Please Read First TR-701NW / 701AW
TR-702NW / 702AW
TR-702NW-H / 702AW-H
Part Names and Functions
[RIGHT SIDE]
TR-701NW / 702NW TR-701AW / 702AW
[FRONT]
[BOTTOM]
[LEFT SIDE]
Sensor Jack
Channel 1
For connecting a sensor REC/STOP Button* Press to start or stop recording.
External Output
Terminal
For connecting a siren, buzzer, or
other warning device.
USB Port For connecting to PC with USB cable
Sensor Jack
Channel 2
For connecting a sensor
(TR-701NW / 701AW only)
100/10 Indicator LED The orange LED will be on or off to indicate
the communication speed.
ON: 100Mbps, OFF: 10 Mbps
Battery Case Insert backup battery here.
LAN Port
For connecting LAN cable
POWER Button* Press to turn ON or OFF the device. LINK Display LED If properly connected to a network device
such as a hub, the LED will be on (green).
DISPLAY Button* Press to change LCD display mode. Power Monitor LED While power is ON, the LED will be on (green).
INTERVAL
Button*
Press to make or change recording
interval settings or view currently
set recording interval.
AC Adaptor Jack For connecting the supplied AC adaptor
* When [Button Lock] has been set to "ON" in the Settings Utility, the operation buttons will not be active.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for
protecting yourself and other people from bodily harm and/or damage to property.
Explanation of Symbols
<Warning Symbols>
DANGER These entries are actions that, if taken, may cause serious personal
physical damage or death.
CAUTION These entries are actions that if taken may lead to physical injury or
damage to persons or things.
Explanation of Picture Symbols
Denotes an important
warning or caution.
Denotes a forbidden
action.
Denotes an action that
should be carried out.
DANGER To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and accessories.
Do not use the unit in any environment that is exposed to chemicals and harmful gases.
Doing so may cause corrosion and/or other danger to the unit. Also, coming in contact
with hazardous substances may cause bodily harm to the user or people nearby.
This unit is not water resistant. If water or a foreign object enters the case, immediately
unplug the AC adaptor and stop using it.
Do not handle the unit, remove the battery or unplug the AC adaptor with wet hands.
This product has been designed for private and/or industrial use only. It should not be
used in situations where strict safety precautions are necessary such as with medical
equipment, or in systems directly or indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.
Do not connect any communication cables connected to the unit to telephone line outlets.
Continued use may cause re or electrocution.
Do not cut or process the cords for the AC adaptor or the communication cables. Also, do
not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static electricity from your
body by touching metal around you (such as a door knob and window frame) before
touching the unit.
Place and store the unit and accessories out of the reach of children.
We are not responsible for any damage, malfunction or trouble, whether direct or indirect,
caused by the use of our product.
Do not use any power, battery, sensor, or cable other than those specied by T&D
Corporation.
Do not put anything on top of the cable and/or AC adaptor. This may cause overheating.
Do not disconnect the communication cable during USB, LAN, or wireless communication.
Doing so may cause adverse effects to the unit and/or PC.
Make sure that AC adaptor, sensor, and cable plugs are all inserted fully, so as not to
cause an improper connection. Also, when unplugging the cable from the unit, do not pull
the cord, but hold the connector to disconnect.
If the unit produces heat, emits smoke or a strange smell, or makes unusual noises,
immediately unplug the AC adaptor, remove the batteries, and stop using it. Also, unplug
the unit from the PC.
If the unit is not to be used for a long period of time, remove batteries. If left in the unit, the
batteries may leak and lead to malfunctioning. Install new batteries when starting or
re-starting to use a unit.
CAUTION Do not place or store in the following areas:
• Areas exposed to direct sunlight
• Areas exposed to excessive heat or high
temperatures such as near re or heating
