T&D TR-7wf Series Instruction sheet

Please Read First TR-71wf
TR-72wf
TR-72wf-H
Part Names and Functions
[RIGHT SIDE][FRONT]
[BACK]
[LEFT SIDE]
Sensor Jack
Channel 1
For connecting a sensor INTERVAL Button Press to change recording/upload
interval settings or view current
settings.
Sensor Jack
Channel 2
For connecting a sensor
(TR-71wf only)
REC/STOP Button Press to start or stop recording.
POWER Button Use this to turn the device
ON and OFF.
USB Port For connecting to PC with USB
cable
DISPLAY Button Press to change LCD
display mode.
Battery Cover
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for
protecting yourself and other people from bodily harm and/or damage to property.
Explanation of Symbols
<Warning Symbols>
DANGER
These entries are actions that absolutely under no circumstance
should be taken. The taking of such an action may cause serious
personal physical damage or death.
CAUTION These entries are actions that if taken may lead to physical injury or
damage to persons or things.
<Picture Symbols>
Denotes an impor-
tant warning or
caution.
Denotes a forbidden
action.
Denotes an action
that should be
carried out.
DANGER To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and accessories.
Do not use the unit in any environment that is exposed to chemicals and harmful
gases. Doing so may cause corrosion and/or other danger to the unit. Also, coming
in contact with hazardous substances may cause bodily harm to the user or people
nearby.
This unit is not water resistant. If water or a foreign object enters the case, immedi-
ately remove batteries and stop using it.
Do not handle the unit, remove batteries or cables with wet hands.
This product has been designed for private and/or industrial use only. It should not
be used in situations where strict safety precautions are necessary such as with
medical equipment, or in systems directly or indirectly connected with human life or
well-being.
Do not drop or expose the unit to a strong impact.
Do not connect any communication cables connected to the unit to telephone line
outlets. Continued use may cause re or electrocution.
Do not cut or process the cords for the communication cables. Also, do not twist,
pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static electricity from
your body by touching metal around you (such as a door knob and window frame)
before touching the unit.
Place and store the unit and accessories out of the reach of children.
We are not responsible for any damage, malfunction or trouble, whether direct or
indirect, caused by the use of our product.
Do not use any battery, sensor, or cable other than those specied by T&D Corpora-
tion.
Do not put anything on top of the cable. This may cause overheating.
Do not disconnect the USB cable during USB communication. Doing so may cause
adverse effects to the unit and/or PC.
Make sure that sensor and cable plugs are all inserted fully, so as not to cause an
improper connection. Also, when unplugging the cable from the unit, do not pull the
cord, but hold the connector to disconnect.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noise,
immediately remove the batteries and stop using it. Also, unplug the unit from the
PC.
If the unit is not to be used for a long period of time, remove batteries. If left in the
unit, the batteries may leak and lead to malfunctioning. Install new batteries when
starting or re-starting to use a unit.
CAUTION Do not place or store in the following areas:
• Areas exposed to direct sunlight
• Areas exposed to excessive heat or high
temperatures such as near re or heating
equipment
• Areas exposed to static electricity
• Areas exposed to strong magnetic elds
• Areas exposed to dampness
• Areas subject to condensation or wet areas
• Areas exposed to excessive vibration
• Areas exposed to excessive smoke, dust or dirt.
CAUTION Other Precautions
• Use the unit in the specied operating environment. Do not use it for any purpose other than for
which it was designed.
• Condensation may occur inside the case when a unit is moved from one environment to another
where there is a great difference in temperature.
• Do not use the unit in wet areas or places exposed to water such as bathroom.
• When connecting the unit to your PC, make sure to follow all warnings and directions from your com-
puter manufacturer.
• We shall not guarantee the unit's operation if it has been connected to a PC using a USB hub or a
USB extension cable.
• Do not insert any foreign objects into any of the units' jacks.
• If the unit gets dirty, wipe it with a clean cloth.
