SECO-LARM SD-9163-KSQ User manual

Outdoor Wave-to-Open Sensors
Manual
Language Slimline Plate Single-Gang Plate European Plate
English
SD
-
9163
-
KSQ
*
SD
-
9263
-
KSQ
*
SD
-
9363
-
KSQ
*
Spanish
SD
-
9163
-
KS1Q
*
SD
-
9263
-
KS1Q
*
SD
-
93
63
-
KS1Q
*
French
SD
-
9163
-
KS2Q
*
SD
-
9263
-
KS2Q
*
SD
-
93
63
-
KS2Q
*
English
w/ mechanical o erride button
SD
-
9163
-
KSVQ
SD
-
9263
-
KSVQ
S
D
-
93
63
-
KSVQ
†
The ENFORCER Outdoor Wa e-to-Open Sensor is a full-featured exit plate which uses IR
technology to allow egress from a protected area or acti ate a de ice with the simple wa e of a
hand. Since no touch is required, this sensor is suitable for use in hospitals, clinics, labs,
cleanrooms (to reduce the risk of contamination), schools, factories, or offices.
*Weatherproof when installed properly (see page 3 for details)
†
Spanish and French also a ailable
Featuring
:
•Built-in Timer (0.8~30 seconds or toggle)
•Programmable LED (Red to Green or Green to Red)
™
ENFORCER
®
Wave-to-Open Sensor
2 SECO-LARM
U.S.A., Inc
Features:
•
Adjustable sensor range up to 7" (18cm)
•Weather resistant for outdoor use (except
models with mechanical o erride button)
•Stainless steel plate
•1.2A relay, adjustable trigger duration
0.8~30 seconds or toggle
•
LED illuminated sensor area for easy
identification
•Selectable LED colors (turns from red to
green or green to red) to show sensor
acti ated
Overview:
Specifications:
Power 12~24 VDC
Current
drain
(max.)
Standby 16mA@12VDC / 25mA@24VDC
Triggered 25mA@12VDC / 32mA@24VDC
Relay type SPDT dry contact, 1.2A@24VDC
Response time 10ms
LEDs Standby Red
†
Triggered Green
†
Output time 0.8~30 s, toggle
Range 2”~7” (5~18 cm)
IP rating IP65
‡
Temperature range -4°~131° F (-20°~55° C)
Weight
Single Gang 108g
Single Gang
w/ Mechanical O erride
125g
Slimline 61g
Slimline
w/ Mechanical O erride
77g
European Plate 77g
†
Color function re ersible
‡
When properly installed (not including models with o erride button)
1
1
/
2
"
(39mm)
2
3
/
4
"
(70mm)
Sensor range adjustment
Trigger time adjustment
LED control jumper
5-pin connector
SPDT Mechanical o erride*
4
1
/
2
"
(115mm)
*
SD
-
9163
-
KSVQ and SD
-
9263
-
KSVQ
only
SD-9263-KSVQ shown
4
1
/
2
"
(115mm)
86mm
86mm
European Plate
2
3
/
4
"
(70mm)
ENFORCER
®
Wave-to-Open Sensor
SECO-LARM
U.S.A., Inc 3
Wiring Diagram:
Installation:
1. Run four wires through the wall to a single-gang, slimline, or European back box.
2. Connect the four wires from the back box to the Request-to-Exit Sensor according the Wiring
Diagram abo e.
3. For weatherproof installation, use a waterproof back box and apply a bead of silicone sealant (not
included) around the rim of the back box and faceplate edge. Apply a small amount of sealant
below each screw head.
4. Screw the plate into the back box, taking care not to crimp the wires and ensuring a good seal.
5. Remo e clear protecti e film from the sensor before use.
W RNING: Do not connect any de ice that will exceed 1.2A@24VDC.
Changing the LED Color Jumper Placement:
Slimline Models Single-Gang Models
djusting the sensor range and trigger time:
1. The sensor range can be adjusted from 2”~7” (5~18 cm).
2. The trigger time can be adjusted from 0.8 to 30 seconds or toggle*.
NOTE: Do not force the adjustment trimpots to turn. Only minimal force
is needed.
Standby: Green
Trigger: Red
Standby: Red
Trigger: Green
(default)
Place here for:
