1About this document ...........................................................................3
2Safety and disposal..............................................................................3
3Product-specific safety instructions ..................................................3
4Data protection.....................................................................................4
5Use.........................................................................................................4
6Product description .............................................................................5
6.1 Front view...........................................................................................................5
6.2 Rear view ...........................................................................................................6
6.3 Probe connections..............................................................................................6
7Commissioning ....................................................................................7
7.1 Mains unit/energy storage unit ............................................................................7
7.2 Switching the testo 400 on and off ......................................................................7
7.3 Display – user interface ......................................................................................8
8Using the product...............................................................................10
8.1 Overview of main menu ( )............................................................................10
8.2 Overview of measurement types ( )...............................................................12
8.3 Overview – editing the reading display ( ) ....................................................13
8.4 Getting the readings in 5 steps .........................................................................14
9Software ..............................................................................................16
9.1 Purpose ............................................................................................................16
9.2 System requirements........................................................................................16
9.3 First steps.........................................................................................................17
9.3.1 Installing the software/driver.....................................................................................17
9.3.2 Launching testo DataControl ....................................................................................17
9.4 Using the product .............................................................................................18
9.4.1 Overview..................................................................................................................18
9.4.2 Synchronizing data...................................................................................................18
10 Technical data ....................................................................................19
10.1 Product-specific approvals................................................................................20
10.2 Contact and support .........................................................................................20

1 About this document
3
1About this document
•The instruction manual is an integral part of the instrument.
•Keep this documentation to hand so that you can refer to it when necessary.
•Please read this instruction manual through carefully and familiarize yourself
with the product before putting it to use.
•Hand this instruction manual on to any subsequent users of the product.
•Pay particular attention to the safety instructions and warning advice in order
to prevent injury and damage to the product.
You will also find further information about your testo 400 universal IAQ
instrument in the online instruction manual on the Testo website,
www.testo,com, under the product-specific download.
2Safety and disposal
Take the testo information document into account (accompanies the product).
3Product-specific safety instructions
DANGER
Integrated magnet
Danger to life for persons with pacemakers!
-Keep a distance of at least 20 cm between your pacemaker and the
measuring instrument.
ATTENTION
Integrated magnet
Damage to other devices!
-Keep a safe distance from devices that may be damaged by magnetism
(e.g. monitors, computers, credit cards, memory cards, etc.).

4Data protection
4
4Data protection
The testo 400 measuring instrument makes it possible to input and store
personal data such as name, company, customer number, address, telephone
number, e-mail address and website.
Please be aware that your use of the functions offered here is entirely your own
responsibility. This applies in particular to use of the interactive functions (e.g.
storing customer data or sharing readings). You are responsible for compliance
with the data protection regulations and laws applicable in your country.
Therefore it is your responsibility to ensure the legality of the processing of
personal data for which you are responsible.
The personal data collected with the measuring instrument is never
automatically transferred to Testo SE & Co. KGaA.
5Use
The testo 400 is an instrument for measuring climate-related parameters. The
testo 400 is particularly suitable for carrying out comfort level measurements for
workplace evaluation and flow measurements in and on air conditioning
systems.
The instrument is only to be used by qualified expert personnel. The
product must not be used in potentially explosive atmospheres!

6 Product description
5
6Product description
6.1 Front view
1
On/Off and Standby button
2
User interface/Touchscreen (see
Section 9.1)
3
Front camera
4
Connections for probes (see
Section 7.3)

6Product description
6
6.2 Rear view
1
Camera
2
Differential pressure
measurement connections
(+/- marking)
3
Magnets
4
Attachment point for carrying
strap
5
USB port/mains connection
CAUTION
Make sure the pressure tube does not jump away from the connection
socket.
Risk of injury!
-Ensure correct connection.
6.3 Probe connections
1
Thermocouple probe type K
connection (T1 and T2)
2
Connection for probes with
TUC connector (A and B)

7 Commissioning
7
7Commissioning
7.1 Mains unit/energy storage unit
The measuring instrument is supplied with an energy storage unit.
Fully charge the energy storage unit before using the measuring
instrument.
Plug the mains unit USB cable into the USB port on the side.
If the mains unit is connected, the measuring instrument is
automatically powered via the mains unit.
Only charge the energy storage unit at an ambient temperature of 0 to
45 °C.
7.2 Switching the testo 400 on and off
Current
status
Action Function
Instrument off
Press and hold down the
button (> 3 sec)
Instrument is switched on
When the measuring instrument is started for the first time, the setup
wizard guides you through the following setting parameters step by
step:
- Language
- Country
- Units
- WLAN
- Date and time
- Own company address
- E-mail account
After the setup wizard, a tutorial can be launched. The tutorial
demonstrates the general operation and the most important functions of
the measuring instrument using examples.
Instrument on Press the button briefly
(< 1 sec)
Instrument is switched to
standby mode. The instrument
is re-activated when the button
is pressed again.

