5
Error display at RAMSES BLE
LIf the external input is set to "fl oor" or "room temperature", an
appropriate temperature sensor has to be connected. If this sen-
sor is missing, the red LED fl ashes at one second intervals.
4. Setting the optimisation
The optimisation function allows you to achieve a certain
room temperature at a desired switching point. The display
shows how many minutes earlier the heating starts. This time
applies per K of temperature difference between actual tem-
perature and desired set temperature.
Example
At 06.00 a.m. in the morning, a change in the bathroom is
programmed from reduction (17 °C) to comfort temperature
(23 °C).
Without optimisation function, the room thermostat enables
the heating request for the bathroom at 06.00 a.m. Depen-
ding on the size of the room and the installed heating system,
the bathroom reaches the desired 23 °C at 6.30 a.m., for
example.
With a set optimisation of 5 min/K, the thermostat sends the
heating request earlier, as follows:
Set temperature at 06.00 a.m. 23 °C
Actual temperature 17 °C
i.e. Delta T = 6 K
6 K * 5 min/K = 30 min
The controller sends the heating start 30 min. earlier and
reaches the setpoint temperature at 06.00 a.m.
LThe optimisation value depends on the spatial and heating
conditions.
5. PIN
This function can be used to assign a new PIN.
•The factory setting for the PIN is 0.
•New PIN can be entered (1–6 digits).
•In case of Delete pairing (2nd pairing), the PIN is set to
0.
•If the PIN is 0, the PIN will not be requested during
pairing.
7. Technical data
Supply voltage: 230 V AC +10 %/–15 %, 50 Hz
Controller type: Hysteresis controller or pulse
duration controller
Contact: Swich contact µ max. 8 (1)
A/250 V AC
Temperature setting range: + 2 °C ... + 30 °C in increments
of 0.2 °C
Memory locations: 42
Protection rating: IP 20 in accordance with EN
60529
Protection class: II in accordance with EN
60730-1
Operating temperature: + 0 °C ... + 50 °C
Power reserve: 4 hours
Mode of operation: Type 1 B in accordance with EN
60730-1
Rated impulse voltage: 4 kV
Pollution degree: 2
Software Class A
Theben AG herewith declares that this type of radio installation
complies with Directive 2014/53/EU. The complete text of the
EU Declaration of Conformity is available at the following Internet
address: www.theben.de/red-konformitaet
8. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Phone +49 7474 692-0
Fax +49 7474 692-150
Hotline
Phone +49 7474 692-369
Addresses, telephone numbers etc.
www.theben.de