Application
The secondary signal controller
can only be used in wire saving
systems with HTS/HTC/HTSV/
HTCV 811-.... The controller makes
available a switching contact for
door and storey calls. There are two
floating work contacts with a
common terminal available for this.
The NSC 602-... can be mounted/
inserted in a size 55 mm switch box
underneath the telephone or in an
offset location in a branching box.
The secondary signal controller be-
haves in the same way as a house
telephone connected in parallel, i.e.
it is not possible to connect another
house telephone in parallel.
1Connection of the NSC 602-... for
door and storey calls.
Installation and commissioning
Installation and commissioning
procedures are described in the
system manual 1+n technology
(enclosed with line rectifier
NG 602-... ).
Technical data
•Switching contacts for:
Door call = S1/S2
Storey call = S1/S3
•Max. contact load 24 V/1A
•Admissible ambient temperature
0°–40° C
•Protective system IP 20
•Dimensions Ø51 x 23 mm
Application
L’interface sonnerie auxiliaire
peut seulement être utilisé dans le
système économique en fils avec les
combinés HTS/HTC/HTSV/
HTCV 811-... Le contrôleur met à
disposition un contact de
commutation pour l'appel de porte
et d'étage. Pour cela l’in-terface met
adisposition 2 contacts secs avec un
commun. Le NSC 602-.. peut être
logé dans une boîte de dé-rivation
de diam. 55 mm derrière le combiné
ou dans une boîte de dé-rivation
déportée.
L’interface se comporte comme un
combiné branché en parallèle.
Il n’est plus possible de brancher un
autre combiné en parallèle.
1Raccordement du NSC 602-... pour
l'appel de porte et d'étage.
Installation et mise en service
L'installation et la mise en service
sont décrits dans le manuel système
Technique 1+n (joint au bloc
d'alimentation NG 602-...).
Caractéristiques techniques
•Contacts pour:
Appel portier = S1/ S2
Appel d’étage = S1/ S3
•Puissance max. des contacts:
24 V/ 1A
•Plage de température 0°–40° C
•Indice de protection IP 20
•Dimensions Ø51 x 23 mm
English
Installation
Français
Installation
Impiego
Il controller a segnale derivato
può essere utilizzato solo nei sistemi
arisparmio di fili con HTS/HTC/HTSV/
HTCV 811-... Il controller mette a
disposizione un contatto di
commutazione per la chiamata dal
posto esterno e dal piano. A tale
scopo si hanno a disposizione 2
contatti autooperanti a potenziale
zero con un morsetto comune.
L’NSC 602-...può essere montato o
incorporato in una scatola dell’inter-
ruttore di 55 sotto il telefono o col-
locato in una scatola di derivazione.
Il controller a segnale derivato ha le
stesse peculiarità di un telefono di
citofono collegato in parallelo, ciò
significa che non può essere colle-
gato in parallelo nessun ulteriore
telefono.
1Collegamento dell’NSC 602-... per
la chiamata dal posto esterno e dal
piano.
Installazione e messa in funzione
L’installazione e la messa in funzione
sono descritte nel manuale del
sistema 1+n (allegato all’alimenta-
tore NG 602-...).
Dati tecnici
•Contatti di commutazione per:
Chiamata di porta = S1/S2
Chiamata di piano = S1/S3
•Carico dei contatti max. 24 V/1 A
•Temperatura ambiente ammessa
0°–40° C
•Classe di protezione IP 20
•Dimensioni Ø51 x 23 mm
Italiano
Installazione