7Commissioning
8
Current
status
Action Function
Instrument on
Press and hold down the
button (> 1 sec)
Choice: press [OK] to switch the
instrument off or press [Cancel]
to cancel switch-off of the
instrument.
The tutorial can be executed again at any time in the main menu under
Help and Information.
Measuring values that have not been saved are lost when the
measuring instrument is switched off.
7.3 Display – user interface
1
Open main menu
2
Display of the measurement period
3
Display of calculated measurement results
4
Reading for each probe
5
Can be controlled with different function keys
6
Instrument status bar
7
Configuration

7 Commissioning
9
8
Edit reading display
Further symbols on the user interface (without numbering)
One level back
Exit view
Share report
Search
Favourite
Delete
Further information
Display report
Multiple selection

8Using the product
10
8Using the product
8.1 Overview of main menu ( )
Menu Description
Measuring
List with various application-specific
menus
Customer
Create, edit and delete customer and
system information.
Memory
Call up, edit, send, export (different
formats possible) and delete
measurements that have been carried
out.
Sensors
Overview of integrated sensors and
connected probes.
- Adjustment via the input of
calibration information
- Damping
- Serial number
- Firmware version
- Battery level (Bluetooth
®
probe)

8 Using the product
11
Menu Description
Settings
Instrument settings
- Regional settings
- WLAN & e-mail
- Measurement settings
- Company details
- Torch
- Display settings
- Restore factory settings
Help and Information
Aids
- Instrument information (serial
number, app version, firmware
version, update information)
- Tutorial
- Instruction manual
- Exclusion of liability
Additional applications
Additional applications
- Camera
- Clock
- E-mail
- Gallery
- Browser
- Calendar
- Pocket calculator
- QuickSupport
- File manager

8Using the product
12
8.2 Overview of measurement types ( )
Measuring
Basic view
Volume flow - Duct
Volume flow – Duct traverse (EN 12599)
Volume flow – Duct traverse (ASHRAE 111)
Volume flow - Outlet
Volume flow - funnel
Volume flow – Pitot tube
Volume flow – k-factor
Comfort – PMV/PPD (EN 7730 / ASHRAE 55)
Discomfort – Draft rate
Differential temperature (ΔT)
Differential pressure (ΔP)
You will also find further information about the individual measurement
types in the online instruction manual on the Testo website,
www.testo,com, under the product-specific download.

8 Using the product
13
8.3 Overview – editing the reading display
( )
Menu Description
Edit view
The display can be edited for each
connected probe. The available
measurement parameters can be
selected and deselected and the unit
for each parameter can be adjusted.
These changes are saved for the next
measurement.
Zero pressure sensor
Once the testo 400 has been brought
into the operating position for a
differential pressure measurement,
the sensor should be zeroed against
ambient air.
Adjusting Degree of Emission
If the testo 805i is connected, the
selection of emissivity appears here.
This can be set individually depending
on the measuring surface.

8Using the product
14
8.4 Getting the readings in 5 steps
1
Switch instrument on: Press button > 1
sec.
2
Connect probe via cable or
Bluetooth®.
3
Place probe in the application.
4
Start measurement and read off
measuring values.

8 Using the product
15
5
Save and send readings
You will also find further information about your
testo 400 universal IAQ
instrument in the online instruction manual on the Testo website,
www.testo,com, under the product-specific download.

9Software
16
9Software
The testo 400 has a USB port, via which the measuring instrument can be
connected to the PC.
Knowledge of Windows®operating systems is required to work with the
software.
9.1 Purpose
The testo DataControl measurement data management and analysis software
enhances the functionality of the testo 400 measuring instrument with lots of
useful functions:
•Manage and archive customer data and measuring site information
•Read out, evaluate and archive measurement data
•Presenting readings in graphic form
•Create professional measurement reports from the existing measurement
data
•Conveniently add images and comments to measurement reports
•Data import from and data export to the measuring instrument
9.2 System requirements
Administrator rights are required for installation.
Operating system
The software can be run on the following operating systems:
•Windows®7
•Windows®8
•Windows®10
Computer
The computer must meet the requirements of the operating system in each
case. The following requirements must also be met:
•Interface USB 2 or higher
•DualCore processor with minimum 1 GHz
•Minimum 2 GB RAM
•Minimum 5 GB available hard disk space
•Screen with a resolution of at least 800 x 600 pixels

