  9. SMC Networks VV100 Series User manual

SMC Networks VV100 Series User manual

3 Port Solenoid Valve
• Connector entry direction
Upward Lateral
Standard
(Same direction as the cylinder
ports)
Side
Plug-in
Connector type manifold Non Plug-in
Individual wiring manifold
2
direct-operated 3-port valves on
1
station
Individually wired valve can be added.
Connector
(For plug-in connection)
SUP/EXH block fittings
ø2 One-touch fitting connection is possible.
• Fitting entry direction
D-sub connector
Number of connectors: 15 pins, 26 pins (for plug-in connection)
Highly Integrated Unit Manifold
CAT.ES11-98A
Series VV100
Compact manifold with
two 3-port valves on 1 station
Bracket mounting example
Straight fitting Elbow fitting
(Upward entry)
Elbow fitting
(Downward entry)
50.3
40L
(5.9)
Stations
L
1
34.2
2
44.4
3
54.6
4
64.8
5
75
6
85.2
7
95.4
8
105.6
9
115.8
10
126
11
136.2
12
146.4
L: Dimensions
Mounting
Piping Variations
• Metric size: ø2, ø4 one-touch fitting
• Inch size: ø1/8", ø5/32" one-touch fitting
Applications
Operating a small bore
size cylinder such as a
pin cylinder
Air-operated valve for
chemical valve
Possible to shut the signal of each valves
individually.
With Switch
• The valve coil is not
energized even if an
electric signal is fed by
the manifold's connec-
tor.
• Effective use as a safe-
ty measure for mainte-
nance.
Switch
ON
OFF
Scale:
100
%
Scale:
100
%
Direct mounting Bracket mounting
4 x M3 x 0.5
Features 1
INDEX
Common Specifications
Construction
P.2
P.3
Connector Type Manifold
How to Order
Manifold Electrical Wiring
Connector Wiring Diagram
Dimensions
P.4, 5
P.6
P.6
P.7 to 11
Individual Wiring Manifold
How to Order
Dimensions
P.12, 13
P.14, 15
Manifold Exploded View
Manifold Options
Safety Instructions
Specific Product Precautions
P.16
P.17 to 19
Back page 1, 2
Back page 3 to 7
Plug-in
Non Plug-in
1
Manifold Specifications
Response Time
Solenoid Valve Specifications
Fluid Air
0 to 0.7
1 port: –100 kPa to 0.6/3 ports: –100 kPa to 0
1 port: –100 kPa to 0/3 ports: –100 kPa to 0.6
–10 to 50 (No freezing)
20
Not required
Unrestricted
150/30
Dustproof
24 VDC, 12 VDC
±10% of rated voltage Note 2)
0.4
0.15
Diode
LED
Operating pressure
range (MPa)
Ambient and fluid temperature (°C)
Maximum operating frequency (Hz)
Lubrication
Mounting orientation
Shock/Vibration resistance (m/s2) Note 1)
Enclosure
Coil rated voltage
Allowable voltage fluctuation
Surge voltage suppressor
Indicator light
Power
consumption
(W)
Positive pressure
N.C.
N.O.
Vacuum
pressure
Standard
With power saving circuit
(Continuous duty type)
Note 1) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and
at the right angles to the main valve and armature in both energized and de-energ-
ized states every once for each condition. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000Hz. Test was per-
formed in the axial direction and at the right angles to the main valve and armature in
both energized and de-energized states for each condition. (Value in the initial state)
Note 2) For the allowable voltage fluctuation for Z and T types (with power saving circuit), observe the following
range because there is voltage drop due to internal circuit.
Response time ms (at 0.5 MPa)
7 or less
Mass
Valve model
V110-C2/C4
Number of solenoids
1 pc. (Single)
2 pcs. (Double)
Port size
C2, C4
(ø2, ø4 one-touch fitting)
Mass (g)
31
40
Flow Characteristics
Port size
1(P)
C6
2a, 2b 1(P)→2a/2b
C [dm3/(s·bar)] C [dm3/(s·bar)]
2a/2b→3(E)
C2
C4
0.03
0.03
0.22
0.19
0.05
0.05
0.31
0.29
bb
Flow characteristics
Model D-sub connector
Type 10FA
Connector type
1 to 12 stations
Individual wiring
Non-polar, +COM +COM
Common SUP, EXH
Valve
Side, Upward, Downward (Using elbow fittings for upward or downward)
C4, C6, N3, N7
C2, C4, N1, N3
W = 56 + n
Type 10FB Type 10
Non plug-in
Manifold type
1 (SUP), 3 (EXH)
Applicable connector
Internal wiring
Mass W (g) n: Valve stations
Location
Direction
1 (SUP), 3 (EXH) port
2a, 2b port
∗The mass W is the value for the manifold only. (It is applied when the SUP/EXH block fitting is straight type.)
The mass of solenoid valve should be added by the number of stations.
∗The effective area S (mm2) is approximately 5 times as large as the sonic conductance (S ≈C x 5).
1 to 12 stations
1 to 12 stations
Valve stations
