P/N 315-096018-8
Installation Instructions
Model SZE-4X
Zone/Output Expander Module
Mounting the SZE-4X (Refer to Figure 1):
Install the Main Board of the SXL-EX or SXL-EX-INT
(See the SXL-EX Operation, Installation, and Mainte-
nance Manual, P/N 315-095997). Then install the
SZE-4X in the lower portion of the EN-SX enclosure
by following the steps listed below.
1. Screw the four standoffs onto the four studs
located in the lower portion of the SXL-EX
enclosure.
2. Place the SZE-4X over the four standoffs. Using
the four screws provided, fasten the SZE-4X
board to the standoffs.
Wiring
See Figure 2 for wiring connections from the SZE-4X
to the SXL-EX Main Board.
PROGRAMMING
Refer to the SXL-EX Operation, Installation, and
Maintenace Manual (P/N 315-095997) for program-
ming instructions related to IDC Zones, and Open
Collector and Relay Outputs.
OPERATION
The Model SZE-4X Zone/Output Expander module
from Siemens Industry, Inc., is used with the SXL-EX
to provide an additional four Class B (Style B) Initiating
Device Circuits, four Form C Relays, and four Open
Collector Output Circuits. All the devices on these
circuits are user programmable. Each inititiating
device circuit can drive up to 30 conventional type
detectors and an unlimited number of shorting type
devices. The SZE-4X can also be used with the
SXL-EX-INT.
ELECTRICAL CHARACTERISTICS
Supervisory: 41mA at 24 VDC
Alarm: 510mA at 24 VDC
Each IDC 120mA at 24 VDC
Each Relay 26mA at 24 VDC
INITIATING DEVICES
Each SZE-4X IDC Zone can connect to the initiating
devices indicated below:
1. Up to 30 smoke detectors may be used on an
SZE-4X zone. Compatible detectors are listed in
Table 1. Detectors of different models are not to
be mixed or matched on a system.
2. The PBA-1191 Beam Detector may be used as
shown in Figure 4. Only one PBA-1191 Beam
Detector may be used on an SZE-4X zone and
eight total on the system.
3. Any number of shorting type devices can be used
on a SZE-4X zone.
Refer to Figures 2, 3, and 4 for the wiring of the
detectors, shorting type devices, and the beam
detector devices.
INSTALLATION
Remove all system power before
installation, first battery and then AC.
(To power up, connect the AC first, then the battery.)
Siemens Industry, Inc.
Building Technologies Division
Florham Park, NJ
Siemens Building Technologies, Ltd.
Fire Safety & Security Products
2 Kenview Boulevard
Brampton, Ontario
L6T 5E4 Canada
1ELBAT SROTCETEDELBITAPMOC
rotceteD
ytitnauQ rep pooLesaB
noitallatsnI snoitcurtsnI .oNtraP
H3/3-ID03S3-BD81-34918
0-513
H3A/3A-ID03S3-BD81-349180-513
H3B/3B-ID03I3-DA6-432390-513
531-P3-TD02S3-BD5-104480-513
11-TD0311-BD htiwS3-BD T
PDA-BD
3-924590-513 3-924590-513
1911-ABP11911-BBP3-424590-513
T3/3-EP03S3-DA PLI3-DA 7-578090-513 6-432390-513
T1
1/11-EP0311-BD htiwS3-BD TPDA-BD
9-891490-513 9-891490-513
Figure 2
SZE-4X Wiring Diagram
Figure 3
Smoke Detector and Shorting Type Device
Wiring Diagram
NOTES:
1. The SXL-EX Control Panel meets NFPA 72
Local requirements.
2. All field wiring must be in accordance with
NFPA 70, Article 760.
3. Do not make any wiring connections
while the System is powered.
