manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Toa
  6. •
  7. Control Unit
  8. •
  9. Toa AT-4000 Series User manual

Toa AT-4000 Series User manual

2. CONNECTIONS
1. WIRING DIAGRAMS
Please follow the instructions manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
2-wire connection 3-wire connection 4-wire connection
4. SPECIFICATIONS
Model
Attenuations
Input Capacity
Override Indicator
Overriding Voltage
Dimensions
Weight
Color
Finish
AT-4012 AS AT-4030 AS
AT-4060 AS
12 Watt 30 Watt
60 Watt
8 Steps ( 0 dB, -3dB, -6dB, -9dB, -12dB, -15dB, -18dB, OFF )
Red LED (4-wire connection only)
24V, 11mA DC (4-wire connection only)
86 (W) x 86 (H) x 24 (D) mm 86 (W) x 86 (H) x 51 (D) mm
White (RAL 9016 or equivalent)
Knob, Cover Panel : ABS Resin, White (RAL 9016 or equivalent)
Note:
Back Box is not available for AT-4012 AS.
The design and specifications are subject to change without notice for improvement.
Accessories
Back Box 85.5 (W) x 85.5 (H) x 60 (D) mm ............... 1
Plate mounting screw ............................................... 2
This product can be installed by Surface Mounting or Flush Mounting. We recommend following
step by step to install this product. For better installation, please consult a contractor, dealer, or
professional installer.
3.1. SURFACE MOUNTING
3. INSTALLATIONS
55
55
4 holes
WALL
URL : http://www.toa.com.sg/
Applicable cable :
Range : 22 - 14 AWG
Solid copper wire : 0.6mm - 1.6mm
Stranded copper wire : 0.8mm - 2mm
Unit : mm
Strip the shield of the cable approx. 9mm.
After loosening the screws at terminal
block, insert the core of the cables fully
into the specified terminal block. Tighten
the screws and make sure the cables are
not loose.
To prepare for installation, mark the 4
holes on the wall with the back box as
shown in the picture. For AT-4012 AS
which uses the common electrical box,
check the dimension specifications of the
common electrical box for proper
installation.
Hot In COM
approx. 9 mm
Cable
Core
N.C N.C
Hot In COM
Note : N.C is NOT CONECTED
Terminal
Usable Cable Cable range 22 - 14 AWG
Screw type x 5 ( Terminal )
Front Panel (Plate) : Surface treated steel plate
0.12 Kg 0.45 Kg
0.46 Kg
Model
Attenuations
Input Capacity
Override Indicator
Overriding Voltage
Dimensions
Weight
Color
Finish
AT-4120 AS AT-4200 AS
120 Watt 200 Watt
8 Steps ( 0 dB, -3dB, -6dB, -9dB, -12dB, -15dB, -18dB, OFF )
Red LED (4-wire connection only)
24V, 11mA DC (4-wire connection only)
86 (W) x 86 (H) x 51 (D) mm
White (RAL 9016 or equivalent)
Knob, Cover Panel : ABS Resin, White (RAL 9016 or equivalent)
Terminal
Usable Cable Cable range 22 - 14 AWG
Screw type x 5 ( Terminal )
Front Panel (Plate) : Surface treated steel plate
0.48 Kg 0.49 Kg
AT-4000 SERIESATTENUATOR
INSTALLATION MANUAL
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany
30
Screw M3 X 20
Cover Panel
Main unit attenuator
3.2. FLUSH MOUNTING
Flush mounting installation can be implemented in 2 ways, with back box or without back box.
3.2.1 FLUSH MOUNTING WITH BACK BOX
3.2.2 FLUSH MOUNTING WITHOUT BACK BOX
Install the back box with suitable
screws on the surface of the wall.
Connect the recommended cable to
the terminal.
WARNING :
Do not supply 24V DC when connect-
ing 4-wire attenuator system.
Install the main unit to the back box.
Note :
For AT-4012 AS, the screw size
should be compatible with the
common electrical box specifications.
Attach the cover panel to the main
unit attenuator until the hook mount
clips perfectly.
Cut this area for
the lane cables.
The common back box
Step 1.
Step 2.
Step 3.
Step 4.
Unit : mm
65 - 70
69 - 73
WALL
To prepare for installation, mark the
opening on the wall with rectangular
pattern as shown in the picture. For
AT-4012 AS which uses the common
electrical box, check the dimension
specifications of the common electrical
box for proper installation.
Install the back box inside the wall.
Connect the recommended cable to
the terminal.
WARNING :
Do not supply 24V DC when connect-
ing 4-wire attenuator system.
Install the main unit to the back box.
Note :
For AT-4012 AS, the screw size
should be compatible with the
common electrical box specifications.
Attach the cover panel to the main
unit attenuator until the hook mount
clips perfectly.
Step 1.
Step 2.
Step 3.
Step 4.
Cover Panel
Screw M3 X 20
Main unit Attenuator
Support
To prepare for installation, mark the
opening on the wall as shown in the
picture. This mounting method can be
used for all models.
Make opening on the wall.
Connect the recommended cable to
the terminal.
WARNING :
Do not supply 24V DC when
connecting 4-wire attenuator
system.
Install the main unit directly to the
wall using screws that are suitable
for the kind of wall.
Attach the cover panel to the main
unit attenuator until the hook mount
clips perfectly.
Step 1.
Step 2.
Step 3.
Step 4.
57 - 60
72
34.5 - 36.5
36
2 holes
WALL
Cover Panel
Screw
Main unit Attenuator
69 - 73
Unit : mm
Back Box
Support
4
1
2
3
2
4
3
1
2
4
3
1
Cut this area for
the lane cables.