9 Software
17
9.3 First steps
9.3.1 Installing the software/driver
1
Insert the program CD into the CD-ROM drive of the computer.
or
Download the program (www.testo.com/download-center) and unpack
the zip file using a suitable compression tool.
2
Launch the TestoDataControlPCsetup.exe file.
3
Follow the instructions of the installation wizard.
4
Click on [Finish] to complete the software installation.
5
Once the software installation is completed, connect the instrument to
the computer to continue with the driver installation.
6
Use the USB-cable to connect the instrument to the PC.
The connection will be established.
9.3.2 Launching testo DataControl
The user interface of the software is opened in the language of the
operating system, if it is supported. If the operating system language is
not supported, the user interface will be in English.
Windows®program menu
Windows®7:
Click on [Start] | All Programs | Testo | testo DataControl (double-click on left
mouse button).
Windows®8:
Click on [Start] | right mouse button | Search (Enter the application name in the
search field) | testo DataControl (double-click on left mouse button).
Windows®10:
Click on [Start] | All Apps | Testo | testo DataControl (double-click on left
mouse button).
testo DataControl launches automatically.

9Software
18
9.4 Using the product
9.4.1 Overview
1 Main menu 3 Connection status of the
measuring instrument
2
Update notification
4
Multi-function bar
5
Display area
Operation of the software is based on the same functional principle as the
instrument firmware for the testo 400.
You will also find further information about testo DataControl in the
online instruction manual on the Testo website, www.testo,com, under
the product-specific download.
9.4.2 Synchronizing data
1
Synchronization status
2
Display area
The data can be synchronized selectively per customer or as a whole across all
customers simultaneously.

10 Technical data
19
10 Technical data
General
Feature Value
Probe connections
- 2x type K thermocouple
- 2x Testo Universal Connector (TUC) for
connecting cable probes to the
corresponding plug
- 1x differential pressure
- 1x absolute pressure (integrated)
- 4x Bluetooth
®
probe or testo Smart Probe
Interfaces
- Micro USB for connection to PC or for
battery charging with mains unit
- WLAN 802.11 b/g/n
- Bluetooth
®
4.0
Internal memory capacity
2 GB (corresponds to 1,000,000 readings)
Rechargeable battery life
10 hours of continuous operation / 3200 mAh
Measuring cycle
0.5 sec / display update 1 sec
Operating temperature
-5 to +45 °C
Storage temperature
-20 to +60 °C
Charging temperature
0 to +45 °C
Dimensions in mm
186 x 89 x 41 (L x W x H)
Housing material
PC, ABS, TPE
Weight
500 g
Protection class
IP 40 (with probe connected)
Display
5.0 inch HD display (1280*720 pixels)
Camera - Front camera 5.0 MP
- Rear camera 8.0 MP
Integrated sensors (at 22 °C, ±1 digit)
Characteristics Measuring range Accuracy Resolutio
n
Temperature
(TC type K)1
-200 to +1370 °C ±(0.3 °C + 0.1% of m.v.)
Internal cold junction
measurement: ±0.5 °C
0.1 °C
Temperature
(NTC)
-40 to +150 °C
±0.2 °C (-25.0 to
+74.9 °C)
±0.4 °C (-40.0 to -25.1 °C)
±0.4 °C (+75.0 to
+99.9 °C)
±0.5% of m.v. (rest)
0.1 °C

10 Technical data
20
Characteristics Measuring range Accuracy Resolutio
n
Differential
pressure2
-100 to +200 hPa
±(0.3 Pa + 1% of m.v.)
(0 to 25 hPa)
±(0.1 hPa + 1.5 % of m.v.)
(25.001 to 200 hPa)
0.001 hPa
Absolute
pressure
+700 to +1100 hPa
±3 hPa
0.1 hPa
1The accuracy information applies in an adjusted, stable temperature state.
Plugging in the mains unit, charging the battery or adding digital probes can
distort this temporarily, and additional errors may occur.
2The accuracy specification applies immediately after zeroing of the sensor. For
long-term measurements, mains operation with fully-charged battery is
recommended.
10.1 Product-specific approvals
Please find the current approvals in the attached Approval and Certification
document(s).
10.2 Contact and support
If you have any questions or need further information, please contact your
dealer or Testo Customer Service. For contact details, please visit
www.testo.com/service-contact.
Other manuals for 400
4
Table of contents
Other TESTO Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Braebon
Braebon Q-RIP user guide

Extron electronics
Extron electronics M Series manual

Hanna Instruments
Hanna Instruments Gro Line HI9814 instruction manual

MasterGage
MasterGage Classic owner's manual

PCB Piezotronics
PCB Piezotronics 3713B112G Installation and operating manual

Agilent Technologies
Agilent Technologies Flow Tracker 1000 manual