equipment
• Areas exposed to static electricity
• Areas exposed to strong magnetic elds
• Areas exposed to dampness
• Areas subject to condensation or wet areas
• Areas exposed to excessive vibration
• Areas exposed to excessive smoke, dust or
dirt.
CAUTION Other Precautions
• Use the unit in the specied operating environment. Do not use it for any purpose other than for
which it was designed.
• Condensation may occur inside the case when a unit is moved from one environment to another
where there is a great difference in temperature.
• Do not use the unit in wet areas or places exposed to water such as bathroom.
• When connecting the unit to your PC, make sure to follow all warnings and directions from your
computer manufacturer.
• We shall not guarantee the unit's operation if it has been connected to a PC using a USB hub or
a USB extension cable.
• Do not insert any foreign objects into any of the units' jacks.
• If the unit gets dirty, wipe it with a clean cloth.
• Make sure to remove dust and dirt from plugs of the AC adaptor and/or any cables.
• Battery terminals may provide insufcient contact due to age or vibration. This may lead to data
loss.
• If the unit is not to be used for a long period of time, for safety reasons please remove the
battery. If left in the unit, the battery may leak and lead to malfunctioning.
• Please note that this Introductory Manual has been written based on the presupposition that
details about contracts with an Internet provider, specic network environments and the set-up
of any other necessary equipment to enable network connection has already been taken care
of by the User and that connection has been conrmed as workable. T&D Corporation shall not
be responsible for any damages which a contractor, a user or a third party may suffer, whether
direct or indirect, due to the inability to communicate or use communication devices.
CAUTION Notices about Sensors
• Do not connect any sensor to the unit other than those specied by T&D Corporation.
• Make sure to use sensors within the measurement range indicated in the specications for that
sensor.
• If extremely severe temperature changes occur, it may result in large errors in humidity
measurement. Once the sensor's temperature becomes stable, the measurements will return to
normal.
• Do not connect the sensor to any data logger other than those specied by T&D Corporation.
• Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy
and cause damage or malfunction.
• When the sensor is not to be used for a long period of time, please store it at normal
temperature and humidity.
• Do not use the sensor on the human body.
• Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under
normal operational conditions. If the sensor is being used in a smoky or dusty environment,
the surface of the sensor will accumulate impurities causing a further decrease in the sensor's
performance.
• The included sensor is not water resistant. Do not allow the sensor to become wet. If the sensor
gets wet, immediately remove the sensor from the unit and wipe it with a clean cloth as soon as
possible. Then allow the sensor to dry in normal room temperature before using it again.
• When using the THA-3151 in an environment where the humidity is under 30 %RH, the
measurements may sometimes uctuate. This is not abnormal.
• Do not expose to condensation, dampness, corrosive gases, or organic solvents (or insecticides
for High Precision Temperature/Humidity Sensors).
Package Contents
TR-701NW / 701AW
TR-701NW / 701AW Temperature
Sensor
TR-0106 x 2
Common Accessories:
LAN Cable LN-20W x 1
(For TR-701NW / 702NW only)
USB Communication Cable
US-15C x 1
AC Adaptor
AD-0638 or AD-06C1 x 1
Software CD-ROM x 1
Coin Type Lithium Battery
CR-2032 x 1
Manual Set (Warranty Included) x 1
- Getting Started Guide
- Please Read First
TR-702NW / 702AW
TR-702NW / 702AW Temperature /
Humidity Sensor
THA-3151 x 1
TR-702NW-H / 702AW-H
TR-702NW / 702AW Temperature /
Humidity Sensor
HHA-3151 x 1
2014.09 16504900008 (2nd Edition)
Specications
TR-701NW / 701AW TR-702NW / 702AW TR-702NW-H / 702AW-H
Sensor (External) TR-0106 THA-3151 HHA-3151 (High-Precision Type)
Thermistor Thermistor Polymer
Resistance
Platinum
Resistance
Electrostatic Capacitance
Measurement
Channels