D-sub connector 15 pins D-sub connector 26 pins
Refer to page 19.
2a, 2b port piping
specification
Port size
Z type 24 VDC: –7% to +10%
12 VDC: –4% to +10%
T type 24 VDC: –5% to +10%
12 VDC: –6% to +10%
Max. 7 stations
if all valves
have double
solenoid.
2
Series VV100
SOL.b
SOL.a
13
2a 2b t
o
r wueyqi!0 !1
!2 !3
2a
31
JIS symbol
(N.C.)
(N.O.)
(N.C.)
(N.O.)
2b2a
31
SOL.a SOL.b
13
2a
!2
!1!0
t
rwuey iq
!3o
t
o
r wueyqi!0 !1
!2 !3
2a
2b
2a
Construction
JIS symbol
1
2
3
4
5
6
7
8
9
10
11
12
DescriptionNo. Material
Component Parts
Body
Cover
Push rod
Armature assembly
Core
Poppet
Return spring
Poppet spring
Coil assembly
Pilot adapter
Port block
Clip
Resin
Stainless steel
Resin
Stainless steel/Resin
Stainless steel
FKM
Stainless steel
Stainless steel
—
Resin
Resin
Stainless steel
13
Port Port size Part no.No.
Replacement Parts
One-touch Fitting (Metric Size)
2a, 2b
ø2 one-touch fitting (Straight)
ø4 one-touch fitting (Straight)
ø2 one-touch fitting (Elbow)
ø4 one-touch fitting (Elbow)
ø2 one-touch fitting (Long elbow)
ø4 one-touch fitting (Long elbow)
ø4 one-touch fitting (Straight)
ø6 one-touch fitting (Straight)
ø4 one-touch fitting (Elbow)
ø6 one-touch fitting (Elbow)
ø4 one-touch fitting (Long elbow)
ø6 one-touch fitting (Long elbow)
KJH02-C1
KJH04-C1
KJL02-C1
KJL04-C1-N
KJW02-C1
KJW04-C1-N
VVQ1000-50A-C4
VVQ1000-50A-C6
SZ3000-73-1A-L4
SZ3000-73-1A-L6
SZ3000-73-2A-L4
SZ3000-73-2A-L6
1(P), 3(E)
13
No.
One-touch Fitting (Inch Size)
2a, 2b
1(P), 3(E)
ø1/8" one-touch fitting (Straight)
ø5/32" one-touch fitting (Straight)
ø5/32" one-touch fitting (Straight)
ø1/4" one-touch fitting (Straight)
KJH01-C1
KJH03-C1
VVQ1000-50A-N3
VVQ1000-50A-N7
Single
Double
Port Port size Part no.
3
3 Port Solenoid Valve
Series VV100
• The valve arrangement is numbered as the 1st station from D side.
• Indicate the valves to be attached below the manifold part number, in order
starting from station 1 as shown in the drawing.
The asterisk denotes the symbol for assembly.
Prefix to the part no. of the solenoid valve, etc.
VV100-10FAD2-05U1-C6 1 set (Manifold part no.)
∗ V110-D5CU-C4 3 sets (Double solenoid part no.)
∗ V110-D5CZJ-C4
1 set (Double solenoid, with switch part no.)
∗ V110-D5MZ-C4
1 set (Double solenoid, individual wiring/
lead wire length 300 mm part no.)
Ordering example (VV100-10FA)
····
·················
················
·················
Series VV100
/D-sub Connector
3 Port Solenoid Valve
Plug-in Connector Type Manifold
How to Order Manifold
D-sub connector type
Number of poles
15
26
Symbol
A
B
Connector block
mounting position: D side
SUP/EXH block
mounting position: U side
Valve stations
A: D-sub connector 15 pins
Note
Up to 14
solenoids
possible.
1 station
12 stations
Symbol Stations
01
12
B: D-sub connector 26 pins
Note
Up to 24
solenoids
possible.
1 station
12 stations
Symbol Stations
01
12
∗
If the mounted valve is N.O., apply pressure to the 3(E) port and exhaust air from the 1(P) port.
SUP/EXH block port size
ø4 one-touch fitting (Straight)
ø6 one-touch fitting (Straight)
ø4 elbow fitting (Upward entry)
ø6 elbow fitting (Upward entry)
ø4 elbow fitting (Downward entry)
ø6 elbow fitting (Downward entry)
C4
C6
L4
L6
B4
B6
One-touch fitting (Metric size)
ø5/32" one-touch fitting (Straight)
ø1/4" one-touch fitting (Straight)
N3
N7
One-touch fitting (Inch size)
SUP/EXH block fitting entry direction
1 2
Standard
(Same direction as
the cylinder
ports)
Side
Mounting option
U 1
VV100 10F C605DA 2
How to Order Valve Manifold Assembly
D side
U side
1
32
Stations
V110-D5MZ-C4 (1 set)
Double solenoid, individual wiring/lead wire length 300 mm (24 VDC)
V110-D5CZJ-C4 (1 set)
Double solenoid (24 VDC)
V110-D5CU-C4 (3 sets)
Double solenoid (24 VDC)
Connector entry direction
1
Upward
2
Lateral
Note) If the mounting option “N” (Mounting nut:
Inch size) is selected, the bracket cannot be
mounted.
F1
With bracket
(Standard)
F2
With bracket
(Port
downward)
Nil
Manifold direct mounting type
Manifold direct mounting type
With mounting nut
M3 x 0.5
With mounting nut
No. 10-32 UNF
(Inch size)
N
Symbol
Mounting
Note)
4
How to Order Valve for Connector Type
Standard V1 1 U0 C4
With switch V1
Note 1) See page 13 for the dedicated non plug-in
individual wiring.
V1 1 Z0 C4
1
5
5M
5
C
CZJ0 C4
Normally closed (N.C.)
Normally open (N.O.)
Type of actuation