• Make sure to remove dust and dirt from plugs of any cables.
• Battery terminals may provide insufcient contact due to age or vibration. This may lead to data loss.
• If the unit is not to be used for a long period of time, for safety reasons please remove the battery. If
left in the unit, the battery may leak and lead to malfunctioning.
• Please note that this document has been written based on the presupposition that details about con-
tracts with an Internet provider, specic network environments and the set-up of any other necessary
equipment to enable network connection has already been taken care of by the User and that con-
nection has been conrmed as workable. T&D Corporation shall not be responsible for any damages
which a contractor, a user or a third party may suffer, whether direct or indirect, due to the inability to
communicate or use communication devices.
CAUTION Notices about Sensors
• Do not connect any sensor to the unit other than those specied by T&D Corporation.
• Make sure to use sensors within the measurement range indicated in the specications for that
sensor.
• If extremely severe temperature changes occur, it may result in large errors in humidity measure-
ment. Once the sensor's temperature becomes stable, the measurements will return to normal.
• Do not connect the sensor to any data logger other than those specied by T&D Corporation.
• Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy
and cause damage or malfunction.
• When the sensor is not to be used for a long period of time, please store it at normal tempera-
ture and humidity.
• Do not use the sensor on the human body.
• Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under
normal operational conditions. If the sensor is being used in a smoky or dusty environment,
the surface of the sensor will accumulate impurities causing a further decrease in the sensor's
performance.
• The included sensor is not water resistant. Do not allow the sensor to become wet. If the sensor
gets wet, immediately remove the sensor from the unit and wipe it with a clean cloth as soon as
possible. Then allow the sensor to dry in normal room temperature before using it again.
• When using the THA-3001 or THA-3151(option) in an environment where the humidity is under
30 %RH, the measurements may sometimes uctuate. This is not abnormal.
• Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides
for High Precision Temperature/Humidity Sensors)
Package Contents
TR-71wf
TR-71wf Temperature Sensor
TR-0106 x 2
AA Alkaline Battery
(LR6) x 2
Manual Set (Warranty
Included) x 1
Registration
Code Label
TR-72wf
TR-72wf Temperature / Humidity
Sensor
THA-3001 x 1
AA Alkaline Battery
(LR6) x 2
Manual Set (Warranty
Included) x 1
Registration
Code Label
TR-72wf-H
TR-72wf High Precision
Temperature/Humidity
Sensor
HHA-3151 x 1
AA Alkaline Battery
(LR6) x 2
Manual Set (Warranty
Included) x 1
Registration
Code Label
2013. 08 16504930001 (1st Edition)
Specications
TR-71wf TR-72wf TR-72wf-H
Sensor (External)
(*1)
TR-0106 THA-3001 HHA-3151 (High-Precision Type)
Thermistor Thermistor Polymer
Resistance
Platinum
Resistance
Electrostatic Capacitance
Measurement
Channels
Temperature 2ch Temperature
1ch
Humidity 1ch Temperature 1ch Humidity 1ch
Measurement Range
-40 to 110°C (Supplied Sensor)
-60 to 155°C
(Optional Sensor: Fluo-
ropolymer Coated Type)
0 to 55°C 10 to 95 %RH -30 to 80°C 0 to 99 %RH
Accuracy Avg. ± 0.3°C
[-20 to 80°C]
Avg. ± 0.5°C
[-40 to -20°C / 80 to 110°C]
± 0.5°C ± 5%RH
[at 25°C,
50%RH]
±0.3°C
[0 to 50°C]
± 0.5°C
[all other tempera-
tures]
± 2.5%RH
[at 25°C, 10 to 85%RH]
± 4.0%RH
[at 25°C, 0 to 10% or 85
to 99%RH]
At temperatures other
than 25°C and ≥ 0°C,
add ±0.1%RH per degree
of difference from 25.
Humidity Hysteresis
±1.5%RH or lower (*2)
Measurement
Resolution
0.1°C 0.1°C 1%RH 0.1°C 0.1%RH
Responsiveness Thermal Constant Time:
Approx. 75 sec.
Response Time (90%):
Approx. 190 sec.
Response Time (90%):
Approx. 7 min.
Response Time
(90%):
Approx. 7 min.
Response Time (90%):
Approx. 20 sec.
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode Endless (Overwrite oldest data when capacity is full)
One Time (Recording automatically stops when capacity is full)
Auto-upload Interval Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
Communication
Interfaces
Wireless LAN Communication
Standard: IEEE 802.11b
Security (*3): WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES)
WPS 2.0: Push Button Conguration
Protocol: HTTP, DHCP, DNS
USB Communication (*4)
USB 2.0 (Mini-B connector)