4. Form C relay contacts are shown de-
energized. They are not suitable for motor
or pilot duty.
5. Combined current output for NAC1, NAC2,
and auxiliary outputs is limited to 3.0 amps.
6. Equipment connected to these terminals
must be located within the same room.
7. In all cases the Siemens Industry, Inc.,
Model Number is the compatibility
identifier, including the Control Panel,
Module(s), and all Compatible Initiating
Devices.
4X
4X
Figure 4
PB-1191 Device Wiring Diagram
UL Listed EOL Device
3.9K, 1/2W, P/N 140-820386
(IDCs Supervised)
Class B (Style B)
UL Listed EOL Device
3.9K, 1/2W, P/N 140-820386
(IDCs Supervised)
Class B (Style B)
+ -
+ -
+ -
+ -
+ -
+ -
+ -
+ -
IDC 5
IDC 5
IDC 6
IDC 6
IDC 7
IDC 7
IDC 8
IDC 8
TB-3
TB-1
TB-2
To JP3
of SXL-EX
Main
Board
To JP3
of SXL-EX
Main
Board
JP1
FORM C
RELAY 1
FORM C
RELAY 1
(See
Note 6)
(See
Note 6)
(See Note 6)
(See Note 6)
(See
Note 6)
(See
Note 6)
(See
Note 6)
(See
Note 6)
(See
Note 6)
(See
Note 6)
FORM C
RELAY 2
FORM C
RELAY 2
FORM C
RELAY 3
FORM C
RELAY 3
FORM C
RELAY 4
FORM C
RELAY 4
OC 1 Programmable
OC 1Programmable
External
Load
External
Load
External
Load
External
Load
External
Load
External
Load
External
Load
External
Load
To External +24VDC
UL Listed, Regulated,
and Filtered power
supply.
To External +24VDC
UL Listed, Regulated,
and Filtered power
supply.
To SXL-EX
Main Board
-V TB-3
To SXL-EX
Main Board
-V TB-3
If External
Power Supply
is not available,
connect to
SXL-EX Main
Board
+24V TB-3.
(See Note 5)
If External
Power Supply
is not available,
connect to
SXL-EX Main
Board
+24V TB-3.
(See Note 5)
See Open Collector Electrical Rating Table
and Note 6
See Open Collector Electrical Rating Table
and Note 6
+
-
SZE-4X
OC 2 Programmable
OC 2Programmable
OC 3 Programmable
OC 3Programmable
OC 4 Programmable
OC 4Programmable
Programmable Programmable Programmable Programmable
See COMPATIBLE DETECTOR CHART and
INITIATING DEVICE CIRCUIT ELECTRICAL RATINGS
See COMPATIBLE DETECTOR CHART and
INITIATING DEVICE CIRCUIT ELECTRICAL RATINGS
Postive and Negative Ground Fault
Detected at <100K for Terminals on TB-3
Postive and Negative Ground Fault
Detected at <100K for Terminals on TB-3
PBA-1191 Device Wiring Diagram
TO IDC
ZONE
TO IDC
ZONE
-
-
- -
+
+
+ +
EOL RESISTOR
4.7K, 1/4W, P/N 140-820188
EOL RESISTOR
4.7K, 1/4W, P/N 140-820188
PBA-1191
A B CDEF
DO NOT
USE
DO NOT
USE
P/N 315-096018-8
INITIATING DEVICE CIRCUIT
Electrical Ratings
Voltage range: 18.2-26.8 VDC filtered
Supervisory current: 6mA
Alarm current: 120mA (max)
1. Maximum line impedance of 25 ohms
per IDC zone.
2. All IDC zones are supervised and power
limited per NFPA 70, Article 760.
3. Each IDC zone must use at least 18
AWG, 300V insulation, color-coded wire
for low voltage circuits where local
codes require conduit. Where local
codes permit, use limited energy
shielded cable rated at 300V.
4. Each IDC zone supports one initiating
device in alarm.
5. Maximum line capacitance is 10uF per
zone.
Figure 1
Mounting the SZE-4X Module
OPEN COLLECTOR
ELECTRICAL RATING TABLE
50mA (max) at 26.4 VDC (max)
Resistive Only
FORM C
RELAY ELECTRICAL RATINGS
2A at 30 VDC
200mA at 120 VAC Resistive Only