1
2
Rated voltage
24 VDC
12 VDC
5
6
Single wiring
Double wiring
Single solenoid
wiring specification
Nil
D
∗ Nil for the double solenoid.
Select this when the unused
numbers to wiring are set. See
page 6 for details.
Individual wiring
[For plug-in mixed mounting] Note 1)
With light/surge voltage suppressor
(Non-polar type)
With light/surge voltage suppressor
(Polar type)
Light/surge voltage suppressor
U
Z
∗When the types with power saving circuit, with
switches, and individual wiring are used, the
non-polar type cannot be selected.
∗“Z” is positive common specification.
Standard
With power saving circuit (Continuous duty type)
Coil specification
Nil
T
∗ Be certain to select “with power saving circuit” when the solenoid
valve will be energized continuously for long periods of time.
∗ Normally closed and normally open
type cannot be mounted on the
same manifold.
Specifications
Number of solenoids
Symbol
1 pc. (Single solenoid)
2 pcs. (Double solenoid)
S
D
T
T
D
D
D
∗Connector entries with the symbol
“M” cannot use the switch signal
from the D-sub connector on the
manifold. For details, refer to Mani-
fold Electrical Wiring on page 6.
∗When ordering a connector assem-
bly separately, see back pages 6
and 7.
Connector entry
C: Dedicated for centralized wiring
M: Individual wiring, With lead wire
Length 300 mm
MN: Individual wiring, Without lead wire
(With connector, socket)
MO: Individual wiring, Without
connector
With switch
Note 2) The electric connection to the
manifold will be positive
common specification when
light/surge voltage
suppressor is “Z” (Polar type).
2a/2b fitting port size
Straight fitting
(Metric size)
C2: ø2 one-touch fitting
C4: ø4 one-touch fitting
(Inch size)
N1: ø1/8" one-touch fitting
N3: ø5/32" one-touch fitting
Elbow fitting (Upward entry)
(Metric size)
L2: ø2 one-touch fitting
L4: ø4 one-touch fitting
(Inch size)
LN1: ø1/8" one-touch fitting
LN3: ø5/32" one-touch fitting
Elbow fitting (Downward entry)
(Metric size)
B2: ø2 one-touch fitting
B4: ø4 one-touch fitting
(Inch size)
BN1: ø1/8" one-touch fitting
BN3: ø5/32" one-touch fitting
With linkage
printed
circuit board
With linkage
printed
circuit board
With linkage
printed
circuit board
5
Series VV100
3 Port Solenoid Valve/D-sub Connector
Connector Type Manifold
Plug-in
Station 3
SOL.a
SOL.b
SOL.a
SOL.b
SOL.a
Station 4
Station 1
baCommon (+)
Individual wiring (M type)
Station 2
Single solenoid
Station 4
Double solenoid
Station 3
Double solenoid
Station 1
(D-sub connector)
Connector side
Solenoid
Common (+, –)
SOL.b
SOL.a
Station 3
SOL.a
Unused terminal
Station 2
SOL.a
SOL.b
Station 1
Double solenoid
Station 3
Common (+, –)
Single solenoid
(Double wiring specification)
Station 2
Double solenoid
Station 1
(D-sub connector)
Connector side
Solenoid
Connector side
Solenoid
Station 3
Station 2
Station 1
Double solenoid
Station 3
Double solenoid
Station 1
(D-sub connector)
SOL.b
SOL.a
SOL.a
SOL.b
SOL.a
Common (+, –)
Single solenoid
Station 2
Station 1
Station 5
Station 9
Station 4
Station 8
Station 12
SOL.a
SOL.b
SOL.a
SOL.b
SOL.b
SOL.a
SOL.a
SOL.b
SOL.a
SOL.b
Common
SOL.a
SOL.b
25
26
16
7
1
17
11
20
10
18
8
9
19
2
Station 7
SOL.b
SOL.a
Station 6
SOL.b
SOL.a
Station 2
Station 1
10
2
SOL.b
SOL.a
SOL.b
6
7
8
15
14
SOL.a
Common
9
1
Manifold Electrical Wiring (Image)
When a valve is added, the signals of the connector are assigned to the valve. This makes it completely unnecessary to disassemble the connector unit.
∗The connector arrangement shown below differs from the actual arrangement. Refer to the Connector Wiring Diagram below.
Individually Wired Valve
Single Solenoid with Double Wiring Specification
Single Solenoid and Double Solenoid
Type FA: D-sub connector (15 pins) Type FB: D-sub connector (26 pins)
Note) This circuit is for the specification with up to 7 stations of double solenoid
valves. This should be wired in order 1→9→2→10 without skipping or leav-
ing any connectors remaining.
Note) This circuit is for the specification with up to 12 stations of double solenoid
valves. This should be wired in order 1→2→3→4 with the exception of 9, 18
(Common) without skipping or leaving any connectors remaining.
Connector Wiring Diagram
When the non-polar type (U) valves are used, either +COM or –COM wiring of the manifold is possible. However, the valve does not switch with –COM if a
