SIIG AV-GM06Y3-S1 User manual

8x8 DVI Matrix
User Manual
P/N: AV-GM06Y3-S1

Safety and Notice
The AV-GM06Y3-S1 8x8 DVI Matrix has been tested for conformance to safety regulations and
requirements, and has been certified for international use. However, like all electronic
equipments, the AV-GM06Y3-S1 should be used with care. Please read and follow the safety
instructions to protect yourself from possible injury and to minimize the risk of damage to the
unit.
●Follow all instructions and warnings marked on this unit.
●Do not attempt to service this unit yourself, except where explained in this manual.
●Provide proper ventilation and air circulation and do not use near water.
●Keep objects that might damage the device and assure that the placement of this unit is on a
stable surface.
●Use only the power adapter and power cords and connection cables designed for this unit.
●Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the
device before cleaning.
TABLE OF CONTENTS
INTRODUCTION.................................................................................................................1
FEATURES.........................................................................................................................1
PACKAGE CONTENTS......................................................................................................1
SPECIFICATIONS..............................................................................................................2
PANEL DESCRIPTIONS.....................................................................................................4
CONNECTION DIAGRAM ..................................................................................................5
HARDWARE INSTALLATION.............................................................................................5
DIP SWITCH.......................................................................................................................6
CHANNEL CONTROL ........................................................................................................8
WARRANTY .....................................................................................................................15

1
INTRODUCTION
The AV-GM06Y3-S1 8x8 DVI Matrix provides the most flexible and cost effective solution in the
market to route high definition video sources from any of the eight DVI sources to the any eight
digital displays at the same time. This solution is well suited for digital signage, conference room
presentation systems, or other similar setting or application.
FEATURES
DVI 1.0 compatible (single link)
Allows any source to be displayed on multiple displays at the same time
Allows any DVI display to view any DVI source at any time
Supports default EDID and learns the EDID of displays
The matrix master unit can switch every output channels to any DVI input via push button, IR
remote control, RS-232 control or Ethernet control.
Easy installation with rack-mounting
Fast response time –2~5 seconds for channel switch
Not HDCP compliant
PACKAGE CONTENTS
●1x AV-GM06Y3-S1
●1x IR Remote control
●2x Rack-mounting ears set
●1x User Manual

2
SPECIFICATIONS
Model Name
AV-GM06Y3-S1
Technical
Role of usage
True 8x8 matrix switcher
DVI compliance
DVI 1.0
Video bandwidth
[AV-GM06Y3-S1] –Single-link 165MHz [4.95Gbps]
Video support
VGA(640x480)~WUXGA (1920x1200),480p~1080p
ESD protection
[1] Human body model —±19kV [air-gap discharge] & ±12kV [contact
discharge]
[2] Core chipset —±2kV
PCB stack-up
4-layer board [impedance control —differential 100Ω; single 50Ω]
Input
8x DVI + 1x RS-232 + 1x Ethernet
Output
8x DVI
Input selection
Push button / IR remote / RS-232 / Ethernet
IR remote control
Electro-optical characteristics: τ = 25° / Carrier frequency: 36~40kHz
DVI connector
Type DVI-I [29-pin female]
RS-232 connector
DE-9 [9-pin D-sub female]
DIP switch
[SW Main] 4-pin operation mode & firmware update
Mechanical
Housing
Metal enclosure
Dimensions
[H x W x D]
Model
1RU-440 x 200 x 44mm [1’5” x 7.9” x 1.7”]
Package
530 x 212 x 158mm [1’9” x 8.3” x 6.2”]
Carton
543 x 335 x 344mm
Weight
Model
2673g [5.9 lbs]
Package
4000g [8.8 lbs]
Fixedness
1RU rack-mount with ears and wall hanging holes
Power supply
AC Power 100-240V
Power consumption
60 Watts [max]
Operation
temperature
0~40°C [32~104°F]
Storage temperature
-20~60°C [-4~140°F]
Relative humidity
20~90% RH [no condensation]

3
USB or RS-232 control must be connected either one at a time. Connecting both types of
cables may cause command confusion.

