8. Option Definitions
PULSE COUNT
Thisisthenumberoftimestheunithastodetectonbothofitssensorsbeforesignallinganoutput.
LED MONITOR
LEDOff-LEDdisabled.
LEDOn-LEDsignalsadetection.
N/OPEN & N/CLOSED
Thesearemagneticallyimmunevoltfree relay contacts used to triggeralarminputsonconnected
equipment.Thecontactsareratedatamaximumof24VAC/DC@50mA.
ACCESSORIES
Texecomisabletosupplythefollowingaccessoriestoaidinstallations:
Polemountbracketavailableonrequest.
(JAH-0001)PrestigeOrbitWalkTester.
INS483 8
7. Using the Walk Tester
Remove the cover from the Prestige Orbit housing by
looseningthelockingscrewatthebottomofthedetector.
Thiswillallow accesstothe programmingbuttonshown
inFig.11(andtoalsotoshowthelocationoftheblueIR
emittingLED).
PlacethePrestigeOrbitinto‘walktest’modebypressing
theprogrammebuttononce(Fig.11).ThePrestigeOrbit’s
clearLEDwillthenashoutits current settings. Waitfor
theashingsequencetonish.ThePrestigeOrbitisnow
in walk test mode and will remain in that state for ve
minutesafterthelastdetection,whereafteritwillrevertto
normalmode.Thewalktestcanbecancelledatanytimeby
pressingtheprogrammebuttontwice.
ReplacethePrestigeOrbitcoverandplacetheWalkTesterinthemetalholder.
SlightlyloosenthestainlesssteelscrewonthebottomofthePrestigeOrbit,just
enoughso thatthedrilledtabontheWalkTesterbracketcanslidearoundthe
screwthread.ThengentlytightenthescrewtoholdtheWalkTesterandholderin
place.TurntheWalkTesteron.
The Walk Tester will illuminate and sound every time the Prestige Orbit is
activated.
Whennishedtesting,turnofftheWalkTesterandremoveitandtheholderfrom
thePrestigeOrbit.TightenthescrewonthebaseofthePrestigeOrbit.Theexternal
detectorisnowready.