Standby: Green
Trigger: Red
Place here for:
Standby: Red
Trigger: Green
(default)
Red Wire: +12~24 VDC
Brown Wire: Ground (
-
)
Blue Wire: COM
Purple Wire: N.O.
Green Wire: N.C.
Red Wire: +12~24 VDC
Brown Wire: Ground (
-
)
Blue Wire: COM
Purple Wire: N.O.
Green Wire: N.C.
Slimline models
Single-gang models
Wiring for
Wa e
-
to
-
Open
Sensor
(SD-9263-KSQ shown)
Wiring for
Wa e
-
to
-
Open
Sensor
with Form C Mechanical O erride Button
(SD-9263-KSVQ shown)
Sensor range
adjustment
Trigger time
adjustment
*Set trigger time to maximum for toggle
Trigger time: 0.
8
~
3
0 seconds, toggle
*
Default: 0.8 seconds
*Toggle: turn all the way clockwise
Sensor range:
2”~7” (5~18 cm)
Default: 7” (18cm)
Red Wire: +12~24VDC
Brown Wire: Ground (-)
Blue Wire: COM
Purple Wire: N.O.
Green Wire: N.C.
Red Wire: +12~24VDC
Brown Wire: Ground (-)
Blue Wire: COM
Purple Wire: N.O.
Green Wire: N.C.
ENFORCER
®
Wave-to-Open Sensor
4 SECO-LARM
U.S.A., Inc
Sample Installation:
Typical installation with an electric lock:
Care and Cleaning for the SD-9x63 Series Sensor:
The sensor requires special care to ensure reliability and a long operating life.
1. Use a soft, clean cloth for cleaning. Use the mildest type of cleaner a ailable.
2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
3. Be sure to wipe off any excess liquid from the sensor. Wet spots may affect the sensor’s
performance.
O erride button is prewired in the factory
No further wiring necessary
NOTICE
:
The SECO
-
LARM policy is one of continual de elopment and impro ement. For that reason, SECO
-
LARM
reser es the right to change specifications without notice. SECO-LARM is also not responsible for misprints.
All
trademarks are the property of SECO-LARM U.S.A., Inc. or their respecti e owners. Copyright © 2020
SECO-LARM U.S.A., Inc. All rights reser ed.
W RR NTY:
This SECO
-
LARM product is warranted against defects in material and workmanship while
used in normal
ser ice for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repai
r or
replacement of any defecti e part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is oid if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole
obligation of SECO-LARM and the purchas
er’s exclusi e remedy, shall be limited to the replacement or repair only, at
SECO-LARM’s option. In no e ent shall SECO-
LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
IMPORT NT:
Users and installers of this product are responsible for ensuring that the installation and configuration of
this product complies with all national, state, and local laws and codes related to locking and egress de ices.
SECO-LARM will not be held responsible for the use of this product in iolation of any current laws or codes.
IMPORT NT W RNING:
For a weatherproof installation, ensure the unit is installed in a waterproof back
box, and that
the faceplate and faceplate screws are properly sealed. I
ncorrect mounting may lead to exposure to rain or moisture in
the enclosure which could cause a dangerous electric shock, damage the de ice, and oid the warranty. Users and
installers of this product are responsible for ensuring this product is properly installed and sealed.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan A enue, Ir ine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800
Email: sales@seco
-
larm.com
PITSW1
Order Part#
763
-
171
-
8
%
MI_SD
-
9x63
-
KSxQ_200713.docx

