Repair Parts and Maintenance Guide
140
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
As the user’s hands enter the
beam’s effective range, the beam
is reected back into the sensor
receiver and activates the solenoid
valve allowing water to ow from
the faucet. Water will ow until
the hands are removed or until the
faucet reaches its automatic time
out limit setting.
OPERATION
SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP
Adjust lever to set temperature.
OPTIONAL – To x temperature,
set lever to the desired position,
then remove lever and plug hole
with cap.
2.5 mm
Faucet may be adjusted in 10º
increments.
2.5 mm
This feature will operate the faucet
every 12 or 24 hours since last
use, if not used to prevent stagnant
water conditions.
Default purge duration is two
minutes.
Consult factory regarding other
timing options.
IR activation (see above). Cover IR
clic approximately 24 sec. (ignore
LED indications during this period).
Release when requested program
is reached. (See diagram to right).
Programming mode will time out
after 2 minutes if no changes are
made.
12/24 LINE PURGE FEATURE
1x 24 sec
+ ...
Activate 12HR
Deactivate
Activate 24HR
...1x
...2x
...3x
Activate 12HR
Deactivate
Activate 24HR
Optional Hot Limit Stop Adjustment
– To adjust the hot/cold mix (factory
set at 50/50) remove the lever.
Check to make sure dot is in
center position before beginning
adjustment.
2.5 mm
Steps to Default IR
Function Activate Function Setting Clic
IR Activation Cover IR clic approximately for 2 sec. –– ––
until LED will ash GREEN 1x - then remove
nger from IR clic (Active for 5 sec.)
Cleaning IR activation; Cover IR clic 2x - conrmation 2 min. ––
Mode of the function is active by a couple ashes
by the LED; to return to normal operation cover
IR clic 1x or the faucet will automatically return
to normal function after 2 min.
12/24 Line See below. Off Off
Purge 12HR
Feature 24HR
Sensor See page 130. 6 1-8
Range
Adjustment
Reset IR activation; Cover IR clic 2x; LED will ash 5x Manually ––
Electronics Cover IR clic 1x for 5 sec. until LED
ashes 4x, then remove nger from IR clic
Wait for 20 sec.
(After 10 sec. water will ow for 6 sec.
and automatically adjust to environment)
Security Off After 90 seconds (max) of hand and/or object On ––
within sensor appears permanent, waterow
will stop and will remeasure environment
Please contact factory for more extensive programming options.
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
141 The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will not fall out.
UPGRADE FAUCET FUNCTIONALITY
LED DISPLAY DIAGNOSTIC CODES
Place new crown on faucet by sliding
onto spout and tightening hex screw
on underside of spout.
NOTE: All electronics are fully
encapsulated in the crown
and thus protected from the
environment and easy to replace
or upgrade.
RED GREEN
RED GREEN
RED
RED
RED
RED
RED
GREEN
GREEN
GREEN
RED
RED
RED
RED LED1
GREEN LED2
RED LED3
Function LED1 LED2 LED3 Description 1 Description 2
Start Up Boot LED1 and LED2 alternate blinking Fast Toggle
Battery Check after Start Up LED1 on for 2 sec, if battery greater than 3.5V
Line Power Check after Start Up LED3 on for 2 sec, if line power greater than 3.5V
IR Adjust Process LED1 blinking while IR adjusts Few seconds
IR Adjust IR LED2 on for 2 sec, if adjustment OK
Battery Low LED1 blinks 3x, if battery is less than warning level Only while in detection mode
Battery Empty LED1 double ashes 3x, if battery is
less than empty level Only while in detection mode
Valve Error
LED3 double ashes 3x, if valve
current error; ash after the 3rd error,
off after the 3rd good operation
Flashes after the 3rd error, off
after the 3rd good operation
IR Activation LED2 on for 2 sec, if IR-click has been activated After 5 sec. automatically back to
operating mode
Cleaning Mode LED1 4-in-1 ash, if cleaning mode is activated During “Cleaning Mode” is activated
Permanent 4-in-1 ashes
COLOR LEDs BLINKING
COLOR LEDs ON
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 138 9/18/17 7:53 AM