type (Z) is used. Be certain to use +COM.
Caution
6
Series VV100
AB
(8.9)
(9.4)
50.3
5.3
(When equipped with switch)
9.9
(For individual wiring)
22
9.8
2 x M2.6 x 0.45
No. 4-40 UNC
if the fitting size is inch 30.6
Approx. 300
(Lead wire length)
(Station 1)(Station n)
2a
2b
2a
2b
2a
2b
2a
2b
3
1
2a
2b
(Pitch)
P = 10.2
One-touch fitting
[1(P), 3(E) port]
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
4 x M3 x 0.5
Thread depth 4.8, hole depth 7 Note 3)
(For direct mounting)
11.8 18.7
40
11.45.7
12 14
4.531.1
L2 26.4
36.6
L1
(8.9)
If the fittings are
mounted on side.
4 x No. 10-32 UNF if the
mounting option “N” is selected
13
If the fittings are mounted on side.
(6.3)
Solenoid No. 13
ON
OFF
ON
OFF
Solenoid No.
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
Switch
(When equipped with switch)
24
U side D side
Dimensions
VV100-10F D1- U -
Stations 1
2
A
B
n: Stations
Ln
L: Dimensions
L1
L2
1
53.7
20.4
2
63.9
30.6
3
74.1
40.8
4
84.3
51
5
94.5
61.2
6
104.7
71.4
7
114.9
81.6
8
125.1
91.8
9
135.3
102
10
145.5
112.2
11
155.7
122.4
12
165.9
132.6
Note 1) 10FA and 10FB types have the same L1
and L2 dimensions, and the only difference
is the number of poles of the connector.
See page 6 for the pin arrangement.
Note 2) For manifold dimensions including elbow
fitting, see page 11.
Note 3) As the distance between the block end to
the thread is 2.5 mm, the screw depth
should be 5 to 7 mm.
7
Series VV100
3 Port Solenoid Valve/D-sub Connector
Connector Type Manifold
Plug-in
AB
4 x M3 for mounting
(Bracket)
(9.4)50.39.9
(For individual wiring)
5.3
(When equipped with switch)
6.7
56.9
L2
L3
8
(4.4)
3.2
3.322
9.75
15.5
11.5
(8.9)
6.7
13
Solenoid No.
(Station 1)(Station n)
For F2
30.6
Approx. 300
(Lead wire length)
(1.2)
ON
OFF
ON
OFF
24
Solenoid No.
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
Switch
(When equipped with switch)
2a
2b
2a
2b
2a
2b
2a
2b
2a
2b
3
1
(Pitch)
P = 10.2
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
Bracket for side ported 36.6
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
One-touch fitting
[1(P), 3(E) port]
40
11.8 18.7
1.2
1412
L1
(8.9)
If the fittings are
mounted on side.
11.45.7
2a
2b
2a
2b
2a
2b
2a
2b
2a
2b
3
1
4 x M3
for mounting
(Bracket)
Bracket for bottom ported
4
33 3.5
40
20 39
L4
L5
13
If the fittings are
mounted on side.
(6.3)
U side D side
2 x M2.6 x 0.45
No. 4-40 UNC
if the fitting size is inch
Dimensions
VV100-10F D1-
A
BF1
F2
U -
Stations 1
2
n: Stations
Ln
L: Dimensions
L1
L2
L3
L4
L5
1
53.7
42.2
50.2
61.2
68.6
2
63.9
52.4
60.4
71.4
78.8
3
74.1
62.6
70.6
81.6
89
4
84.3
72.8
80.8
91.8
99.2
5
94.5
83
91
102
109.4
6
104.7
93.2
101.2
112.2
119.6
7
114.9
103.4
111.4
122.4
129.8
8
125.1
113.6
121.6
132.6
140
9
135.3
123.8
131.8
142.8
150.2
10
145.5
134
142
153
160.4
11
155.7
144.2
152.2
163.2
170.6
12
165.9
154.4
162.4
173.4
180.8
Bracket option: F1 (For side ported)
Bracket option: F2 (For bottom ported)
Note 1) 10FA and 10FB types have the same L1 to
L5 dimensions, and the only difference is
the number of poles of the connector. See
page 6 for the pin arrangement.
Note 2) For manifold dimensions including elbow
fitting, see page 11.
8
Series VV100
AB
(8.9)
(9.4)
50.3
5.3
(When equipped with switch)
9.9
(For individual wiring)
ON
OFF
ON
OFF
24
Solenoid No. Switch
(When equipped with switch)
30.6
Approx. 300
(Lead wire length)
14.9
5.9
22
2a
2b
2a
2b
2a
2b
2a
2b
3
1
2a
2b
(Pitch)
P = 10.2
One-touch fitting
[1(P), 3(E) port]
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
4 x M3 x 0.5
Thread depth 4.8, hole depth 7 Note 3)
(For direct mounting)
11.8 18.7
40
6.9
17.1
11.45.7
12 14
4.531.1
L2
L1
(8.9)
If the fittings are
mounted on side.
13
If the fittings are
mounted on side.
(6.3)
13
Solenoid No.
(Station 1)(Station n)
U side D side
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
4 x No. 10-32 UNF if the
mounting option “N” is selected
2 x M2.6 x 0.45
No. 4-40 UNC
if the fitting size is inch
VV100-10F D2-
A
B
n: Stations
Ln
L: Dimensions
L1
L2
1
34.2
20.4
2
44.4
30.6
3
54.6
40.8
4
64.8
51
5
75
61.2
6
85.2
71.4
7
95.4
81.6
8
105.6
91.8
9
115.8
102
10
126
112.2
11
136.2
122.4
12
146.4
132.6
Note 1) 10FA and 10FB types have the same L1
and L2 dimensions, and the only difference
