Note 1) Based on JIS B 8374-1981 (Supply pressure: 0.5 MPa; with light/surge voltage suppressor: clean air)
Response time values will change depending on pressure and air quality.
Note 2) Weight for threaded connection
Valve construction
Fluid
Max. operating pressure (MPa)
Min. operating pressure (MPa)
Ambient and fluid temperature (°C)
Max. operating frequency (Hz)
Pilot exhaust method
Lubrication
Manual override
Mounting orientation
Impact/Vibration resistance (m/s
2
) Note 2)
Enclosure∗
Metal seal
20
0.7 (High pressure type: 1.0)
0.1
0.7
0.15
0.7 (High pressure type: 1.0)
0.15
Rubber seal
5
Not required
Push type, Locking type (Tool required)
Free
150/30
Dustproof (DIN terminal: IP65 Note 3))
VQZ100 (Poppet seal)
20
Common exhaust
Note 1)
Air, Inert gas
Individual exhaust
–10 to 50 (No freezing)
∗In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
Solenoid Specifications
Flow Characteristics
Semi-standard Specifications
High speed response type
High pressure type (Metal seal type only)
External pilot type∗
∗For details on external pilot type, refer to page 1806.
Symbol Description
Pilot valve common exhaust
Main valve fluororubber
All fluororubber
X30
X90
X113
Series
Valve
construc-
tion
Poppet
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
N.C. valve
VQZ100
N.C.
valve
N.O.
valve
N.C.
valve
N.O.
valve
VQZ200
VQZ300
Model
VQZ115
VQZ212
VQZ232
VQZ222
VQZ242
VQZ312
VQZ332
VQZ322
VQZ342
Weight
(g)
Response time (ms) Note 1)
2 →3 (A →R)1 →2 (P →A)
Flow characteristics
0.59
1.2
1.6
1.2
1.6
2.7
3.5
2.6
3.5
0.44
0.21
0.33
0.25
0.36
0.18
0.34
0.21
0.38
0.17
0.30
0.39
0.31
0.40
0.62
0.87
0.59
0.88
Standard:
0.35 W
High
pressure:
0.9 W
High
speed
response:
0.9 W
AC
24
57
93
Note 2)
0.56
1.3
1.7
1.3
1.7
2.4
3.0
2.2
2.9
0.30
0.24
0.37
0.20
0.36
0.28
0.33
0.16
0.27
0.14
0.33
0.45
0.31
0.45
0.56
0.72
0.49
0.69
C [dm3/(sbar)]
b Cv
C [dm3/(sbar)]
b Cv
10 or less
22 or less
22 or less
22 or less
22 or less
22 or less
33 or less
22 or less
33 or less
13 or less
18 or less
—
18 or less
—
22 or less
—
22 or less
—
—
14 or less
15 or less
14 or less
15 or less
17 or less
25 or less
17 or less
25 or less
22 or less
34 or less
36 or less
34 or less
36 or less
34 or less
57 or less
34 or less
57 or less
Electrical entry
Allowable voltage fluctuation
Surge voltage suppressor
Indicator light
Power
consumption (W)
Coil rated voltage
(V)
Apparent power
(VA)∗
DC
AC
DC
AC 50/60 Hz
G, L, M Y
Grommet (G)
L-type plug connector (L)
M-type plug connector (M)
DIN terminal (Y)
24, 12
100, 110, 200, 220∗
±10% of rated voltage∗
0.35 [(With light: 0.4 (DIN terminal with light: 0.45)]
0.9 [(With light: 0.95 (DIN terminal with light: 1.0)]
Varistor
LED (Neon light when AC with DIN terminal)
0.86 (With light: 0.89)
[0.94 (With light: 0.97)]
0.86 (With light: 0.87)
[0.94 (With light: 1.07)]
0.78 (With light: 0.81) 0.78 (With light: 0.87)
1.18 (With light: 1.22) 1.15 (With light: 1.30)
1.30 (With light: 1.34)
[1.42 (With light: 1.46)]
1.27 (With light: 1.46)
[1.39 (With light: 1.60)]
Standard
High speed
response,
high pressure
100 V
200 V
110 V
[115 V]
220 V
[230 V]
Specifications
∗Based on IEC60529
Note 1) When using body ported type as a single unit, the individual exhaust is used.
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at
the right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Value in the initial state)
Vibration resistance
: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed
to axis and right angle directions of the main valve and armature when pilot signal is ON
and OFF. (Value in the initial state)
Note 3) When IP65 compliant DIN terminals are selected: VQZ 2-YW1-
2
3
Series VQZ100/200/300
Made to Order
(For details, refer to page 1825.)
1794