4
PANEL DESCRIPTIONS
Front Panel
1. Power: Power control
2.Seven Segment LED Indicators: Control display
3.Push button: Front panel push buttons used to select the number of input source and display
channel
4.IR SENSOR: IR sensor for receiving the IR commands from the IR remote
5. Ext. IR: IR receiver
Rear Panel
6.RS-232: RS-232 control port
7.DVI-D INPUT 1 –8: DVI inputs
8.DVI-D OUPUT 1–8: DVI outputs for each output channel
9.AC Power: DC 12V
10.SW Main: DIP switches
(see DIP Switch section)
11.ETHERNET

5
CONNECTION DIAGRAM
HARDWARE INSTALLATION
AV-GM06Y3-S1
1. Connect all sources to DVI Inputs on the 8x8 DVI Matrix
2. Connect all outputs to DVI devices
3. Connect the power cord to the 8x8 DVI Matrix
4. Power on the 8x8 DVI Matrix AV-GM06Y3-S1

6
DIP SWITCH
The AV-GM06Y3-S1 has a built-in EDID profiles designed to cover most of the widely used
resolutions for the ease of installation.
Default EDID
Native/preferred timing: 1680 x 1050p at 60Hz (16:9)
Detailed timing #1: 1920 x 1200p at 60Hz (16:9)
Standard timings supported:
1920 x 1080p at 60Hz 1152 x 870p at 75Hz
1600 x 1200p at 60Hz 1152 x 864p at 75Hz
1440 x 900p at 60Hz 1024 x 768p at 60Hz, 70Hz, 75Hz, 87Hz
1360 x 765p at 60Hz 800 x 600p at 56Hz, 60Hz, 72Hz, 75Hz
1280 x 1024p at 60Hz, 75Hz 720 x 400p at 70Hz
1280 x 960p at 60Hz 640 x 480p at 60Hz, 67Hz, 72Hz, 75Hz
1280 x 800p at 60Hz
Learning EDID from front panel
The EDID learning function is only necessary whenever you encounter any display on the DVI output
port that cannot play video properly. Because the DVI source devices and displays may have various
level of capability in playing video, the general principle is that the source device will output the
lowest standards in video resolutions to be commonly acceptable among all DVI displays. In this
case, a 1024x768 output would probably be the safest choice. Nevertheless, the user can force the
router to learn the EDID of the lowest capable DVI display among others to make sure all displays
are capable to play the DVI signals normally by performing the procedures from the front panel of
AV-GM06Y3-S1:
1. Select the desired Output Port and Input Channel that the EDID of the display connected to this
specified output port can be learned for the specified input channel.
2. Press the “” button of the Output Port and “▬” button of the Input Channel at the same time
for 2 seconds.
3. Release these two buttons. The EDID of the display connected to the chosen output will be
written to the chosen input.
4. If the operation is successful, the LED of Input Channel will show (OK). If the operation is
not successful, it will show (failure).
If the user wants to restore the default EDID profile to any specified input, please follow the steps:
1. Select the desired input that needs to restore the default EDID profile matching the LED on the
Output Port (not Input Channel!).
2. Press the “” button of the Output Port and the “” button of the Input Channel at the same
time for 2 seconds.
3. Release these two buttons. The default EDID profile will be restored to the input port selected
and display on the LED of Output Port. If the operation is successful, the LED of Input Channel
will show (OK). If the operation is not successful, it will show (failure).