Power AA Alkaline Battery x 2 (AA Ni-MH batteries may also be used), USB Bus Power (5V 200mA)
Battery Life (*5) With wireless LAN communication: Approx. 10 days to 2 years (Example: Approx. 1 year when Auto-upload
Interval is 1 hour)
Without wireless LAN communication: Approx. 2 years
Dimensions H 58 mm x W 78 mm x D 26 mm
Weight Approx. 100 g (including batteries)
Operating Environment
Temperature: -10 to 60°C Humidity: 90 %RH or less (no condensation)
Software
Compatible OS (*6) Microsoft Windows 8 32 / 64bit (*7)
Microsoft Windows 7 32 / 64bit
Microsoft Windows Vista 32 bit (SP1 or later)
Microsoft Windows XP 32 bit (SP3 or later)
Android 2.2 or later
iOS 5.0 or later
Display Languages
(*8)
English
*1: With the TR-71wf, it is also possible to measure temperature with the internal sensor. However, the measurement range is restricted to the
operating environment for the whole device.
*2: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%,
sensor hysteresis may uctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal
measurement capability.
*3: The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the
WPS feature, please select WPA2-PSK(AES) or disable wireless security.
*4: Optional USB Mini-B Cable US-15C is required for USB communication.
*5: Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval,
and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual
battery life.
*6: For installation, it is necessary to have Administrator (Computer Administrator) rights.
*7: If you are using Windows 8, please note that our software is designed to be used in "Desktop" mode only.
The specications listed above are subject to change without notice.
Options Unit: mm
Temperature Sensors (For TR-71wf) ------------------------------------------
Materials Thermistor TPE Resin TPE Resin-Shielded Wire M3 Crimp Terminal
Compaction Tube Stainless Pipe (SUS304) Stainless Pipe (SUS316)
Temperature
Measurement Range
-40 to 110°C
Sensor Temperature Durability -50 to 115°C
Temperature
Measuring Accuracy
Avg. ±0.3°C [-20 to 80°C], Avg. ±0.5°C [-40 to -20/ 80 to 110°C]
Waterproof Capacity None (Only the stainless pipe is waterproof)
TR-0106 TPE Resin-Shielded Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 190 sec. (in air)
TR-0206 Screw-down Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 210 sec. (in air)
TR-0306 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 11 sec. (in agitated water)
TR-0406 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 15 sec. (in agitated water)
TR-0506 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 10 sec. (in agitated water)
TR-0706 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 11 sec. (in agitated water)
Temperature Sensors: Fluoropolymer Coated Type (For TR-71wf) --------
Materials Thermistor Stainless pipe (SUS316) Fluoropolymer Compaction Tube
Fluoropolymer-Coated Electrical Wire
Temperature Measurement
Range
-60 to 155°C
Sensor Temperature Durability -70 to 180°C
Temperature Measuring
Accuracy
Avg. ± 0.5°C [40 to 80°C], Avg. ± 1.0°C [-60 to -40°C / 80 to 100°C], Avg. ± 2.0°C
[100 to 155°C]
Waterproof Capacity IPX7 immersion proof (sensor/cable)
TR-1106 Fluoropolymer Coated Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 80 sec. (in air) / Approx. 7 sec.
(in agitated water)
Stainless Protection Sensor TR-1220
Cable Length: 2 m
Response Time (90%): Approx. 150 sec. (in air) / Approx. 7 sec.
(in agitated water)
Stainless Protection Sensor TR-1320
Cable Length: 2 m
Response Time (90%): Approx. 90 sec. (in air) / Approx. 3 sec.
(in agitated water)
Temperature/Humidity Sensors (For TR-72wf) ------------------------------
* Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides for High Precision Temperature/Humid-
ity Sensors)
* Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under normal operational conditions. If the sensor is
being used in a smoky or dusty environment, the surface of the sensor will accumulate impurities causing a further decrease in the sen-
sor's performance.
THA-3001 THA-3151 HHA-3151
Materials Temp/Humidity Sensor Polypropylene Resin Polycarbonate Vinyl Chloride
Coated Electrical Wire
Temperature
Measurement Range
0 to 55°C -30 to 80°C
Humidity
Measurement Range
10 to 95 %RH 0 to 99 %RH
Temperature Measuring
Accuracy
± 5°C
[at 25°C, 50%RH]
±0.3°C [0 to 50°C], ±0.5°C [at all other temperatures]
Humidity
Measuring Accuracy
± 5%RH
[at 25°C, 50%RH]
±2.5% (at 25°C, 10 to 85%RH), ±4.0 %RH [at 25 °C, 0 to
10 %RH or 85 to 99 %RH]
At temperatures other than 25°C and ≥ 0°C, add
±0.1%RH per degree of difference from 25.
