/Window... Installation and setup guide

Honeywell

Honeywell 5820L - Slim Line Wireless Door/Window... Installation and setup guide

BEKA BA474ND Installation & maintenance instructions

BEKA

BEKA BA474ND Installation & maintenance instructions

BAPI H200 Installation and operating instructions

BAPI

BAPI H200 Installation and operating instructions

Viatran 517 Installation data manual

Viatran

Viatran 517 Installation data manual

GAPOSA Emitto Smart 16 QCTZ16Y Installer manual

GAPOSA

GAPOSA Emitto Smart 16 QCTZ16Y Installer manual

Kobold NGM-HART operating instructions

Kobold

Kobold NGM-HART operating instructions

Endress+Hauser tmt142 Brief operating instructions

Endress+Hauser

Endress+Hauser tmt142 Brief operating instructions

ABB 266CRH instructions

ABB

ABB 266CRH instructions

aci B5 Installation, operation and maintenance manual

aci

aci B5 Installation, operation and maintenance manual

ARG ARG-OM-027 Manual and user guide

ARG

ARG ARG-OM-027 Manual and user guide

DLO TuneStik DLZ62000 user manual

DLO

DLO TuneStik DLZ62000 user manual

King Pigeon IOT100 user manual

King Pigeon

King Pigeon IOT100 user manual

Vega VEGABAR 83 operating instructions

Vega

Vega VEGABAR 83 operating instructions

Transmitter Solutions Firefly3 FIRlll310LID22K3 manual

Transmitter Solutions

Transmitter Solutions Firefly3 FIRlll310LID22K3 manual

OTT Hydrolab DS5X user manual

OTT

OTT Hydrolab DS5X user manual

Savio TR-12 user manual

Savio

Savio TR-12 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.