Temperature 2ch Temperature 1ch, Humidity 1ch Temperature 1ch, Humidity 1ch
Units of
Measurement
°C, °F °C, °F %RH °C, °F %RH
Measurement
Range
-40 to 110°C (supplied sensor)
-60 to 155°C
(Optional Sensor:
Fluoropolymer Coated Type)
0 to 55°C 10 to 95 %RH -30 to 80°C 0 to 99 %RH
Accuracy Avg. ± 0.3°C
[-20 to 80°C]
Avg. ± 0.5°C
[-40 to -20°C / 80 to 110°C]
± 0.5°C ± 5%RH
[at 25°C, 50%RH]
± 0.3°C
[10 to 50°C]
± 0.5°C
[all other
temperatures]
± 2.5%RH
[at 25°C, 10 to 85%RH]
± 4.0%RH
[at 25°C, 0 to 10% or 85 to
99%RH]
At temperatures other
than 25°C and ≥ 0°C, add
±0.1%RH per degree of
difference from 25.
Humidity Hysteresis
±1.5%RH or lower *1
Measurement
Resolution
0.1°C 0.1°C 1%RH 0.1°C 0.1%RH
Responsiveness Thermal Constant Time:
Approx. 75 sec.
Response Time (90%):
Approx. 190 sec.
Response Time (90%): Approx. 7
min.
Response
Time (90%):
Approx. 7 min.
Response Time (90%):
Approx. 20 sec.
Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode Endless (Overwrite oldest data when capacity is full)
Communication
Interfaces
- TR-701NW/702NW: Wired LAN
RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X
- TR-701AW/702AW: Wireless LAN
Internal wireless LAN antenna IEEE 802.11b / g WEP(64bit/128bit) /WPA-PSK (TKIP) /WPA2-PSK (AES)
- USB Communication (For Setup)
External Alarm
Terminal
<Output Terminal: Photo Mos Relay Output>
Voltage when OFF: AC/DC less than 50V
Current when ON: less than 0.1 A
Resistance when ON: about 35Ω
Communications
Protocol
HTTP, SMTP (POP before SMTP, SMTP-AUTH <LOGIN>), FTP, SNTP, DHCP, DNS
Power Main Power: AC Adaptor (AD-0638 or AD-06C1) / Backup Power: Coin Type Lithium Battery (CR-2032) *2
Data Backup*3 Approx. 3 months (backup battery only without AC adaptor)
Dimensions H 55 × W 78 × D 37 mm
Weight TR-701NW / 702NW / 702NW-H : approx. 82 g,
TR-701AW / 702AW / 702AW-H : approx. 80 g (including battery, excluding sensor)
Operating
Environment
Temperature: -10 to 60°C, Humidity: 20 to 80%RH (no condensation)
Software TR-700W for Windows
Compatible OS
*4*
Microsoft Windows 8 32 / 64bit English*5
Microsoft Windows 7 32 / 64bit English
Microsoft Windows Vista 32 bit (SP1 or later) English
Supported
Browsers *6
<Desktop Browser>
Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later)
<Mobile Browser>
Safari (iOS), Chrome (iOS, Android), Firefox (Android)
Other (*7) The Microsoft .NET Framework 4 Client Prole is required.
*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C 50%, 70°C 35%, and 80°C 25%,
sensor hysteresis may uctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal
measurement capability.
*2: The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot
occur when using only the battery.
*3: Battery life varies depending upon the ambient temperature and the battery performance. All estimates are based on operations carried
out with a new battery and are in no way a guarantee of actual battery life.
*4: For installation, it is necessary to have Administrator (Computer Administrator) rights.
*5: If you are using Windows 8, please note that our software is designed to be used in "Desktop" mode only.
*6: The latest information on supported browsers are available on our T&D Website.
*7: During the installation process of the software, if not present, .NET Framework 4 Client Prole will be installed automatically.
The specications listed above are subject to change without notice.
Notices about using this Product
In order to properly use this product, please carefully read all documents that accompany the product before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer
that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the
conditions for free repair outlined in the attached warranty.
• All rights of the attached documents belong to T&D Corporation. It is prohibited to use, duplicate and/or arrange a
part or whole of the attached documents without the permission of T&D Corporation.
• Microsoft® and Windows® are registered trademarks of Microsoft Corporation USA and are binding in the USA,
Japan and all other countries.
• Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States, Japan,
and/or other countries.
• All registered trademarks, company names, product names and logos mentioned herein or for products being used
