Digital output module F-DQ 8x24VDC/2A PPM (6ES7526-2BF00-0AB0)
Manual, 01/2016, A5E03858037-AA 7
Preface ................................................................................................................................................... 4
1 Documentation guide .............................................................................................................................. 9
1.1 Guide to documentation S7-1500 / ET 200MP.........................................................................9
2 Product overview .................................................................................................................................. 12
2.1 Properties................................................................................................................................12
3 Connecting ........................................................................................................................................... 15
3.1 Block diagram .........................................................................................................................15
4 Parameters/address space ................................................................................................................... 18
4.1 Parameters .............................................................................................................................18
4.2 Explanation of parameters ......................................................................................................20
4.2.1 F-parameters ..........................................................................................................................20
4.2.1.1 Behavior after channel fault ....................................................................................................20
4.2.1.2 Reintegration after channel fault.............................................................................................20
4.2.2 DQ parameters .......................................................................................................................21
4.2.2.1 Maximum test period...............................................................................................................21
4.2.2.2 Operating mode of the output .................................................................................................21
4.2.3 Parameters of the channels....................................................................................................21
4.2.3.1 Diagnostics: Wire break ..........................................................................................................21
4.2.3.2 Channel activated ...................................................................................................................21
4.2.3.3 Channel failure acknowledge..................................................................................................22
4.2.3.4 Max. readback time dark test..................................................................................................22
4.2.3.5 Disable dark test for 48 hours.................................................................................................25
4.2.3.6 Max. readback time switch-on test .........................................................................................26
4.2.3.7 Activated light test...................................................................................................................28
4.3 Address space ........................................................................................................................30
5 Applications of the F-I/O module ........................................................................................................... 32
5.1 Applications for the F-DQ 8x24VDC/2A PPM.........................................................................32
5.2 Application: Connecting a load per digital output, PM switching ............................................33
5.3 Application: Connection of loads per digital output to L+ and M, PM-switching mode...........34
5.4 Application: Connecting 2 loads in parallel per digital output, PM-switching mode ...............37
5.5 Application: Connecting a load per digital output, PP switching.............................................39
6 Interrupts/diagnostic messages............................................................................................................. 41
6.1 Status and error displays ........................................................................................................41
6.2 Interrupts.................................................................................................................................44
6.3 Diagnostic alarms ...................................................................................................................46