7
SW MAIN for firmware update (for technical support only)
DIP Switch Position
Pin#1
Pin#2
Pin#3
Pin#4
Normal Operation Mode [via RS-232 port] 1
OFF [ ]
OFF [ ]
ON [ ]
OFF [ ]
Firmware Update Mode 2
Block A [main]
ON [ ]
OFF [ ]
ON [ ]
OFF [ ]
Block B [remote]
ON [ ]
ON [ ]
ON [ ]
OFF [ ]
Note
1Factory default for SW Main is pin#1-OFF [], pin#2-OFF [], pin#3- ON [], & pin#4-OFF [].
PLEASE MAINTAIN THIS SETTING AT ANYTIME FOR REGULAR USE!
2Sequence for firmware update
WARNING!
[Firmware update only can be done via RS-232 port and connection to PC set at COM1)
1. Power off the AV-GM06Y3-S1. Execute the firmware update program on your PC via COM1
port connection to the RS-232 port of the AV-GM06Y3-S1.
2. Set the pin#1 and pin#3 of [SW Main] at ON []for firmware update mode.
3. Set pin#2 at respective positions to assign which Block to be updated.
4. Power on the AV-GM06Y3-S1. The firmware update program should begin this update sequence
automatically. If not, please check the RS-232 connection status between PC and
AV-GM06Y3-S1.
5. After the OK message shows up to indicate the firmware update sequence for designated
Block is complete, please turn off the AV-GM06Y3-S1.
6. Repeat step 3 ~ step 6 if you want to update the firmware of the remaining Blocks.
7. Set the [SW Main] switch position to Normal Operation Mode.
8. Power on the AV-GM06Y3-S1.

8
CHANNEL CONTROL
Method A: Push Button
1. Use the “+”or “-”channel button on output port to select which port to be changed.
“+”: change selected output port in ascending order
“-”: change selected output port in descending order
2. Push the “+”or “-”channel button on Input channel to select the HDMI input source
you want to display on this selected output port in step 1 in sequential order. Once
you reach the desired input channel you want to display on this selected output port,
leave it and the setting will be effective in a few seconds.
Method B: IR Remote Control
Firstly please push one of the INPUT buttons to choose which HDMI input source you are
going to setup. After that, you can have multiple outputs playing the same content from
the selected INPUT #1 - #8 by pushing the corresponding OUTPUT buttons. The setting
will be effective in a couple of seconds.
INPUT & OUTPUT MAPPING
INPUT 1
HDMI input port #1
INPUT 2
HDMI input port #2
INPUT 3
HDMI input port #3
INPUT 4
HDMI input port #4
INPUT 5
HDMI input port #5
INPUT 6
HDMI input port #6
INPUT 7
HDMI input port #7
INPUT 8
HDMI input port #8
OUTPUT 1
HDMI output port #1
OUTPUT 2
HDMI output port #2
OUTPUT 3
HDMI output port #3
OUTPUT 4
HDMI output port #4
OUTPUT 5
HDMI output port #5
OUTPUT 6
HDMI output port #6
OUTPUT 7
HDMI output port #7

9
OUTPUT 8
HDMI output port #8
FUNCTION KEY
FN +SOURCE SEL. 1
Escape System LOCK
FN +SOURCE SEL. 2
Enter System LOCK (most buttons, IR control, and RS-232 control
become inactive, except Escape System LOCK command )
Method C: Software Control through RS-232 or Ethernet
Using the control software located on the included software CD, it is possible to fully
control the matrix switch by either RS-232 or Ethernet connection.
There are three primary sections of the control software interface: the toolbar at the top,
the input selection area on the left and the output selection area on the right. The input
and output selections are intuitive. The Toolbar details are explained below.
Input Selection Area
Output Selection Area
Toolbar Menu