are the property or registered property of T&D Corporation or of their respective owners.
• Specications, design and other contents outlined in the attached documents are subject to change without notice.
• Please follow the safety precautions outlined in the attached documents carefully. We cannot guarantee nor are we
responsible for safety if this product is used in any manner other than was intended.
• On-screen messages in the attached documents may vary slightly from the actual messages.
• Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear
explanations in the attached documents.
• T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
• Accompanying documents cannot be reissued, so please keep them in a safe place.
• Please read the warranty and provisions for free repair carefully.
For product information or questions contact us at:
For product inquiries, please contact your local distributor. Visit T&D Website for the distributors list.
If you can not nd a distributor in your area, please contact our main ofce in Japan or one of our
branch ofces in Europe or America.
http://www.tandd.com/about_tandd/contactus/
Options
Temperature Sensor (For TR-701NW / 701AW) --------------------------------
Materials Thermistor TPE Resin TPE Resin-Shielded Wire M3 Crimp Terminal
Compaction Tube Stainless Pipe (SUS304) Stainless Pipe (SUS316)
Temperature Measurement Range -40 to 110°C
Sensor Temperature Durability -50 to 115°C
Temperature Measuring Accuracy Avg. ± 0.3°C [-20 to 80°C], Avg. ± 0.5°C [-40 to 20°C / 80 to 110°C]
Waterproof Capacity None (Only the stainless pipe is waterproof)
Unit: mm
TR-0106 TPE Resin-Shielded Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 190 sec. (in air)
TR-0206 Screw-down Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 210 sec. (in air)
TR-0306 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 11 sec. (in agitated water)
TR-0406 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 15 sec. (in agitated water)
TR-0506 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 10 sec. (in agitated water)
TR-0706 Stainless Protection Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 11 sec. (in agitated water)
Temperature Sensor: Fluoropolymer Coated Type (For TR-701NW / 701AW
) -----
Materials Thermistor Stainless pipe (SUS316) Fluoropolymer Compaction Tube
Fluoropolymer-Coated Electrical Wire
Temperature Measurement Range -60 to 155°C
Sensor Temperature Durability -70 to 180°C
Temperature Measuring Accuracy Avg. ± 0.5°C [-40 to 80°C], Avg. ± 1.0°C [-60 to -40°C / 80 to 100°C], Avg. ± 2.0°C [100
to 155°C]
Waterproof Capacity IPX7 immersion proof (sensor/cable)
TR-1106 Fluoropolymer Coated Sensor
Cable Length: 0.6 m
Response Time (90%): Approx. 80 sec. (in air) / Approx. 7 sec.
(in agitated water)
Stainless Protection Sensor TR-1220
Cable Length: 2 m
Response Time (90%): Approx. 150 sec. (in air) / Approx. 7 sec.
(in agitated water)
Stainless Protection Sensor TR-1320
Cable Length: 2 m
Response Time (90%): Approx. 90 sec. (in air) / Approx. 3 sec.
(in agitated water)
Sensor Extension Cable ----------------------------------------------------------
TR-1C30 Extension Cable
Cable Length: 3 m
Materials: Vinyl Coated Electrical Wire
* Only one extension cable per temperature sensor. Using an extension cable may lead to measurement errors of +0.3°C at room
temperature, and +0.5°C at -50°C.
* Possible to use up to three extension cables per temperature/humidity sensor
Temperature/Humidity Sensor (For TR-702NW / 702AW) --------------------
THA-3151 Temperature/Humidity Sensor
Cable Length: 1.5 m
Materials: Temp/Humidity Sensor Polypropylene Resin
Vinyl Chloride Coated Electrical Wire
Conditions for Use: Do not expose to condensation, dampness,
corrosive gases or organic solvents.
HHA-3151 High Precision Temperature/Humidity
Sensor
Cable Length: 1.5 m
Materials: Temp/Humidity Sensor Polycarbonate Vinyl
Chloride Coated Electrical Wire
Conditions for Use: Do not expose to condensation, dampness,
corrosive gases or organic solvents.
AC Adaptor -------------------------------------------------------------------------
AD-0638 (for US) / AD-06C1 (for EU) AC adaptor
Cable Length: 1.8 m
Input Voltage: AC100 to 240V 50/60Hz
Output Voltage (AD-0638): DC6V 500mA
Output Voltage (AD-06C1): DC6V 1A

