GSM Module Installation Manual
INS227 5
Panel Configuration
Before attempting to use the GSM module it must be correctly configured as follows:
1. Enter “Engineers Programming” mode and select “UDL/Digi Options”, then
select “Com Port Setup”. Ensure Com Port 2 is programmed as “GSM Module”.
2. Now select the “Digi Options” menu and make sure that “Digi Option 1” is
programmed for “Digi is Enabled”.
3. Now select “Program Digi” and ensure the following options are programmed for
one of the ARC options:
a) Protocol: “SMS Messaging”.
b) Primary No: The number of the recipients mobile telephone.
c) Secondary No: Secondary mobile telephone number (if required).
d) Account No: Leave blank.
e) Dialling Attempts: Program as required.
f) Report Areas: Program as required.
g) Reports: Program as required.
h) Config.: Program as required.
4. Select the “Radio/SMS options” menu and scroll down until the display shows
the GSM signal level. Ensure that the level is between –10 and –95 dBm and the
Bit Error Rate (BER) is less than 6.
Using the SMS Control Commands
Control commands can be sent to the GSM module to allow remote control and
integration of the alarm system.
1. Select the send text message option on your mobile telephone.
2. Enter the telephone number of the GSM module.
3. Enter the text command, see SMS Control Commands.
4. Select send on your mobile telephone.
When using the SMS Control Commands shown in the table on the next page the
following should be noted:
???? = User code, this must proceed all commands.
[areas] = Areas 1 to 8 or A to P. If the areas are not specified then all areas will be
selected.
[s] = Send back status report
(zones) = List of zones, each zone must separated by a space e.g. 1 12 167 etc.
(outputs) = List of output, e.g. 1234 etc.
(message) = A maximum of 32 characters.