is the number of poles of the connector.
See page 6 for the pin arrangement.
Note 2) For manifold dimensions including elbow
fitting, see page 11.
Note 3) As the distance between the block end to
the thread is 2.5 mm, the screw depth
should be 5 to 7 mm.
U -
Stations 1
2
9
Series VV100
3 Port Solenoid Valve/D-sub Connector
Connector Type Manifold
Plug-in
AB
4 x M3 for mounting
(Bracket)
(8.9)
(9.4)
50.3
9.9
(For individual wiring)
5.3
(When equipped with switch)
6.7
6.7
56.9
L2
L3
4
8
4.4
3.2
3.3
Solenoid No. 13
(Station 1)(Station n)
ON
OFF
ON
OFF
Solenoid No. Switch
(When equipped with switch)
24
For F2
30.6
Approx. 300
(Lead wire length)
14.9
22 (1.2)
2a
2b
2a
2b
2a
2b
2a
2b
3
1
2a
2b
(Pitch)
P = 10.2
One-touch fitting
[1(P), 3(E) port]
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
Bracket for side ported
17.1
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
11.8 18.7
40
11.45.7
12 14
L1
1.2
(8.9)
If the fittings are
mounted on side.
2a
2b
2a
2b
2a
2b
2a
2b
3
1
2a
2b
4 x M3
for mounting
(Bracket)
Bracket for bottom ported
16 4
33 3.5
40
20
L3
L2
13
If the fittings are
mounted on side.
(6.3)
5.9
U side D side
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
2 x M2.6 x 0.45
No. 4-40 UNC
if the fitting size is inch
Dimensions
VV100-10F D2-
A
BF1
F2
U -
Stations 1
2
n: Stations
Ln
L: Dimensions
L1
L2
L3
1
34.2
42.2
50.2
2
44.4
52.4
60.4
3
54.6
62.6
70.6
4
64.8
72.8
80.8
5
75
83
91
6
85.2
93.2
101.2
7
95.4
103.4
111.4
8
105.6
113.6
121.6
9
115.8
123.8
131.8
10
126
134
142
11
136.2
144.2
152.2
12
146.4
154.4
162.4
Bracket option: F1 (For side ported)
Bracket option: F2 (For bottom ported)
Note 1) 10FA and 10FB types have the same L1 to
L3 dimensions, and the only difference is
the number of poles of the connector. See
page 6 for the pin arrangement.
Note 2) For manifold dimensions including elbow
fitting, see page 11.
10
Series VV100
1
3
2b 2b 2b 2b 2b
31
31
5.7
6.3
(27.6)
27.6
22.6
12.2
14.7
6.4
50.3
12.6
(9.4)
(2.4)
0.8
(7.8)
(4.2)
(6.3)
(47.8)
45.7
(35.8)
33.7
(51.6)
48.4
(39.8)
36.6
5.7
5.9
L1
6.9
17.1
(27.6)
40
4.5
27.6
22.6
12.2
14.7
11.4
6.4
31.1
(6.3)
L2
50.3
(If the fittings are
mounted on side.)
If the fittings are mounted on side.
[1(P) port]
One-touch fitting
Applicable tubing O.D: ø4
ø6
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
(2b port)
One-touch fitting
Applicable tubing O.D: ø4
ø6
[3(E) port]
One-touch fitting
If the fittings are
mounted on side.
Thread depth 4.8, hole depth 7 Note)
(For direct mounting)
4 x M3 x 0.5
(2a port)
One-touch fitting
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
(Pitch)
P = 10.2
2 x M2.6 x 0.45 Note)
∗Inch-size elbow fitting is not
available.
∗Inch-size elbow fitting is not
available.
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
4 x No. 10-32 UNF if the
mounting option “N” is selected
VV100-10FAD2-
Downward (Type B)
Solenoid No. 13
(Station 1)(Station n)
Solenoid No. 24
Note) As the distance between the block end to the
thread is 2.5 mm, the screw depth should be
5 to 7 mm.
Note) If the inch-size lock bracket screw (No. 4-40
UNC) is needed, the port size of air SUP/EXH
block should also be inch size (straight only).
U - 
Stations 1
2L
B
U side D side
U side D side
11
Series VV100
3 Port Solenoid Valve/D-sub Connector
Connector Type Manifold
Plug-in
• The valve arrangement is numbered as the 1st station from D side.
• Indicate the valves to be attached below the manifold part number, in order
starting from station 1 as shown in the drawing.
The asterisk denotes the symbol for assembly.
Prefix to the part no. of the solenoid valve, etc.
Ordering example (VV100-10-)
VV100-10-05U1-C6 1 set (Manifold part no.)
∗ V110N-D5MZ-C4 5 sets (Double solenoid part no.)
···············
··················
How to Order Manifold
SUP/EXH block
mounting position: U side
Valve stations
StationsSymbol
1 station
12 stations
01
12
SUP/EXH block port size
ø4 one-touch fitting (Straight)
ø6 one-touch fitting (Straight)
ø4 elbow fitting (Upward entry)
ø6 elbow fitting (Upward entry)
ø4 elbow fitting (Downward entry)
ø6 elbow fitting (Downward entry)
C4
C6
L4
L6
B4
B6
One-touch fitting (Metric size)
ø5/32" one-touch fitting (Straight)
ø1/4" one-touch fitting (Straight)
N3
N7
One-touch fitting (Inch size)
1
Standard (Same direction as the
cylinder ports)
2