This manual suits for next models

5

Other T&D Data Logger manuals

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D RTR-71 User manual

T&D

T&D RTR-71 User manual

T&D TR-7 Series User manual

T&D

T&D TR-7 Series User manual

T&D RTR-501 User manual

T&D

T&D RTR-501 User manual

T&D RTR-501 User manual

T&D

T&D RTR-501 User manual

T&D TR-71W User manual

T&D

T&D TR-71W User manual

T&D RTR-53 User manual

T&D

T&D RTR-53 User manual

T&D RTR-600 Series User manual

T&D

T&D RTR-600 Series User manual

T&D TR-7wf Series Instruction sheet

T&D

T&D TR-7wf Series Instruction sheet

T&D RTR-601 Series User manual

T&D

T&D RTR-601 Series User manual

T&D TR7 Series User manual

T&D

T&D TR7 Series User manual

T&D RTR-500DC User manual

T&D

T&D RTR-500DC User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D TR-7wf Series Guide

T&D

T&D TR-7wf Series Guide

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D RTR-57U User manual

T&D

T&D RTR-57U User manual

T&D RTR-53A User manual

T&D

T&D RTR-53A User manual

T&D TR-74Ui User manual

T&D

T&D TR-74Ui User manual

T&D TR-5xU Series User manual

T&D

T&D TR-5xU Series User manual

T&D TR-71U User manual

T&D

T&D TR-71U User manual

T&D RTR-600 Series User manual

T&D

T&D RTR-600 Series User manual

Popular Data Logger manuals by other brands

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

Aquametro

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

FRO­NIUS Datalogger Web operating instructions

FRO­NIUS

FRO­NIUS Datalogger Web operating instructions

iSens makseNSE ILOGGER CASE user manual

iSens

iSens makseNSE ILOGGER CASE user manual

Intempco CX600 Series manual

Intempco

Intempco CX600 Series manual

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

Furuno VR-7000S installation manual

Furuno

Furuno VR-7000S installation manual

Fluke 1742 Quick reference guide

Fluke

Fluke 1742 Quick reference guide

SOMMER MRL-7 user manual

SOMMER

SOMMER MRL-7 user manual

Aim HYDRA EMS NEMESIS 2.5 Interface connections

Aim

Aim HYDRA EMS NEMESIS 2.5 Interface connections

sauermann Class 320 user manual

sauermann

sauermann Class 320 user manual

METER EM50 Series quick start guide

METER

METER EM50 Series quick start guide

Triplett SLDL20 user manual

Triplett

Triplett SLDL20 user manual

Data Harvest EASYSENSE Q Advanced manual

Data Harvest

Data Harvest EASYSENSE Q Advanced manual

LogTag UTRED30-WiFi Product user guide

LogTag

LogTag UTRED30-WiFi Product user guide

Datafox Evo 4.6 FleKey manual

Datafox

Datafox Evo 4.6 FleKey manual

SATO SK-L751-21 instruction manual

SATO

SATO SK-L751-21 instruction manual

ALAT UJI HOBO UX120-017 manual

ALAT UJI

ALAT UJI HOBO UX120-017 manual

LogTag USRID-16 quick start guide

LogTag

LogTag USRID-16 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.