turck FCS-GL1/2A4-NAEX0-H1141/A User manual

Flow monitoring
Immersion sensor without integrated processor
FCS-GL1/2A4-NAEX0-H1141/A
Edition • 2016-02-13T03:12:47+01:00
1 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Type code FCS-GL1/2A4-NAEX0-H1141/A
Ident no. 6870348
Mounting conditions insertion style sensor
Air Operating Range 2…20 m/s
Stand-by time 5…20 s
Temperature jump, response time max. 60 s
Temperature gradient ð 20 K/min
Medium temperature -20…60 °C
Device designation É II 1/2 G EEx ia IIC T6
ignition protection category Ex ia IIC
PowerPið 0.69 W
Internal inductances/capacitances negligibly small
Ex approval acc. to conformity certificate TÜV 99 ATEX 1517X
Protection class IP67
Housing material stainless steel, V4A (1.4571)
Sensor material stainless steel, AISI 316Ti
Max. tightening torque housing nut 30 Nm
Connection flange connector, M12 x 1
Pressure resistance 10 bar
Process connection G ½″ long
■ATEX category II 1/2 G, Ex zone 0
■Intrinsically safe flow sensor for
gaseous media
■Calorimetric principle
■Adjustment via potentiometer located
on the intrinsically safe processor
■Status indicated via LED chain on sig-
nal processor
■Intrinsically safe EEx ia IIC T6, for use
in zone 0
■Plug-in device, M12 x 1
■4-wire connection to an Ex0 processor
Wiring Diagram
Functional principle
Our insertion - flow sensors operate on the
principle of thermodynamics. The measur-
ing probe is heated by several °C as against
the flow medium. When fluid moves along the
probe, the heat generated in the probe is dis-
sipated. The resulting temperature is mea-
sured and compared to the medium tempera-
ture. The flow status of every medium can be
derived from the evaluated temperature differ-
ence. Thus TURCK's wear-free flow sensors
reliably monitor the flow of gaseous and liquid
media.
Flow monitoring
Immersion sensor without integrated processor
FCS-GL1/2A4-NAEX0-H1141/A
Edition • 2016-02-13T03:12:47+01:00
2 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Operating manual
Intended use
This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014, EN50020 and EN50284.
For use in explosion hazardous areas conform to classification
II 1 G (Group II, Category 1 G, electrical equipment for gaseous atmospheres).
Marking (see device or technical data sheet)
É II 1/2 G and EEx ia IIC T6 acc.to EN50020 and EN50284
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
This device is only suited for connection to approved EExi circuits acc. to EN500014 and EN50020. Please observe the maximum admissible
electrical values.
After connection to other circuits the sensor may no longer be used in EExi installations. When interconnected to (associated) electrical equip-
ment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

Other turck Accessories manuals

turck LTX-R10 Series User manual

turck

turck LTX-R10 Series User manual

turck FCS-GL1/2A4-NAEX-H1141 User manual

turck

turck FCS-GL1/2A4-NAEX-H1141 User manual

turck PS Series User manual

turck

turck PS Series User manual

turck 6870375 User manual

turck

turck 6870375 User manual

turck FCS-G NAEX Series User manual

turck

turck FCS-G NAEX Series User manual

turck PS310 Series User manual

turck

turck PS310 Series User manual

turck NI4-DSU35-2Y1X2-H1140 User manual

turck

turck NI4-DSU35-2Y1X2-H1140 User manual

turck RU CK40 Series User manual

turck

turck RU CK40 Series User manual

turck DR Series User manual

turck

turck DR Series User manual

turck NI5-EM12-Y1X-H1141 User manual

turck

turck NI5-EM12-Y1X-H1141 User manual

turck FCS-G1/2HC22-NAEX/D100 5M User manual

turck

turck FCS-G1/2HC22-NAEX/D100 5M User manual

turck FCS-K20-LIX Series User manual

turck

turck FCS-K20-LIX Series User manual

turck BCT-M-IOL Series User manual

turck

turck BCT-M-IOL Series User manual

turck FCS-GL1/2A4-NAEX0 User manual

turck

turck FCS-GL1/2A4-NAEX0 User manual

turck FCS-GL1/2HC22-NAEX-H1141 User manual

turck

turck FCS-GL1/2HC22-NAEX-H1141 User manual

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck PK01VR N Series User manual

turck

turck PK01VR N Series User manual

turck RU40U/3GD Series User manual

turck

turck RU40U/3GD Series User manual

turck FCS-GL1/2A4-NAEX User manual

turck

turck FCS-GL1/2A4-NAEX User manual

turck FCS-G1/2A4-NAEX0-H1141/L065 User manual

turck

turck FCS-G1/2A4-NAEX0-H1141/L065 User manual

turck LPRE-M30-AP6X2-H1141 User manual

turck

turck LPRE-M30-AP6X2-H1141 User manual

turck FS101 Series User manual

turck

turck FS101 Series User manual

turck FCS-DN NAEX0 Series User manual

turck

turck FCS-DN NAEX0 Series User manual

turck LTX Series User manual

turck

turck LTX Series User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.