Before Use
Fieldbus device
EX250-SAS3/EX250-SAS5
EX250-SAS7/EX250-SAS9
NOTE
•When conformity to UL is necessary the SI unit must be used with a UL1310
Class 2 power supply.
•The product is a UL approved product only if it has a mark on the body.
Safety Instructions
Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids.
Fire, malfunction, or damage to the product can result.
Verify the specifications before use.
Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
Do not operate in an atmosphere containing flammable or explosive gases.
Fire or an explosion can result.
This product is not designed to be explosion proof.
If using the product in an interlocking circuit:
•Provide a double interlocking system, for example a mechanical system.
•Check the product regularly for proper operation.
Otherwise malfunction can result, causing an accident.
The following instructions must be followed during maintenance:
•Turn off the power supply.
•Stop the air supply, exhaust the residual pressure and verify that the air is released before performing
maintenance.
Otherwise an injury can result.
Provide grounding to assure the noise resistance of the product.
Individual grounding should be provided close to the product with a short cable.
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or
equipment damage.
These instructions indicate the level of potential hazard with the labels of
"Caution", " Warning" or "Danger". They are all important notes for safety and
must be followed in addition to International standards (ISO/IEC) and other safety
regulations.
Warning
Caution
After maintenance is complete, perform appropriate functional inspections.
Stop operation if the equipment does not function properly.
Safety cannot be assured in the case of unexpected malfunction.
CAUTION indicates a hazard with a low level of risk which, if
not avoided, could result in minor or moderate injury.
Caution:
Warning:
Danger:
WA NING indicates a hazard with a medium level of risk
which, if not avoided, could result in death or serious injury.
DANGE indicates a hazard with a high level of risk which, if
not avoided, will result in death or serious injury.
Operator
This operation manual is intended for those who have knowledge of machinery
using pneumatic equipment, and have sufficient knowledge of assembly,
operation and maintenace of such equipment. Only those persons are allowed
to perform assembly, operation and maintenance.
ead and understand this operation manual carefully before assembling,
operating or providing maintenance to the product.
Thank you for purchasing an SMC EX250-SAS3/EX250-SAS5/EX250-SAS7/
EX250-SAS9 Fieldbus device.
Please read this manual carefully before operating the product and make sure you
understand its capabilities and limitations. Please keep this manual handy for
future reference.
To obtain the operation manual about this product and
control unit, please refer to the SMC website
(U L http://www.smcworld.com) or contact SMC directly.
Summary of Product elements
ADDR1ADDR2
ADDRESSSETTING
PWRAUXIN
-ERR
COM
-ERR
HOLD
CLEAR
SW
1
7
5
6
4
2
Mounting and Installation
Installation
The SI unit does not have mounting holes, so it cannot be installed alone. Make sure to
connect the valve manifold.
efer to the valve catalogue for valve manifold dimensions.
M3 hexagon screw
Tightening torque: 0.6 Nm
Tie-rod
Tightening torque: 0.6 Nm
End plate SI unit Valve manifold
Exchange of SI unit
• emove screws from End Plate and release connection of each unit.
• eplace old SI unit with new one. (Tie-rod does not need to be removed.)
•Connect Input Block and End Plate and tighten removed screws by specified
tightening torque. (0.6 Nm)
Assembly and disconnection of unit
Addition of Input Block
• emove screws from End Plate.
•Mount attached tie-rod.
•Connect additional Input Block.
•Connect End Plate and tighten removed screws by specified tightening torque.
(0.6 Nm)
Caution for maintenance
(1) Be sure to turn-off all power supplies.
(2) Be sure that there is no foreign object in any of units.
(3) Be sure that gasket is lined properly.
(4) Be sure that tightening torque is according to specification.
If these items are not kept, it may lead to the breakage of substrate or intrusion of
liquid or dust into the units.
Connecting cables
Select the appropriate cables to mate with the connectors mounted on the SI unit.
Troubleshooting
Technical documentation giving detailed troubleshooting information can be found on the
SMC website (U L http://www.smcworld.com).
Specifications
Connected load: 24 VDC Solenoid valve with surge voltage suppressor of 1.5 W or less
(manufactured by SMC)
Current consumption of power supply for SI unit operation: 0.1 A max.
Operating ambient temp.: +5 to +45 oC
Storage ambient temp.: -20 to +60 oC
∗1: Input terminal are not isolated from Power source.