10
Setting
The “Setting” button brings up the communication configuration menu with the following
controls:
The “Get” button reads the connected device’s ID number.
The “Set” button assigns a new device ID number to the
connected device.
The “Rename” button opens up the String Table menu which
allows you to assign custom names to inputs and outputs
within the software.
The “Ethernet” section allows the user to read and write
Ethernet settings from/to the unit. Ethernet setting changes
must be made while under RS-232 control. Select the “Write
To Device” button to store your setting changes.
The “Communication” section allows the user to select
between RS-232 and Ethernet control.
Note: After making changes to the Ethernet settings the user must power cycle the unit
for the new settings to become effective. If the unit receives commands from both
Ethernet and RS-232 ports at the same time the Ethernet commands will have
priority.
Scan
The “Scan” button brings up the Serial Port Scan menu which
allows the user to scan the computer’s COM ports for connected
units.
The “Select” section allows you to manually select the COM
port and Device ID of the unit you wish to control.
The “Scan” button will cause the software to scan all
available COM ports and display which ports have
connected devices.
After you have selected the device you wish to control,
click on “OK” to finalize your selection.
Note: Selecting Device ID 255(Super) will cause the software to send commands that will
affect units with any Device ID on the selected COM port.

11
Linkage
The “Linkage” button will cause the software to re-read the active Input and Output routes
on the matrix switch. You may need to use this if you have made changes to the matrix
switch by some method other than the control software.
Open/Close
The “Open” and “Close” buttons are used to open and close the COM port or Ethernet
connection to the matrix switch.
Mapping
The “Mapping” button provides an alternate method
for selecting the Outputs you wish to begin
connecting your Input to.
Choose the “Select All Output” menu item
then select an Input from the Input Selection
Area on the left side to send that Input to all
Outputs.
Choose the “Unselect All Output” menu item
to de-select all currently selected Outputs
from the currently selected Input.
Choose one of the “Select Input n” menu
items to make that Input your active input.
Then select all of the Outputs you wish to
send that Input to from the list of Outputs in
the Output Selection Area on the right side.
Fast Select
The “Fast Select” drop down allows you to quickly
route single Inputs to single Outputs (1:1
mapping) or a single Input to all Outputs.
Choose the “Input Num - Output Num”
menu item to set each Input to route to the
Output of the same number. (Input 1 to
Output 1, Input 2 to Output 2, etc.)
Choose one of the “Input n - All Output”
menu items to send the selected Input to all
Outputs.

12
Direct Input/Output Selection Area
It is also possible to directly select Inputs and Outputs using the buttons and drop down
menus located in the Input and Output Selection Areas to the left and right.
To directly send an input to an output, open up the drop down menu to the right of
the Output and select the Input to route to it. The connection line will move to
indicate the new route.
To route an Input to more than one Output, select the Outputs you wish to affect in
the Output Selection Area on the right (each button will turn grey to indicate it is
selected). After you have selected all of the Outputs you wish to affect, select the
Input you wish to send to those Outputs from the buttons in the Input Selection Area
on the left. The connection lines will move to indicate the new routes.

13
Command Set:
COMMAND
ACTION
COMMAND
ACTION
ST
System Status
VR
Firmware Version
A1
Output A selects Input 1
E1
Output E selects Input 1
A2
Output A selects Input 2
E2
Output E selects Input 2
A3
Output A selects Input 3
E3
Output E selects Input 3
A4
Output A selects Input 4
E4
Output E selects Input 4
A5
Output A selects Input 5
E5
Output E selects Input 5
A6
Output A selects Input 6
E6
Output E selects Input 6
A7
Output A selects Input 7
E7
Output E selects Input 7
A8
Output A selects Input 8
E8
Output E selects Input 8
B1
Output B selects Input 1
F1
Output F selects Input 1
B2
Output B selects Input 2
F2
Output F selects Input 2
B3
Output B selects Input 3
F3
Output F selects Input 3
B4
Output B selects Input 4
F4
Output F selects Input 4
B5
Output B selects Input 5
F5
Output F selects Input 5
B6
Output B selects Input 6
F6
Output F selects Input 6
B7
Output B selects Input 7
F7
Output F selects Input 7
B8
Output B selects Input 8
F8
Output F selects Input 8
C1
Output C selects Input 1
G1
Output G selects Input 1
C2
Output C selects Input 2
G2
Output G selects Input 2
C3
Output C selects Input 3
G3
Output G selects Input 3
C4
Output C selects Input 4
G4
Output G selects Input 4
C5
Output C selects Input 5
G5
Output G selects Input 5
C6
Output C selects Input 6
G6
Output G selects Input 6
C7
Output C selects Input 7
G7
Output G selects Input 7
C8
Output C selects Input 8
G8
Output G selects Input 8
D1
Output D selects Input 1
H1
Output H selects Input 1
D2
Output D selects Input 2
H2
Output H selects Input 2
D3
Output D selects Input 3
H3
Output H selects Input 3
D4
Output D selects Input 4
H4
Output H selects Input 4
D5
Output D selects Input 5
H5
Output H selects Input 5
D6
Output D selects Input 6
H6
Output H selects Input 6