This manual suits for next models

2

Other Toa Control Unit manuals

Toa IP-100XI User manual

Toa

Toa IP-100XI User manual

Toa AT-063Ap User manual

Toa

Toa AT-063Ap User manual

Toa COBRANET User manual

Toa

Toa COBRANET User manual

Toa AT-4060 AS User manual

Toa

Toa AT-4060 AS User manual

Toa AT-4012B-EB User manual

Toa

Toa AT-4012B-EB User manual

Toa SP-11N User manual

Toa

Toa SP-11N User manual

Toa SX-200IP User manual

Toa

Toa SX-200IP User manual

Toa AC-M1 User manual

Toa

Toa AC-M1 User manual

Toa ZM-9001 User manual

Toa

Toa ZM-9001 User manual

Toa DX-0808 User manual

Toa

Toa DX-0808 User manual

Toa D-2000DA1 User manual

Toa

Toa D-2000DA1 User manual

Toa AC-F1 User manual

Toa

Toa AC-F1 User manual

Toa U-14R User manual

Toa

Toa U-14R User manual

Toa IP-300XI User manual

Toa

Toa IP-300XI User manual

Toa WTU-M9800 User manual

Toa

Toa WTU-M9800 User manual

Popular Control Unit manuals by other brands

Siemens SINUMERIK 840Di Function manual

Siemens

Siemens SINUMERIK 840Di Function manual

Siemens RWF50 Application guide

Siemens

Siemens RWF50 Application guide

ICP DAS USA tPET-P2R2 quick start guide

ICP DAS USA

ICP DAS USA tPET-P2R2 quick start guide

Danfoss PVE 3 Series installation guide

Danfoss

Danfoss PVE 3 Series installation guide

axing SKF 40-00M Operation instructions

axing

axing SKF 40-00M Operation instructions

MAZATROL M PLUS Series Maintenance manual

MAZATROL

MAZATROL M PLUS Series Maintenance manual

ICP DAS USA IR-310-RM user manual

ICP DAS USA

ICP DAS USA IR-310-RM user manual

PERSTA DVA 200 BZ operating instructions

PERSTA

PERSTA DVA 200 BZ operating instructions

Dormakaba MFC installation instructions

Dormakaba

Dormakaba MFC installation instructions

CHENGDU VANTRON TECHNOLOGY AP6255 user manual

CHENGDU VANTRON TECHNOLOGY

CHENGDU VANTRON TECHNOLOGY AP6255 user manual

TLV RT3A instruction manual

TLV

TLV RT3A instruction manual

syscomtec SCT-IPKVM-CX user manual

syscomtec

syscomtec SCT-IPKVM-CX user manual

Eaton CEAG DLS/3PH-BUS-Module-inverse Mounting and operating instructions

Eaton

Eaton CEAG DLS/3PH-BUS-Module-inverse Mounting and operating instructions

Ross openGear FSR-6201 user manual

Ross

Ross openGear FSR-6201 user manual

Fisher ET instruction manual

Fisher

Fisher ET instruction manual

Edge Lighting Controller Dial with Power Supply Operational guide

Edge Lighting

Edge Lighting Controller Dial with Power Supply Operational guide

EOS SBM GLT KNX Installation and operating instructions

EOS

EOS SBM GLT KNX Installation and operating instructions

beier AKL-8-W Operation manual

beier

beier AKL-8-W Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.