Other manuals for SD-9163-KSQ

2

This manual suits for next models

20

Other SECO-LARM Accessories manuals

SECO-LARM SD-927PWCQ User manual

SECO-LARM

SECO-LARM SD-927PWCQ User manual

SECO-LARM RA-4961-MBQ User manual

SECO-LARM

SECO-LARM RA-4961-MBQ User manual

SECO-LARM ENFORCER CS-PD535-TAQ User manual

SECO-LARM

SECO-LARM ENFORCER CS-PD535-TAQ User manual

SECO-LARM Enforcer SM-205Q/W User manual

SECO-LARM

SECO-LARM Enforcer SM-205Q/W User manual

SECO-LARM ENFORCER E-961-S90WQ User manual

SECO-LARM

SECO-LARM ENFORCER E-961-S90WQ User manual

SECO-LARM Enforcer SD-927PKC-NEQ User manual

SECO-LARM

SECO-LARM Enforcer SD-927PKC-NEQ User manual

SECO-LARM ENFORCER E-9626-2B190Q User manual

SECO-LARM

SECO-LARM ENFORCER E-9626-2B190Q User manual

SECO-LARM ENFORCER E-931-S33PRGQ User manual

SECO-LARM

SECO-LARM ENFORCER E-931-S33PRGQ User manual

SECO-LARM SD-9163-KSQ User manual

SECO-LARM

SECO-LARM SD-9163-KSQ User manual

SECO-LARM SLI ENFORCER E-936-S45RRGQ User manual

SECO-LARM

SECO-LARM SLI ENFORCER E-936-S45RRGQ User manual

SECO-LARM E-931-S33PRQ User manual

SECO-LARM

SECO-LARM E-931-S33PRQ User manual

SECO-LARM Enforcer SD-7251GCEX1Q User manual

SECO-LARM

SECO-LARM Enforcer SD-7251GCEX1Q User manual

SECO-LARM ENFORCER E-931-S45RRQ User manual

SECO-LARM

SECO-LARM ENFORCER E-931-S45RRQ User manual

SECO-LARM Push-to-Exit Bar SD-961A-36 User manual

SECO-LARM

SECO-LARM Push-to-Exit Bar SD-961A-36 User manual

SECO-LARM SD-9163-KSQ User manual

SECO-LARM

SECO-LARM SD-9163-KSQ User manual

SECO-LARM ENFORCER CS-PD115-PAQ Installation guide

SECO-LARM

SECO-LARM ENFORCER CS-PD115-PAQ Installation guide

SECO-LARM Push-To-Exit Bar SD-969-A18 User manual

SECO-LARM

SECO-LARM Push-To-Exit Bar SD-969-A18 User manual

SECO-LARM ENFORCER SM-200Q/W User manual

SECO-LARM

SECO-LARM ENFORCER SM-200Q/W User manual

SECO-LARM ENFORCER SD-R400-BQ User manual

SECO-LARM

SECO-LARM ENFORCER SD-R400-BQ User manual

SECO-LARM ENFORCER SM-205Q/W User manual

SECO-LARM

SECO-LARM ENFORCER SM-205Q/W User manual

SECO-LARM SLI ENFORCER E-931-S50RRGQ User manual

SECO-LARM

SECO-LARM SLI ENFORCER E-931-S50RRGQ User manual

Popular Accessories manuals by other brands

MCOHome MCOEMH9-CO2-230 manual

MCOHome

MCOHome MCOEMH9-CO2-230 manual

Onelink OLCONTACTA quick start guide

Onelink

Onelink OLCONTACTA quick start guide

Pure Fun 9307TS product manual

Pure Fun

Pure Fun 9307TS product manual

In-situ Partech ChemScan RDO-X Stainless Steel instructions

In-situ

In-situ Partech ChemScan RDO-X Stainless Steel instructions

Air TEc CYPRES instruction manual

Air TEc

Air TEc CYPRES instruction manual

REV MAX! operating manual

REV

REV MAX! operating manual

Co2meter CM-7000 user manual

Co2meter

Co2meter CM-7000 user manual

Fly Sky FS-iBA01 manual

Fly Sky

Fly Sky FS-iBA01 manual

Tripp Lite B114-002-R owner's manual

Tripp Lite

Tripp Lite B114-002-R owner's manual

Delta-T Devices WET150 quick start guide

Delta-T Devices

Delta-T Devices WET150 quick start guide

woodmizer PD200 Series Safety, Operation, Maintenance & Parts Manual

woodmizer

woodmizer PD200 Series Safety, Operation, Maintenance & Parts Manual

wattstopper FS-705 installation instructions

wattstopper

wattstopper FS-705 installation instructions

TScale BW Series Technical manual

TScale

TScale BW Series Technical manual

Alarmcom Flex IO installation guide

Alarmcom

Alarmcom Flex IO installation guide

SpyCameraCCTV SPYPEN720 Product guide

SpyCameraCCTV

SpyCameraCCTV SPYPEN720 Product guide

SUP’AIR Strike user manual

SUP’AIR

SUP’AIR Strike user manual

REV G01102.2 Series manual

REV

REV G01102.2 Series manual

MasterChef EH-380-16 instruction manual

MasterChef

MasterChef EH-380-16 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.