14
D7
Output D selects Input 7
H7
Output H selects Input 7
D8
Output D selects Input 8
H8
Output H selects Input 8

15
WARRANTY
The SELLER warrants the AV-GM06Y3-S1 8x8 DVI Matrix to be free from defects in the
material and workmanship for 3 years from the date of purchase from the SELLER or an authorized
dealer. Should this product fail to be in good working order within 3 years warranty period, the
SELLER, at its option, repair or replace the unit, provided that the unit has not been subjected to
accident, disaster, abuse or any unauthorized modifications including static discharge and power
surge. This warranty is offered by the SELLER for its BUYER with direct transaction only. This
warranty is void if the warranty seal on the metal housing is broken.
Unit that fails under conditions other than those covered will be repaired at the current price of
parts and labor in effect at the time of repair. Such repairs are warranted for 90 days from the day
of reshipment to the BUYER. If the unit is delivered by mail, customers agree to insure the unit or
assume the risk of loss or damage in transit. Under no circumstances will a unit be accepted
without a return authorization number.
The warranty is in lieu of all other warranties expressed or implied, including without
limitations, any other implied warranty or fitness or merchantability for any particular purpose, all
of which are expressly disclaimed.
Proof of sale may be required in order to claim warranty. Customers outside Taiwan are
responsible for shipping charges to and from the SELLER. Cables and power adapters are limited to
a 30 day warranty and must be free from any markings, scratches, and neatly coiled.
The content of this manual has been carefully checked and is believed to be accurate. However,
The SELLER assumes no responsibility for any inaccuracies that may be contained in this manual.
The SELLER will NOT be liable for direct, indirect, incidental, special, or consequential damages
resulting from any defect or omission in this manual, even if advised of the possibility of such
damages. Also, the technical information contained herein regarding the AV-GM06Y3-S1 features
and specifications is subject to change without further notice.
April, 2018
Support
For more info or tech support
http://www.siig.com/support
Table of contents
Other SIIG Matrix Switcher manuals

SIIG
SIIG AV-GM0783-S1 User manual

SIIG
SIIG AV-GM0703-S1 User manual

SIIG
SIIG CE-H24W11-S1 User manual

SIIG
SIIG AV-GM08G3-S1 User manual

SIIG
SIIG AV-GM07N3-S1 User manual

SIIG
SIIG AV-GM0803-S1 User manual

SIIG
SIIG AV-GM07C3-S1 User manual

SIIG
SIIG AV-GM08F3-S1 User manual

SIIG
SIIG AV-GM0843-S1 User manual

SIIG
SIIG CE-H21F11-S1 User manual

SIIG
SIIG AV-GM0743-S1 User manual

SIIG
SIIG CE-H27Q11-S1 User manual

SIIG
SIIG AV-GM07M3-S1 User manual

SIIG
SIIG AV-GM0733-S1 User manual

SIIG
SIIG AV-GM07U3-S1 User manual

SIIG
SIIG AV-GM0823-S1 User manual

SIIG
SIIG AV-GM07R3-S12 User manual

SIIG
SIIG AV-GM06X3-S1 User manual

SIIG
SIIG MA-1088D User manual

SIIG
SIIG CE-H23H11-S1 User manual