5
secs
30
mins
60
mins
LED AC Indicate that the unit is receiving power.
LED Charge/Full Gives information on battery charging.
LED Battery Indicate battery voltage range
LED Fail Indicate error status.
LED 5 sec Indicate the unit is performing a 5 second test.
LED 30 mins Indicate the unit is performing a 30-minute test.
LED 60 mins Indicate the unit is performing a 60-minute test.
Switch ON/OFF Press to turn ON/OFF the lamp. (while the unit is not plugged in)
Switch Test For testing the device’s availability. (during normal circumstance)
IR Receiver Infrared signal sensor used to receive signal from
the infrared remote.
Dimmer Press to adjust the brightness level
(only supported in the HZ models).
1. Controlled by a highly intelligent 8-bit micro controller.
2. Automatically self-test every 30 days and 90 days to help extend the life of the
battery.
3. Testing can be activated remotely using the infrared remote.
4. A quick test function on the unit that can carry out a self-test in 5 seconds.
5. The time and date of the automatic test can be set from both the remote and the
unit itself.
6. Using high quality LEDs with a lifetime of over 50,000 hours, providing bright and
constant illimitation throughout its operation.
7. The unit’s outer case is made from ABS UL94 V-O Flame Retardant plastic that is
highly resistant to impact and corrosion.
USER MANUAL
Self-Contained Emergency Light CU-NC Series
Remote Testing
Status Indicators and Testing Buttons
Features
1. The unit should be installed indoors away from direct sunlight and rain or moisture.
2. The unit should be stored in temperatures under 25 Degree Celsius and the battery
should be charged every 3 months to maintain its operational life.
1. The unit can be installed on leveled ground or hung up.
2. Install properly and securely to prevent accidents that could cause damage to the
unit or other people and property.
3. Plug the unit into a power socket with a 220Vac power supply. The emergency lamp
will remain on for about 5 seconds before turning o.
4. The AC LED light will show if the unit is receiving power from the power socket.
The Charge/Full LED will blink if the battery is charging and will remain on when the
battery if fully charged
5. When the unit is operational, tests can be performed using the Test button on the
unit or remotely using the remote with the following options.
-Press the 5sec button to perform a 5 second test, after which the unit will return to
normal operation.
-Press the 30min button to activate the automatic self-test. The unit will self-test
every 30 days for a duration 30 minutes.
-Press the 60min button to activate the automatic self-test. The unit will self-test
every 90 days for a duration 60 minutes.
-To cancel the test, press the OFF button.
Note : When activating the self-test function whether through the remote or the
button on the unit the test button will have the same function.
Installation and Operation
Important Note on Using the Unit
FRONT VIEW
BACK VIEW
SIDE VIEW
W 80
H 230
L 250
H 230
197
L 250
H 230
5
secs
30
mins
60
mins
Remote Testing
How to use the remote
Problem Cause What to do
- Power not getting to the unit
after plugging in.
The LED AC light does not
turn on.
- The power socket might not have
any power.
- The plug or socket is loose.
- The AC.220V fuse is blown.
- Check the 220VAC power supply.
- Check the plug and socket.
- Contact customer service.
- Emergency light does not
turn on after the power went
out.
- The unit is not plugged in.
- The lamp is faulty.
- The circuit’s wiring is loose.
- The DC fuse is blown.
- Check that the unit is plugged in.
- Contact customer service.
- Contact customer service.
- Contact customer service.
- Emergency light only turns
on for a short time after the
power went out.
- The battery is not fully charged.
- The battery has degraded.
- Fully charge the battery.
- Contact customer service to
replace the battery
Initial Trouble Shooting
Dimension (mm)
5
secs
30
mins
60
mins
Perform a 5 second test.
Perform a 30-minute test.
Perform a 60-minute test.
Increase the lamp’s brightness
(only available with the HZ lamp type)
Decrease the lamp’s brightness
(only available with the HZ lamp type)
Turn on/o the emergency lamp or cancel
any test in progress.
For any further questions about your product
please feel free to contact SUNNY’s customer
service department.
Tel. (+66) 02-948-4450-2
E-mail: [email protected]
1. The product will only be under warranty if the customer fills in the “warranty card”
and return the “return part” to the company within 7 days of purchasing the product.
If this is not done within the specified time then the warranty will be considered void.
2. The warranty only covers the unit’s internal parts for the duration specified by the
company counting from the date of purchase.
3. Please show the warranty card every time when contacting our service department
or the dealer you purchased the unit from.
4. The warranty will be considered void in the following cases.
The unit has been used outside of its intended use specified in the manual.
The unit has been used with equipment that does not meet the specifications
specified within the manual.
The unit has been damaged from impact, for example parts are dented, scratched
missing or distorted.
The unit has been modified or repaired by people not ocially certified by our
company.
The Sticker Warranty Void has been removed or torn.
The unit is damaged from negligence or incompetent use, for example, the
battery is swollen, the batter has been overcharged, the battery has been
damaged from quick charging, the battery has been short-circuited, the battery’s
charged has been completely drained.
The unit has been stored improperly, for example, it was exposed to moisture
causing rust and damage to the internal circuitry.
Damaged was caused by a malfunction in the AC power supply.
Damage from natural disaster such as fire, moisture, submersion in liquids,
chemical damage or from unavoidable circumstances.
Damage from animals or insects.
Note : Please read the manual carefully before installation and operation to understand
how to properly operate the unit.
Terms for Warranty and Service
IsOn Import-Export Co., Ltd.
2915-2917 Ladprao Road, Klongjan,
Bangkapi, Bangkok 10240