Side
SUP/EXH block fitting entry direction
Mounting option
F1
With bracket (Standard)
F2
With bracket (Port downward)
Nil
Manifold direct mounting type
Manifold direct mounting type
N Note)
Note) If the mounting option “N” (Mounting nut: Inch size)
is selected, the bracket cannot be mounted.
Note) If the mounted valve is N.O., apply pres-
sure to the 3(E) port and exhaust air from
the 1(P) port.
U 1
VV100 10 C605
Series VV100
3 Port Solenoid Valve
Non Plug-in
Individual Wiring Manifold
1
32
V110N-D5MZ-C4 (5 sets)
Double solenoid (24 VDC)
How to Order Valve Manifold Assembly
Symbol
Mounting
With mounting nut
M3 x 0.5
With mounting nut
No. 10-32 UNF
(Inch size)
U side
Stations
D side
12
How to Order Valve Dedicated for Non Plug-in Individual Wiring
Rated voltage
24 VDC
12 VDC
5
6
With light/surge voltage suppressor
Light/surge voltage suppressor
Z
Note) Electric connection is positive common
specification.
Standard
With power saving circuit (Continuous duty type)
Coil specification
Nil
T
∗ Be certain to select “with power saving circuit” when the solenoid
valve will be energized continuously for long periods of time.
V1 1Z0 C45MNTD
Non plug-in
2a/2b fitting port size
Straight fitting
(Metric size)
C2: ø2 one-touch fitting
C4: ø4 one-touch fitting
(Inch size)
N1: ø1/8" one-touch fitting
N3: ø5/32" one-touch fitting
Elbow fitting (Upward entry)
(Metric size)
L2: ø2 one-touch fitting
L4: ø4 one-touch fitting
(Inch size)
LN1: ø1/8" one-touch fitting
LN3: ø5/32" one-touch fitting
Elbow fitting (Downward entry)
(Metric size)
B2: ø2 one-touch fitting
B4: ø4 one-touch fitting
(Inch size)
BN1: ø1/8" one-touch fitting
BN3: ø5/32" one-touch fitting
∗When ordering a connector assembly
separately, see back pages 6 and 7.
Connector entry
M: Individual wiring, With lead wire
Length 300 mm
MN:
Individual wiring, Without lead wire
(With connector, socket)
MO: Individual wiring, Without
connector
Without linkage
printed
circuit board
Without linkage
printed
circuit board
Without linkage
printed
circuit board
Normally closed (N.C.)
Normally open (N.O.)
Type of actuation
1
2
Specifications
Number of solenoids
Symbol
1 pc. (Single solenoid)
2 pcs. (Double solenoid)
S
D
∗ Normally closed and normally open
type cannot be mounted on the
same manifold.
13
Series VV100
3 Port Solenoid Valve
Individual Wiring Manifold
Non Plug-in
AB
AB
AB
AB
AB
(8.9)
(9.4)
50.39.9
30.6
Approx. 300
(Lead wire length)
2a
2b
2a
2b
2a
2b
2a
2b
2a
2b
3
1
(Pitch)
P = 10.2
One-touch fitting
[1(P), 3(E) port]
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
4 x M3 x 0.5
Thread depth 4.8, hole depth 7 Note 2)
(For direct mounting)
11.8 18.7
40
L2
11.45.7
L1
12 14
4.531.1
6.9
17.1
(8.9)
If the fittings are
mounted on side.
13
Solenoid No.
24
Solenoid No.
(Station 1)(Station n)
13
If the fittings are mounted on side.
(6.3)
U side D side
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
4 x No. 10-32 UNF if the
mounting option “N” is selected
Dimensions
VV100-10-
n: Stations
Ln
L: Dimensions
L1
L2
1
34.2
20.4
2
44.4
30.6
3
54.6
40.8
4
64.8
51
5
75
61.2
6
85.2
71.4
7
95.4
81.6
8
105.6
91.8
9
115.8
102
10
126
112.2
11
136.2
122.4
12
146.4
132.6
Note 1) For manifold dimensions including elbow
fitting, see page 11.
Note 2) As the distance between the block end to
the thread is 2.5 mm, the screw depth
should be 5 to 7 mm.
U -
Stations 1
2
14
Series VV100
13
Solenoid No.
(Station 1)(Station n)
2a
2b
2a
2b
2a
2b
2a
2b
2a
2b
3
1
(Pitch)
P = 10.2
One-touch fitting
[1(P), 3(E) port]
Applicable tubing O.D: ø2
ø4
ø1/8"
ø5/32"
Bracket for side ported
17.1
One-touch fitting
(2a, 2b port)
Applicable tubing O.D: ø4
ø6
ø5/32"
ø1/4"
11.8 18.7
40
11.45.7
L1
12 14 1.2
(8.9)
If the fittings are
mounted on side.
24
Solenoid No.
For F2
30.6
Approx. 300
(Lead wire length)
(1.2)
2a
2b
2a
2b
2a
2b
2a
2b
2a
2b
3
1
4 x M3
for mounting
(Bracket)
Bracket for bottom ported
16 4
33 3.5
40
20
L2
L3
AB
AB
AB
AB
AB
4 x M3 for mounting
(Bracket)
(8.9)
(9.4)50.39.9
6.7
6.7
56.9
L2
L3
3.3
4
4.4
3.2
8
13
If the fittings are
mounted on side.
(6.3)
U side D side
Light/surge voltage suppressor
SOL.a: Orange
SOL.b: Green
VV100-10-
n: Stations
Ln
L: Dimensions
L1
L2
L3
1
34.2
42.2
50.2
2
44.4
52.4
60.4
3
54.6
62.6
70.6
4
64.8
72.8
80.8
5
75
83
91
6
85.2
93.2
101.2
7
95.4
103.4
111.4
8
105.6
