PACEMAKERS
Some products contain Neodymium MAGNETS, which may interfere with devices
such as pacemakers, ICD’s and any other device sensive to magnec elds. It is
STRONGLY recommended that owners of such medical devices consult their physician
prior to using products that contain Neodymium MAGNETS. It is also possible that
some pacemakers may falsely interpret the oponal massage feature vibraons as
movement/exercise. This is a common occurrence with any product that creates a
vibrang movement and may aect the pacemaker. Please consult your physician
before using the massage feature.
IN-HOME USE AND HOSPITAL STANDARDS
Ergomoon adjustable bed bases are designed solely for in-home use. This base was not
designed as a hospital bed and is not designed to meet hospital standards. Do not use
this base with TENT TYPE oxygen therapy equipment or near explosive gases.
ADDITIONAL SAFETY FEATURES
Casters (oponal leg accessory) are equipped with locking wheels to prevent unwanted
movement. Even when locked and unable to roll, it is possible for the casters to slide.
Free release head and foot motors are designed to lower the maress by retracng
only with gravity, never pulling downwards, which minimizes pinch points.
ACOUSTICS
LIFTING/LOWERING MECHANISMS
The li/lower feature will emit a minimal humming sound during operaon. This is
normal. During operaon, the li arm wheels make contact with the plaorm support
of the base. This contact may result in metal on metal or metal on plasc contact.
This applies slight tension on the moving components and resonance is reduced to a
minimum level. If excessive noise or vibraon is experienced, reverse the movement
acon (up or down) of the base with the remote control. This should realign the base’s
acvang mechanisms to the proper operaonal posion. In normal base operaon,
the wheels, which allow the bed to maintain its distance from the wall, will make
contact with the steel plaorm supports of the base creang a contact noise. When
entering, exing or shiing weight on the base, this contact noise may be audible as
the wheels make contact. This is normal.
MATERIALS
Ergomoon adjustable bases are constructed from various materials including woods,
metals, plascs and fabrics. Tension, pressure or movement applied to the frame,
plaorm or shroud through general use may create an audible sound.
TOLERANCE
All Ergomoon adjustable foundaons, depending on make and model, are designed
and manufactured to perform and funcon within designated quality control
parameters. Bases are subject to meculous and rigorous inspecons during the
quality control process to ensure bases will operate within these standards during
normal operang use. Normal operang use is dened as the following: Adjustable
foundaon is to be operated with a maress and load. Tesng procedures require
lifeme cycle tests with up to 120 kg
distributed load. The angle (designated
“a” in gure 1) between the back
secon and the at secon for various
conguraons of the maress support
plaorm shall be ± 3°, which translates to
a tolerance of up to 1 ½”.
The angle (designated “b” in gure
1) between the at secon and foot
safety precauons and usage statements
WARNING
For optimal safety and operation, plug bed base into a surge protector (not included).
The bed base should only be plugged directly into a grounded wall outlet or surge
protector (strongly recommended). Improper connection of the equipment can result in
the risk of electrical shock, electrical file or faulty operation of this bed base. If the plug
does not fit your outlet, contact a qualified Electrician to install a suitable outlet.
Adjustable
Bed Tolerance
Ergomotion Inc. | ph 1-888-550-3746 | fx 805-979-9399 | www.ergomotion.com
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
The angle (designated “α” in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.
The angle (designated “β” in figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾”.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer’s
quality control standards.
(α°)
(β°)
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
Blake Pettit
Quality Assurance Manager
Ph 805-979-3875
Fx 805-979-9399
www.ergomotion.com