This manual suits for next models

1

Other Sunny Lighting Equipment manuals

Sunny SG Series User manual

Sunny

Sunny SG Series User manual

Sunny MESG Series User manual

Sunny

Sunny MESG Series User manual

Sunny CU-IP66 Series User manual

Sunny

Sunny CU-IP66 Series User manual

Sunny MCU Series User manual

Sunny

Sunny MCU Series User manual

Sunny MEL Series User manual

Sunny

Sunny MEL Series User manual

Sunny TM Series User manual

Sunny

Sunny TM Series User manual

Sunny Emergency Exit Series User manual

Sunny

Sunny Emergency Exit Series User manual

Sunny SG-IP66 Series User manual

Sunny

Sunny SG-IP66 Series User manual

Sunny SGM Series User manual

Sunny

Sunny SGM Series User manual

Sunny TM Series User manual

Sunny

Sunny TM Series User manual

Sunny SG Series User manual

Sunny

Sunny SG Series User manual

Sunny SG-R Series User manual

Sunny

Sunny SG-R Series User manual

Sunny 6 Series User manual

Sunny

Sunny 6 Series User manual

Sunny SNP Series User manual

Sunny

Sunny SNP Series User manual

Popular Lighting Equipment manuals by other brands

Ledj Pixel Storm 6 Tri Batten user manual

Ledj

Ledj Pixel Storm 6 Tri Batten user manual

Emos ZM5171 manual

Emos

Emos ZM5171 manual

JB Systems LASER BURST III Operation manual

JB Systems

JB Systems LASER BURST III Operation manual

Cooper Lighting HALO ALL-PRO AL3050LPC Series instruction manual

Cooper Lighting

Cooper Lighting HALO ALL-PRO AL3050LPC Series instruction manual

Acuity Brands Lighting AFFINITY AFF OELR manual

Acuity Brands Lighting

Acuity Brands Lighting AFFINITY AFF OELR manual

Griven Jasper MK2 user manual

Griven

Griven Jasper MK2 user manual

Dialighting LED Par IP65 RGB user manual

Dialighting

Dialighting LED Par IP65 RGB user manual

Govee H6601 user manual

Govee

Govee H6601 user manual

Lightolier AGU specification

Lightolier

Lightolier AGU specification

PLG LILIUM 6 user manual

PLG

PLG LILIUM 6 user manual

IKEA STORJORM installation instructions

IKEA

IKEA STORJORM installation instructions

Saxby Lighting Picco instruction manual

Saxby Lighting

Saxby Lighting Picco instruction manual

BiiWheel NaturalShine Half Egg 500 NG Mini instruction manual

BiiWheel

BiiWheel NaturalShine Half Egg 500 NG Mini instruction manual

ProtoMachines LED 1 manual

ProtoMachines

ProtoMachines LED 1 manual

Xtreme Power 75159 Owner's manual and safety instructions

Xtreme Power

Xtreme Power 75159 Owner's manual and safety instructions

Artecta Par 30 Tracklight - Warm on Dim V1 user manual

Artecta

Artecta Par 30 Tracklight - Warm on Dim V1 user manual

KRIOS 14008 instruction sheet

KRIOS

KRIOS 14008 instruction sheet

Ecco Stick-A-LED Installation and operation instructions

Ecco

Ecco Stick-A-LED Installation and operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.