∗2: Do not connect outside Power source to Input and Output terminals.
Technical documentation giving detailed specification information can be found on the SMC
website (U L http://www.smcworld.com).
Outline Dimensions
Technical documentation giving detailed outline dimensions information can be found on
the SMC website (U L http://www.smcworld.com).
Assembly and disassembly of the SI unit
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2012-2017 SMC Corporation All ights eserved.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: +81 3-5207-8249 Fax: +81 3-5298-5362
URL http://www.smcworld.com
Communication connector
Element Description
Connect with AS-Interface communication line.
Power supply connector for
output equipment ∗1Supplies power to the solenoid valve and Output block.
Output block connector Connects the solenoid valve, Output block and etc.
Display window LED display shows the SI unit status.
1
No.
2
4
5
∗1: Available only for EX250-SAS3/EX250-SAS5.
Switch protective cover Sets the address and baud rate etc. with the switch inside.
Grounding terminal (FE) ∗1Used for grounding.
6
7
Input block connector Connects the Input block.
3
•Power supply connector for output equipment
24 V
Description Function
Power supply for output equipment (+)
N.C. Unused
0VPower supply for output equipment (
-
)
1
No.
2
3
N.C. Unused4
The M12 cable, AS-i standard cable and connector for T-branch are not supplied by SMC.
Contact each manufacturer for the catalogue details etc.
Wire the cable for AS-Interface line so that the total voltage drop is 3 V or less.
AS
-
i +
Description Function
AS−Interface line (+)
(0 V) Power supply for output equipment (
-
)
AS
-
i
-
AS−Interface line (
-
)
1
No.
2
3
(24 V) Power supply for output equipment (+)
4
•Communication connector
E250-SAS3/E 250-SAS5
∗: Connected inside the SI unit.
Power supply connector
for output equipment
Communication connector
Ground terminal
•Connection example
M12 cable
Recommendation conductor cross-section: 1.5mm2
AS-i standard cable
(BLACK CABLE)
Connector for T-branch
ASI FK M12 Hirschmann etc.
(IEC 603526)
EX250-SAS3 AS-i standard cable
(YELLOW CABLE)
The M12 cable, AS-i standard cable and connector for T-branch are not supplied by SMC.
Contact each manufacturer for the catalogue details etc.
Wire the cable for AS-Interface line so that the total voltage drop is 3 V or less.
AS
-
i +
Description Function
AS−Interface line (+)
(0 V) ESE VE
AS
-
i
-
AS−Interface line (
-
)
1
No.
2
3
(24 V) ESE VE4
•Communication connector
E 250-SAS7/E 250-SAS9
•Connection example
M12 cable
Recommendation conductor cross-section: 1.5mm2
Connector for T-branch
ASI FK M12 Hirschmann etc.
(IEC 603526)
EX250-SAS7 AS-i standard cable
(YELLOW CABLE)
Setting
ADDRESS SETTING
SW
EX250
ADDR2ADDR1
HOLD
CLEAR
COM
-ERR
IN
-ERR
AUXPWR
SI
PW
LED LED condition
Green LED is ON Indicates that the power supply for AS-Interface line is turned ON.
AUX Green LED is ON Indicates that the power supply for
output equipment is turned ON.
IN-E ed LED is ON Indicates that an input power supply over current is detected. ∗1
(LED is OFF at normal condition)
LED Indication
Description
COM-E
ed LED is ON
ed LED is flashing
Indicates a communication error.
(LED is OFF at normal condition)
Indicates peripheral equipment error. ∗1
(Over current of input power, blown fuse)
EX250-SAS3/EX250-SAS5 EX250-SAS7/EX250-SAS9
-
(LED is OFF at normal condition)
∗1: EX250-SAS3/EX250-SAS5: Input block
EX250-SAS7/EX250-SAS9: Input block, Output block, Solenoid valve
Address setting
HOLD/CLEAR setting
Over Current Protection setting SW
Address setting procedure via the AS-i line
To set this function, refer to SMC website (U L http://www.smcworld.com) for more detailed
information or contact us.
Tie-rod (2 pcs.)
Accessory
3
ADDR1ADDR2
ADDRESSSETTING
PWRAUXIN
-ERR
COM
-ERR
HOLD
CLEAR
SW
M12 4-pin plug
M12 4-pin plug ∗
M12 4-pin, plug
EX※※-OMP0021-A