Humidity Hysteresis: ±1.5 %RH or lower
Waterproof Capacity None
THA-3001 Temperature/Humidity Sensor
THA-3151 Temperature/Humidity Sensor (Cable Type)
Cable Length: 1.5 m
HHA-3151 High Precision Temperature/Humidity
Sensor
Cable Length: 1.5 m
Sensor Extension Cable --------------------------------------------------------
TR-1C30 Extension Cable
Cable Length: 3 m
Materials: Vinyl Coated Electrical Wire
* Only one extension cable per sensor.
* Possible to use up to three extension cables per temperature/humidity sensor
Others ----------------------------------------------------------------------------
US-15C USB Communication Cable TR-07K2 Wall Attachment
Cable Length: 1.5 m Materials: Polycarbonate
Included: Screw x 2 and Double-sided Tape x 1
SO-15C1 ソフトウェアセット
パッケージ内容 :
ソフトウェア CD-ROM x1
USB 通信ケーブル (US-15C) x1
Important Notices and Disclaimers
In order to properly use this product, please carefully read all documents that accompany the product before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your comput-
er that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside
the conditions for free repair outlined in the attached warranty.
• All rights of the attached documents belong to T&D Corporation. It is prohibited to use, duplicate and/or arrange a
part or whole of the attached documents without the permission of T&D Corporation.
• Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other
countries.
• Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and/or
other countries.
• All registered trademarks, company names, product names and logos mentioned herein or for products being used
are the property of T&D Corporation or of their respective owners.
• Specications, design and other contents outlined in the attached documents are subject to change without notice.
• Please follow the safety precautions outlined in the attached documents carefully. We cannot guarantee nor are we
responsible for safety if this product is used in any manner other than was intended.
• On-screen messages in the attached documents may vary slightly from the actual messages.
• Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear
explanations in the attached documents.
• T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
• Accompanying documents cannot be reissued, so please keep them in a safe place.
• Please read the warranty and provisions for free repair carefully.
TR-7wf Series Warranty
Product under Warranty
(Excluding Accessories) TR-71wf TR-72wf TR-72wf-H
Warranty Period 1 year from date of purchase
Date of Purchase
Customer's name
Address
Phone No.
Distributor's name
Address
Phone No.
Object of Repair Main Unit (excluding sensors and any other options.)
Method of Repair Send in for Repair
Provisions for Free Repair
1. If the unit does not work properly despite the fact that the customer used it properly and in line with the manual, the Unit shall be repaired free
of charge through the distributor which sold the unit.
2. If the customer requests free repair because of trouble within the warranty period, bring or send the unit along with the warranty to the
distributor.
3. If you have moved after purchasing, or there are difculties contacting the distributor from which you purchased the unit, please contact T&D
directly for service.
4. Free repair is not available in the following cases even though it is within the warranty period:
1. Trouble or damage was caused by careless operation, natural disaster, re, public pollution, or use of a power source other than specied.
2. If repair, adjustment, disassembly or modication of the unit has been carried out by a person other than a T&D authorized engineer.
3. Trouble or damage was caused by transportation, movement or dropping of the unit after purchase.
4. Failure to submit the warranty or failure to ll in all items required in the warranty.
5. The warranty cannot be reissued.
This warranty only promises customers free repair within the period and conditions claried in this warranty. Therefore, the customer's legal
rights will not be limited by this warranty. For further information on repair and other service questions after the termination of the warranty
period, contact your distributor.
For product information or questions contact us at:
For product inquiries, please contact your local distributor. Visit T&D Website for the distributors list.
If you can not nd a distributor in your area, please contact our main ofce in Japan or one of our
branch ofces in Europe or America.
http://www.tandd.com/about_tandd/contactus/

