Pressure Gauge Replacement
Model 464 250 psi
High Quality Groundwater and Surface Water Monitoring Instrumentation
(Page 1 of 2)
Tools and Materials Needed
1. 464 Panel Mount Gauge 250 psi (Spare) (#111823)
2. 3/32" Allen Key
3. 5/16" Wrench
4. 16 mm Wrench
5. Teflon®Tape
Instructions
1. Turn the Control Unit off and remove the batteries.
2. Use the 3/32" Allen key to undo the four hex screws on the sides
of the Control Unit.
Hex
Screws
Hex
Screws
5. Use the 16 mm wrench to remove the elbow fitting from the
Pressure Gauge.
Panel
Pressure Gauge
3. Remove the panel from the Control Unit and flip it over to access
the Pressure Gauge.
®Solinst is a registered trademark of Solinst Canada Ltd.
Pressure Gauge
464 Panel Mount Gauge 1/8" NPTM (Spare) (#111823)
4. Push down on the “grasping ring” on the elbow fitting and pull to
remove the black tubing from the elbow on the Pressure Gauge. Do
the same for the clear tubing connected to the Solenoid (next to the
Pressure Gauge). Remove other tubing, if required, to gain more
access. Remember where the tubing connects.
“Grasping Rings”
Teflon is a registered trademark of DuPont.
6. Use the 5/16" wrench to remove the two nuts holding the metal
bracket in place.
7. Remove the metal bracket and push the Pressure Gauge out
through the front of the panel. Pushing the Pressure Gauge out
may take some force.
Printed in Canada
December 1, 2014
(#111824)
(Page 2 of 2)
For further information contact: Solinst Canada Ltd.
Fax: +1 (905) 873-1992; (800) 516-9081 Tel: +1 (905) 873-2255; (800) 661-2023
35 Todd Road, Georgetown, Ontario Canada L7G 4R8
Web Site: www.solinst.com E-mail: [email protected]
8. Remove the bracket from the new Pressure Gauge. Wrap Teflon
tape around the threads on the new Pressure Gauge.
9. Push the new Pressure Gauge into place through the front of the
panel. Ensure the new Pressure Gauge is oriented correctly.
Note: There will be a label on the side of the new Pressure Gauge.
Tilt the side with the label into the opening in the panel first,
to help get the Pressure Gauge in place. You may remove
the label if you are still having difficulty getting the Pressure
Gauge through the opening.
10. Install the new metal bracket and the washers to hold the Pressure
Gauge in place. Ensure the washers are just snug.
11. Install the elbow fitting onto the new Pressure Gauge. Use a second
wrench to hold Gauge while tightening the elbow fitting. Ensure the
fitting is all the way on. Position the elbow fitting so that a flat side
lines up with the screw. This allows access to reconnect the clear
tubing.
12. Push in to reconnect the black tubing to the elbow fitting, and the
clear tubing to the fitting on the Solenoid (reconnect any other
tubing).
13. Place the panel in the Control Unit case and re-install the four hex
screws.
14. Re-install the batteries. Test the Control Unit using compressed
air to ensure proper connections were made when replacing the
Pressure Gauge.
Flat Side

Other Solinst Control Unit manuals

Solinst 464 Mk3 User manual

Solinst

Solinst 464 Mk3 User manual

Solinst 464 Operating instructions

Solinst

Solinst 464 Operating instructions

Solinst 464 250 psi Use and care manual

Solinst

Solinst 464 250 psi Use and care manual

Solinst 464 125 psi Use and care manual

Solinst

Solinst 464 125 psi Use and care manual

Solinst 464 125 psi Use and care manual

Solinst

Solinst 464 125 psi Use and care manual

Solinst 464 User manual

Solinst

Solinst 464 User manual

Solinst 464 Mk3 250 psi Use and care manual

Solinst

Solinst 464 Mk3 250 psi Use and care manual

Solinst 464 125 psi Configuration guide

Solinst

Solinst 464 125 psi Configuration guide

Solinst 464 250 psi Configuration guide

Solinst

Solinst 464 250 psi Configuration guide

Solinst 464 Mk3 250 psi Use and care manual

Solinst

Solinst 464 Mk3 250 psi Use and care manual

Popular Control Unit manuals by other brands

Zumtobel SensControl II operating manual

Zumtobel

Zumtobel SensControl II operating manual

edisio EMV-400M manual

edisio

edisio EMV-400M manual

Advanced Solar Photonics ASP-390M Safety & instruction manual

Advanced Solar Photonics

Advanced Solar Photonics ASP-390M Safety & instruction manual

MITS 88-RMB2 user manual

MITS

MITS 88-RMB2 user manual

Festo CPX-FVDA-P Description

Festo

Festo CPX-FVDA-P Description

V2 City7 instruction manual

V2

V2 City7 instruction manual

DEMA 481-2 installation instructions

DEMA

DEMA 481-2 installation instructions

powersoft LiteMod 4HC user guide

powersoft

powersoft LiteMod 4HC user guide

Spirax Sarco PV4 Installation and maintenance instructions

Spirax Sarco

Spirax Sarco PV4 Installation and maintenance instructions

FMA Direct Cellpro 4s quick start guide

FMA Direct

FMA Direct Cellpro 4s quick start guide

GE IC3645SR4W606N6 Installation and operation

GE

GE IC3645SR4W606N6 Installation and operation

api technologies corp. SmartStep 150T Installation & operating instructions

api technologies corp.

api technologies corp. SmartStep 150T Installation & operating instructions

Danfoss PVG 32 installation guide

Danfoss

Danfoss PVG 32 installation guide

Videx 4212 Series Guide

Videx

Videx 4212 Series Guide

Mitsubishi Q Series user manual

Mitsubishi

Mitsubishi Q Series user manual

Lenze L-force 9400 manual

Lenze

Lenze L-force 9400 manual

Teac RC-L800 owner's manual

Teac

Teac RC-L800 owner's manual

Festo CPX-2AE Series Brief description

Festo

Festo CPX-2AE Series Brief description

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.