Other Siemens Control Unit manuals

Siemens Simatic S7-1500/ET 200MP User manual

Siemens

Siemens Simatic S7-1500/ET 200MP User manual

Siemens SIMATIC User manual

Siemens

Siemens SIMATIC User manual

Siemens SINUMERIK 840Di Manual

Siemens

Siemens SINUMERIK 840Di Manual

Siemens SIMOTION D4 Series Technical Document

Siemens

Siemens SIMOTION D4 Series Technical Document

Siemens 545-714 User manual

Siemens

Siemens 545-714 User manual

Siemens MLC User manual

Siemens

Siemens MLC User manual

Siemens SIMATIC S5 User manual

Siemens

Siemens SIMATIC S5 User manual

Siemens HTRI-S User manual

Siemens

Siemens HTRI-S User manual

Siemens AS-Interface ASIsafe 3RK1205-0B.00-2AA2 User manual

Siemens

Siemens AS-Interface ASIsafe 3RK1205-0B.00-2AA2 User manual

Siemens SIMATIC ET 200SP User manual

Siemens

Siemens SIMATIC ET 200SP User manual

Siemens CLM Series Guide

Siemens

Siemens CLM Series Guide

Siemens Climatix POL822 User manual

Siemens

Siemens Climatix POL822 User manual

Siemens SI120 Instruction sheet

Siemens

Siemens SI120 Instruction sheet

Siemens HiPath optiPoint 410 Instruction Manual

Siemens

Siemens HiPath optiPoint 410 Instruction Manual

Siemens SINAMICS G110M User manual

Siemens

Siemens SINAMICS G110M User manual

Siemens SIMATIC ET 200SP User manual

Siemens

Siemens SIMATIC ET 200SP User manual

Siemens SINUMERIK 808D Installation guide

Siemens

Siemens SINUMERIK 808D Installation guide

Siemens Sinumerik 840DiE sl User manual

Siemens

Siemens Sinumerik 840DiE sl User manual

Siemens SINUMERIK MC Quick start guide

Siemens

Siemens SINUMERIK MC Quick start guide

Siemens SINAMIC G130 User manual

Siemens

Siemens SINAMIC G130 User manual

Siemens SIMATIC S7-1200 Parts list manual

Siemens

Siemens SIMATIC S7-1200 Parts list manual

Siemens SIRIUS 3RT1.4.-1 User manual

Siemens

Siemens SIRIUS 3RT1.4.-1 User manual

Siemens SIMATIC CPU 410 User guide

Siemens

Siemens SIMATIC CPU 410 User guide

Siemens SINAMICS S120 Technical Document

Siemens

Siemens SINAMICS S120 Technical Document

Popular Control Unit manuals by other brands

NAiS FP Series user manual

NAiS

NAiS FP Series user manual

THORLABS LDM405 user guide

THORLABS

THORLABS LDM405 user guide

VALCOBABY MCP-25 manual

VALCOBABY

VALCOBABY MCP-25 manual

National Instruments NI-9244 User manual and specifications

National Instruments

National Instruments NI-9244 User manual and specifications

GEM 534 Installation, Operating and Maintenance Instruction

GEM

GEM 534 Installation, Operating and Maintenance Instruction

Klark Teknik DN32-DANTE quick start guide

Klark Teknik

Klark Teknik DN32-DANTE quick start guide

Worx WA0863 manual

Worx

Worx WA0863 manual

Sony LLC-8000A Service manual

Sony

Sony LLC-8000A Service manual

Allen-Bradley Series B user manual

Allen-Bradley

Allen-Bradley Series B user manual

Ossur Icelock Alloy 4-Hole 674 Instructions for use

Ossur

Ossur Icelock Alloy 4-Hole 674 Instructions for use

ARCA ECOTROL 8C D Series Operating and maintenance manual

ARCA

ARCA ECOTROL 8C D Series Operating and maintenance manual

Samson 3510 Mounting and operating instructions

Samson

Samson 3510 Mounting and operating instructions

Definox DPAX GEN 2 Maintenance manual

Definox

Definox DPAX GEN 2 Maintenance manual

Icop VEX2-DIP168 user manual

Icop

Icop VEX2-DIP168 user manual

Telit Wireless Solutions UE910 series Hardware user's guide

Telit Wireless Solutions

Telit Wireless Solutions UE910 series Hardware user's guide

Beehive International DM3270 Technical  user's manual

Beehive International

Beehive International DM3270 Technical user's manual

Grundfos RSL instructions

Grundfos

Grundfos RSL instructions

Festo CPX-E-1CI Instructions for use

Festo

Festo CPX-E-1CI Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.