This manual suits for next models

4

Other T&D Data Logger manuals

T&D TR-701NW Instruction sheet

T&D

T&D TR-701NW Instruction sheet

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D RTR-53A User manual

T&D

T&D RTR-53A User manual

T&D RTR500BW User manual

T&D

T&D RTR500BW User manual

T&D TR71A User manual

T&D

T&D TR71A User manual

T&D RTR500BW Instruction sheet

T&D

T&D RTR500BW Instruction sheet

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR-7wf Series Guide

T&D

T&D TR-7wf Series Guide

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR-5xU Series User manual

T&D

T&D TR-5xU Series User manual

T&D RTR-53 User manual

T&D

T&D RTR-53 User manual

T&D RTR-500DC User manual

T&D

T&D RTR-500DC User manual

T&D TR-71U User manual

T&D

T&D TR-71U User manual

T&D RTR-600 Series User manual

T&D

T&D RTR-600 Series User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D RTR-601 Series User manual

T&D

T&D RTR-601 Series User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR-61 User manual

T&D

T&D RTR-61 User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D TR-71W User manual

T&D

T&D TR-71W User manual

T&D RTR502B User manual

T&D

T&D RTR502B User manual

T&D RTR-501 User manual

T&D

T&D RTR-501 User manual

Popular Data Logger manuals by other brands

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

Aquametro

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

FRO­NIUS Datalogger Web operating instructions

FRO­NIUS

FRO­NIUS Datalogger Web operating instructions

iSens makseNSE ILOGGER CASE user manual

iSens

iSens makseNSE ILOGGER CASE user manual

Intempco CX600 Series manual

Intempco

Intempco CX600 Series manual

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

Furuno VR-7000S installation manual

Furuno

Furuno VR-7000S installation manual

Fluke 1742 Quick reference guide

Fluke

Fluke 1742 Quick reference guide

SOMMER MRL-7 user manual

SOMMER

SOMMER MRL-7 user manual

Aim HYDRA EMS NEMESIS 2.5 Interface connections

Aim

Aim HYDRA EMS NEMESIS 2.5 Interface connections

sauermann Class 320 user manual

sauermann

sauermann Class 320 user manual

METER EM50 Series quick start guide

METER

METER EM50 Series quick start guide

Triplett SLDL20 user manual

Triplett

Triplett SLDL20 user manual

Data Harvest EASYSENSE Q Advanced manual

Data Harvest

Data Harvest EASYSENSE Q Advanced manual

LogTag UTRED30-WiFi Product user guide

LogTag

LogTag UTRED30-WiFi Product user guide

Datafox Evo 4.6 FleKey manual

Datafox

Datafox Evo 4.6 FleKey manual

SATO SK-L751-21 instruction manual

SATO

SATO SK-L751-21 instruction manual

ALAT UJI HOBO UX120-017 manual

ALAT UJI

ALAT UJI HOBO UX120-017 manual

LogTag USRID-16 quick start guide

LogTag

LogTag USRID-16 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.