WWW.TRAXON-ECUE.COM ©2023 traxon technologies. All rights reserved. Information for Use 06/23 Sheet: 05 / 14
Test / Error O: no error detected.
Short-short-long sequence: Test mode active.
On: If constantly lights in red, an error occurred. This can be an internal error or
malfunction of the device, or an external error, e.g. a shortcut of interface connections or
alien power supply. Switch the device o and on. If the error persists, check the wiring or
contact Traxon e:cue Service.
Status +
Test / Error
The Status and Test / Error LED blink simultaneously to identify the SYMPL Node
(enabled “Identify Interface Mode” in SYMPHOLIGHT).
DMX 1 ... 8 Orange: DMX/RDM data outgoing.
White: e:pix data outgoing.
Blue: data incoming.
Orange + White: port error.
2.4 Identifybutton:Identication&Reset
The Identify button has three functions: to send an Identify message (A), to reset the Node (B), and to exit the
error state (C). For the e:pix version, the Identify button additionally switches protocol during Test mode (D).
(A) Only available with e:net: A short press during operation in online mode sends an Identify message to the
server. This helps to assign the Node in the Setup tab in SYMPHOLIGHT.
(B) The Identify button can also be used to reset the device to factory state or to stay in bootloader mode.
With a reset you restore the password and device settings by using the Identify button. Please note that the
device name is not reset:
yKeep the Identify button pressed while powering up, Status and Test / Error LEDs light up at rst.
Bootloader mode is signaled by a fast blinking Status LED. Release the button now. The device stays in
bootloader mode to download a new rmware.
To exit the bootloader mode, short press the Identify button again.
yPress the Identify button during operation until Status and Test / Error LEDs blink alternating, then
blink together. Releasing the button now resets the device to its factory settings. The password and
network settings are reset to their default values. Please note that the device name cannot be reset.
yKeeping the button pressed further on, the device proceeds to normal operation. No changes apply.
(C) Short press the Identify button if an error occurs and you want to exit the error mode. The device will
switch back to normal activity if the cause of error is eliminated. The Node might reboot.
(D) e:pix version only: During test mode, single press the Identify button to switch between e:pix and DMX
protocol in the test.
3 General remarks
3.1 Transport
Only transport the device in its original packaging. This protects the device from damage.
3.2 Unpacking
Only unpack the device at its installation location. To protect the device against condensation water, unpack it
and wait until all moisture remaining in the device has evaporated. Condensation can occur when the device is
moved from a cold to a warm location. Keep the packaging for use in case of further transport. Inspect all
parts for completeness regarding chapter “2.1 Delivery content” (page 04). If there is apparent damage to
the device or parts are missing from the delivery scope, please contact the Traxon e:cue support service.