113.6
121.6
9
115.8
123.8
131.8
10
126
134
142
11
136.2
144.2
152.2
12
146.4
154.4
162.4
Bracket option: F1 (For side ported)
Bracket option: F2 (For bottom ported)
Note) For manifold dimensions including
elbow fitting, see page 11.
F1
F2
U -
Stations 1
2
15
Series VV100
3 Port Solenoid Valve
Individual Wiring Manifold
Non Plug-in
e
w
SUP/EXH block assembly fitting entry direction
Side
U side
D side
w
q
r
Mounting nut
Lock bracket Connector entry direction
Lateral
For non plug-in type
q
Connector entry direction
Upward
Manifold Exploded View
Note) If a bracket is intended to be mounted, select qConnector block assembly, wSUP/EXH end block assembly 1A or 3A, and eEnd block assembly 1A with mounting nut
(Metric size: M3).
q
w
e
r
DescriptionNo. Part no.
Connector block assembly Note)
(For plug-in)
End block assembly Note)
(For non plug-in)
Tension bolt (With hexagon nut)
SUP/EXH end block assembly Note)
(Common for plug-in and non
plug-in types)
<Fitting entry direction: Standard>
SUP/EXH end block assembly Note)
(Common for plug-in and non
plug-in types)
<Fitting entry direction: Side>
V100-192-A-15
V100-202-A
V100-193-1A-
[Mounting nut (Metric size: M3)]
V100-193-2A-
[Mounting nut (Inch size: No. 10-32 UNF)]
V100-193-3A-
[Mounting nut (Metric size: M3)]
V100-193-4A-
[Mounting nut (Inch size: No. 10-32 UNF)]
V100-199-1A
[Mounting nut (Metric size: M3)]
V100-199-2A
[Mounting nut (Inch size: No. 10-32 UNF)]
Note
Refer to Connector Block Assembly Part No. table
below.
: Stations (1 to 12) 2 pcs./set
(Metric size)
C4: ø4 one-touch fitting
C6: ø6 one-touch fitting
L4: ø4 elbow fitting (Upward entry)
L6: ø6 elbow fitting (Upward entry)
B4: ø4 elbow fitting (Downward entry)
B6: ø6 elbow fitting (Downward entry)
(Inch size)
N3: ø5/32" one-touch fitting
N7: ø1/4" one-touch fitting
<Mounting nut part no. (4 pcs./set)>
Metric size (M3): V100-197-1A
Inch size (No. 10-32 UNF): V100-197-2A
Connector Block Assembly Part No.
V100 192 A
Lock bracket thread type
Metric size (M2.6)
Inch size (No. 4-40 UNC)
Nil
U
D-sub connector type
15 pins
26 pins
15
26
Connector entry direction/Mounting nut thread type
Symbol
1
2
3
4
Thread type
Metric size (M3)
Inch size (No. 10-32 UNF)
Metric size (M3)
Inch size (No. 10-32 UNF)
Connector entry direction
Lateral
Upward
16
Series VV100
Manifold Options
Bracket Assembly
V100-198-1A (For side ported)
<Common for upward/
lateral connectors>
Bracket Mounting Procedure
<For side ported>
V100-198-3A (For bottom ported)
<For lateral connector>
V100-198-4A (For bottom ported)
<For upward connector>
∗The screws (M3) with which the bracket is
mounted on the manifold are included.
qFit the bracket to the groove at the
connector block (end block).
<For bottom ported>
Tighten the screws
(Tightening torque M3:
0.6 N·m).
wTighten the screws
(Tightening torque M3:
0.6 N·m).
Note) The bracket can be mounted on the block with the mounting nut (Metric size:
M3) only. It cannot be mounted on the block with inch-size mounting nut (No.
10-32 UNF).
17
Series VV100
3 Port Solenoid Valve
Individual Wiring Manifold
Non Plug-in
12
M3 x 0.5 recommended
L2
L1
30
33
M3 x 0.5 recommended
3
5
L1
L2
L1
L2
L1
L2
30
33
M3 thread through hole
27.5
31.1
M3 thread through hole
27.5
3.5
31.1
Manifold Options
Mounting Example
Manifold direct mounting
SUP/EXH block fitting entry direction: Standard Panel fitting dimensions/Mounting hole dimensions
Panel fitting dimensions/Mounting hole dimensions
Panel fitting dimensions/Mounting hole dimensions
Panel fitting dimensions/Mounting hole dimensions
Bracket mounting (For bottom ported)
Upward connector
Lateral connector
SUP/EXH block fitting entry direction: Side
Station n
123456789101112
20.4
22.2
30.6
32.4
40.8
42.6
51
52.8
61.2
63
71.4
73.2
81.6
83.4
91.8
93.6
102
103.8
112.2
114
122.4
124.2
132.6
134.4
L1
L2
Station n
123456789101112
20.4
10.2
30.6
20.4
40.8
30.6
51
40.8
61.2
51
71.4
61.2
81.6
71.4
91.8
81.6
102
91.8
112.2
102.0
122.4
112.2
132.6
122.4
L1
L2
Station n
123456789101112
61.2
36
71.4
46.2
81.6
56.4
91.8
66.6
102
76.8
112.2
87
122.4
97.2
132.6
107.4
142.8
117.6
153
127.8
163.2
138
173.4
148.2
L1
L2
Station n
123456789101112
52.4
36
62.6
46.2
72.8
56.4
83
66.6
93.2
76.8
103.4
87
113.6
97.2
123.8
107.4
134
117.6
144.2
127.8
154.4
138
164.6
148.2
L1
L2
18
Series VV100

