logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Smeg
  6. •
  7. Ventilation Hood
  8. •
  9. Smeg K181X70 Installation guide

Smeg K181X70 Installation guide

Other Smeg Ventilation Hood manuals

Smeg KSET66D Guide

Smeg

Smeg KSET66D Guide

Smeg K28 User manual

Smeg

Smeg K28 User manual

Smeg KD61X2 User manual

Smeg

Smeg KD61X2 User manual

Smeg KSEG5X User manual

Smeg

Smeg KSEG5X User manual

Smeg KT61XE User manual

Smeg

Smeg KT61XE User manual

Smeg SBQ36X User manual

Smeg

Smeg SBQ36X User manual

Smeg KSEG5-1 User manual

Smeg

Smeg KSEG5-1 User manual

Smeg SHW800B User manual

Smeg

Smeg SHW800B User manual

Smeg KSEG52 Technical manual

Smeg

Smeg KSEG52 Technical manual

Smeg KSE110AP9 User manual

Smeg

Smeg KSE110AP9 User manual

Smeg KSEI62 User manual

Smeg

Smeg KSEI62 User manual

Smeg KSED97X Technical manual

Smeg

Smeg KSED97X Technical manual

Smeg SHW410X User manual

Smeg

Smeg SHW410X User manual

Smeg HOTTE KCV60SE2 User manual

Smeg

Smeg HOTTE KCV60SE2 User manual

Smeg KI120X User manual

Smeg

Smeg KI120X User manual

Smeg KSEG5XSA Technical manual

Smeg

Smeg KSEG5XSA Technical manual

Smeg Hood SED908EB User manual

Smeg

Smeg Hood SED908EB User manual

Smeg KSEI62E User manual

Smeg

Smeg KSEI62E User manual

Smeg KCM900POE User manual

Smeg

Smeg KCM900POE User manual

Smeg KSE 61X User manual

Smeg

Smeg KSE 61X User manual

Smeg KQ45XE User manual

Smeg

Smeg KQ45XE User manual

Smeg kset 650 Guide

Smeg

Smeg kset 650 Guide

Smeg KSEC61X User manual

Smeg

Smeg KSEC61X User manual

Smeg KSEV97X User manual

Smeg

Smeg KSEV97X User manual

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Zephyr Spruce AK9834BS Use, care and installation guide

Zephyr

Zephyr Spruce AK9834BS Use, care and installation guide

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Nibe S Series Installer manual

Nibe

Nibe S Series Installer manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

K181X70 smeg wallmount rangehood, 70cm
ID120310
Code K181X70
dimensions 700mm W x 496mm D x 1190mm H
maximum
finish satin stainless steel
installation wall mount
motor 190 watt centrifugal, twin impellors,
double-sided air uptake
capacity 5903m/hr net
noise rating 29–50 dBA
extraction direct duct ot recirculate
illumination two x 20 watt halogen globes,
separate ON/OFF buttons
speeds three separate buttons
filtration 2 x stainless steel/aluminium 4-ply
grease filters, removable, warm
hand wash
warranty two years parts and labour
PERFORMANCE
Highly-efcient air extraction of up to 590 cubic metres an hour true (net)
ensures the very swift removal of cooking vapours, odours and heat.
The higher speed selections are perfect for the more vigorous styles of
cooking such as stir frying, griddle cooking and boiling, the lower speeds
at the touch of a button are perfect for simmers.
QUIETNESS
29 to 50 dBA. The motor/impellor encasements are smooth-walled to
minimise air drag and, hence, noise. All metal joins are welded to reduce
vibration.
SAFETY
Thermal overload protection on motor, re retardant hardened metal
and mesh, VO self-extinguishing plastic for motor housing and internal
ue.
MAINTENANCE
No tools required — easy lift-out pair of grease lters for washing. For light
replacement, simply rotate the decorative ange for access to halogen
globes.
DUCTING
Direct ducting to atmosphere ensures the maximum removal of grease/
oil/particle-laden vapour plus the odours and, very importantly, the heat,
resulting in a cleaner, cooler, more comfortable work area.
RECIRCULATION
When the cooking vapours cannot be ducted to atmosphere, the
ltered air can simply be redirected back into the kitchen via a duct pipe
through the overhead cabinetry.
CHARCOAL FILTERS
This is a purchasable accessory. It is inserted just below the centrifugal
motor and is designed to absorb and diminish cooking odours. Periodic
inspection is recommended before replacement. The activated
charcoal lter is optionally used for recirculation only. Charcoal lters are
not to be washed. The are replaceable.
DUCTING MATERIAL
Smooth internal walled duct pipe lengths ensure the most efcient air
movement and quieter operation. Consider either high temperature
rated PVC or galvanised sheet metal piping. The exible ducting cab be
ideal for a very short, tight run.
The rangehood’s air exit aperture is designed for 150mm (6”) ducting;
however, a 125mm diameter (5”) adaptor can be purchased for optional
use.
DELAY STOP
Ideally, a rangehood should run for several minutes after all cooking
is ceased in order to drag through residual vapours and odours. By
selecting the delay stop button at the end of the cooking, the rangehood
will turn the motor off in ve minutes as well as the lights if they were left
on.
CLEANING PROMPT
After 30 hours use the LED window will prompt visually to inspect the
grease lters for possible cleaning. Simply use the Reset button to clear
the LED window.
K181X70 smeg wallmount rangehood, 70cm
ID120310
Code K181X70
WARNING: technical specifications and product sizes can be varied by the manufacturer,
without notice. Cutouts for appliances should only be by physical product measurements.
The above information is indicative only.
NB: drawings are not to scale — they are to assist only
electricity supply 240 volt, 50 Hz
electrical
connection
1.5 metre connected power cord for
plugging to standard 10 amp GPO
wattage 190 watt motor, 2 x 20 watt halogen globes,
230 watts total
current 0.96 amps
packaged
dimensions
810mm x 470mm x 630mm = 0.24m³
gross weight 20.45kg
net weight 17.50 kg
supplied
NB:
• instructions for installation, operation,
maintenance
• one-way buttery valve for optional
tment to air exit aperture
• xing screws
• 150mm/125mm diameter ducting adaptor
• recirculation diverter kit
— direct ducting to atmosphere requires
150mm diameter ducting
— recirculation to kitchen requires 125mm
diameter ducting
option activated charcoal lter for optional tment
in recirculation installation, part number
08999802
SPEED 1 23
net air capacity m3/hr 205 310 590
pressure mm H20 12 25 39
input wattage 45 85 190
noise dBA 29 34 50
direct ducting to atmosphere
recirculation to kitchen
chimney plan detail
PLEASE NOTE the difference in maximum heights between the ‘direct duct to
atmosphere’ installation and the ‘recirculation’ installation. The recirculation
installation’s maximum height is 1190mm due to the active recirculation vents necessarily
being exposed on each side of the chimney. The ‘direct duct to atmosphere’ installation
shows the now redundant recirculation vents being concealed by the lower chimney by
reversing — that is, turning the upper chimney piece 180 degrees on the vertical.
If a higher chimney height is required for the ‘direct duct to atmosphere’ installation, that
is, up to 1190mm, simply follow the ‘recirculation’ installation and have the recirculation
vents exposed, though redundant.
253
278
97
150
min 470
min 650
278
253
700
496
60 510
min 680 — max 1000
min 110
max 430
700
496
510
min 770 — max 1190
min 200
max 620
253
278