Other manuals for VV100 Series

1

Other SMC Networks Control Unit manuals

SMC Networks 4501 Series User manual

SMC Networks

SMC Networks 4501 Series User manual

SMC Networks AKP Series User manual

SMC Networks

SMC Networks AKP Series User manual

SMC Networks EX600-SDN Series User manual

SMC Networks

SMC Networks EX600-SDN Series User manual

SMC Networks EX250-SAS7 User manual

SMC Networks

SMC Networks EX250-SAS7 User manual

SMC Networks XLH16 User manual

SMC Networks

SMC Networks XLH16 User manual

SMC Networks VHS20 Series User manual

SMC Networks

SMC Networks VHS20 Series User manual

SMC Networks VJ100 Manual

SMC Networks

SMC Networks VJ100 Manual

SMC Networks EX500 Series User manual

SMC Networks

SMC Networks EX500 Series User manual

SMC Networks VFR6000 Series User manual

SMC Networks

SMC Networks VFR6000 Series User manual

SMC Networks VHS20 Series User manual

SMC Networks

SMC Networks VHS20 Series User manual

SMC Networks VFS Series User manual

SMC Networks

SMC Networks VFS Series User manual

SMC Networks VTA301 Series User manual

SMC Networks

SMC Networks VTA301 Series User manual

SMC Networks S0700 Manual

SMC Networks

SMC Networks S0700 Manual

SMC Networks VP 46 Series User manual

SMC Networks

SMC Networks VP 46 Series User manual

SMC Networks VM100-A Series User manual

SMC Networks

SMC Networks VM100-A Series User manual

SMC Networks ASR Series User manual

SMC Networks

SMC Networks ASR Series User manual

SMC Networks EX260 Series User manual

SMC Networks

SMC Networks EX260 Series User manual

SMC Networks EX260 Series User manual

SMC Networks

SMC Networks EX260 Series User manual

SMC Networks IBV1 Series User manual

SMC Networks

SMC Networks IBV1 Series User manual

SMC Networks 56-VQC1000 Series Manual

SMC Networks

SMC Networks 56-VQC1000 Series Manual

SMC Networks SJ4000 Series User manual

SMC Networks

SMC Networks SJ4000 Series User manual

SMC Networks KE Series User manual

SMC Networks

SMC Networks KE Series User manual

SMC Networks SJ3000A User manual

SMC Networks

SMC Networks SJ3000A User manual

SMC Networks CP96 Series User manual

SMC Networks

SMC Networks CP96 Series User manual

Popular Control Unit manuals by other brands

PIKO 46192 manual

PIKO

PIKO 46192 manual

Siemens SINUMERIK 840D sl manual

Siemens

Siemens SINUMERIK 840D sl manual

Sagem MO300 M2M Application note

Sagem

Sagem MO300 M2M Application note

Bray 63 Series Installation, operation and maintenance manual

Bray

Bray 63 Series Installation, operation and maintenance manual

Siemens SINUMERIK 808D operating instructions

Siemens

Siemens SINUMERIK 808D operating instructions

Monacor ATT-1950 instructions

Monacor

Monacor ATT-1950 instructions

Actis CIO-32 user guide

Actis

Actis CIO-32 user guide

Viessmann VITOTRONIC 100 Operating Instructions for the System User

Viessmann

Viessmann VITOTRONIC 100 Operating Instructions for the System User

SEW-Eurodrive MAXOLUTION MAXO-MS Assembly and operating instructions

SEW-Eurodrive

SEW-Eurodrive MAXOLUTION MAXO-MS Assembly and operating instructions

Burkert 3320 quick start guide

Burkert

Burkert 3320 quick start guide

Sierra Wireless AirPrime AR7584 Hardware integration guide

Sierra Wireless

Sierra Wireless AirPrime AR7584 Hardware integration guide

Pentair F783E operating manual

Pentair

Pentair F783E operating manual

Aventics CONTROLAIR H-4 Service information

Aventics

Aventics CONTROLAIR H-4 Service information

Water Specialist WS1TT Drawings and Service Manual

Water Specialist

Water Specialist WS1TT Drawings and Service Manual

Solartron Metrology BICM Series User Leaflet

Solartron Metrology

Solartron Metrology BICM Series User Leaflet

DELTA DORE TYXIA 253 Installation and use

DELTA DORE

DELTA DORE TYXIA 253 Installation and use

LS ELECTRIC XGT Series user manual

LS ELECTRIC

LS ELECTRIC XGT Series user manual

Setra Systems Flex Installation and operation manual

Setra Systems

Setra Systems Flex Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.