manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. turck
  6. •
  7. Measuring Instrument
  8. •
  9. turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

Inclinometer
B1N360V-Q20L60-2Li2-H1151/3GD
Edition • 2014-06-17T07:45:37+02:00
1 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Type code B1N360V-Q20L60-2Li2-H1151/3GD
Ident no. 1534113
Measuring range 0…360°
Repeatability ð 0.2 % of measuring range |A - B|
ð 0.1 %, after warm-up 0.5 h
Temperature coefficient typical 0.03 °/K
Resolution ð 0.14 °
Ambient temperature -30…+70 °C
in the explosion hazardous area see instruction
leaflet
Operating voltage 10…30VDC
Rated insulation voltage ð 0.5 kV
Short-circuit protection yes
Wire breakage / Reverse polarity protection yes/ complete
Output function 5-wire, analog output
Current output 4…20mA
2 outputs, one for CW and one for CCW
Load resistance current output ð 0.2 kò
Response time 0.1 s
Time for the output signal to reach 90% of the ad-
justed measuring range
Current consumption 50…105 mA (voltage-dependent)
Approval acc. to ATEX declaration of conformity TURCK Ex-12002H
X
Device designation Ex II 3 G Ex nA IIC T5 Gc/II 3 D Ex tc IIIC T85°C Dc
Design rectangular, Q20L60
Dimensions 60 x 30 x 20 mm
Housing material plastic, PC
Connection male, M12 x 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP68 / IP69K
MTTF 203 years acc. to SN 29500 (Ed.99) 40 °C
Included in scope of supply Security clip SC-M12/3GD
■ATEX category II 3 G, Ex Zone 2
■ATEX category II 3 D, Ex Zone 22
■Rectangular, plastic, PC
■Compact housing
■Connection via M12x1 plug connectors
■12 bit resolution
■5-wire, 10…30 VDC
■4 … 20mA analog output for clockwise
(CW) rotation
■4 … 20mA analog output for counter-
clockwise (CCW) rotation
Wiring diagram
Functional principle
The TURCK inclinometers incorporate a mi-
cromechanical pendulum, operating on the
principle of MEMS technology (Mikro Elektro
Mechanic Systems).
The pendulum basically consists of two 'plate'
electrodes arranged in parallel with a dielec-
tric placed in the middle. When the sensor is
inclined, the dielectric in the middle moves,
causing the capacitance ratio between both
electrodes to change.
The downstream electronics evaluates this
change in capacitance and generates a corre-
sponding output signal.
Inclinometer
B1N360V-Q20L60-2Li2-H1151/3GD
Edition • 2014-06-17T07:45:37+02:00
2 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Mounting instructions / Description Tilt angle
Adjusting the measuring range via TX1-Q20L60 teach
adapter
Setting the angular range in CW direction:
■Move sensor to start position
■Press and hold Teach-Gnd until the output is set to
< 4 mA / 0,1 V (approx. 1 s)
■Move sensor to end position
■Press and hold Teach-Gnd until the output is set to
20 mA / 4.9 V (approx. 3 s)
Resetting the angular range:
■Press and hold Teach-Gnd until the output is set to
12 mA (approx. 6 s)
■The working range of angle measurement is set
back to 360° degrees (in position "connector outgo-
ing topwards" the sensor provides an output signal
in accordance with 0 ° degree)
Inclinometer
B1N360V-Q20L60-2Li2-H1151/3GD
Edition • 2014-06-17T07:45:37+02:00
3 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Accessories
Type code Ident no. Description Dimension drawing
IM43-13-SR 7540041 Limit value monitor; 1-channel; input 0/4…20 mA or 0/2…10
V; supply of 2- or 3-wire transmitters/sensors; limit value ad-
justment via teach button; three relay outputs with one NO
contact each; removable terminal blocks; 27 mm wide; uni-
versal voltage supply 20…250 VUC; further limit value moni-
tors are described in our "Interface Technology" catalog.
TX1-Q20L60 6967114 Teach adapter for inductive encoders, linear position, angle
and ultrasonic sensors
SG-Q20L60 6901100 Protective frame for Q20L60; protects against mechanical im-
pact; stainless steel
Inclinometer
B1N360V-Q20L60-2Li2-H1151/3GD
Edition • 2014-06-17T07:45:37+02:00
4 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Operating manual
Intended use
This device fulfills the directive 94/9/EC and is suited for use in explosion hazardous areas acc. to EN60079-0:2009, EN60079-15:2010 and
EN60079-31:2009.
In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 3 G and II 3 D (Group II, Category 3 G, electrical equipment for gaseous atmospheres and category 3 D, electrical equipment for dust atmo-
spheres).
Marking (see device or technical data sheet)
Ex II 3 G Ex nA IIC T5 Gc acc .to EN 60079-0:2009 and EN 60079-15:2010 and Ex II 3 D Ex tc IIIC T85°C Dc acc. to EN 60079-0:2009 and EN
60079-31:2009
Local admissible ambient temperature
-30…+70 °C
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
Special conditions for safe operation
For devices with M12 connectors please use the supplied safety clip SC-M12/3GD. The safety clips SC-M12/3GD are not required when using
the protective housing SG-Q20L60.
Do not disconnect the plug-in connection or cable when energised.
Please attach a warning label permanently in an appropriate fashion in close proximity to the plug-in connection with the following inscription:
Nicht unter Spannung trennen / Do not separate when energized.
The device must be protected against any kind of mechanical damage and degrading UV-radiation. On selecting the approval-relevant acces-
sories, always ensure that they are installed conform to the application.
Load voltage and operating voltage of this equipment must be provided by power supplies featuring safe isolation (IEC 60 364/ UL 508), which
ensures that the rated voltage (24 VDC +20% = 28.8 VDC) of the equipment is not exceeded by more than 40%.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

Other turck Measuring Instrument manuals

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck B N Series User manual

turck

turck B N Series User manual

turck B N QR20-2UPN Series User manual

turck

turck B N QR20-2UPN Series User manual

turck IMX12-CCM Series User manual

turck

turck IMX12-CCM Series User manual

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck IM34-11Ex-i User manual

turck

turck IM34-11Ex-i User manual

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck MS96-11EX0-R/115VAC User manual

turck

turck MS96-11EX0-R/115VAC User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck IMXK12-AO01 Series User manual

turck

turck IMXK12-AO01 Series User manual

turck FCMI Series User manual

turck

turck FCMI Series User manual

turck BL ident TW-R30-B128-EX User manual

turck

turck BL ident TW-R30-B128-EX User manual

turck FCI-X-H114 Series User manual

turck

turck FCI-X-H114 Series User manual

turck B2N45H-Q20L60-2Li2-H1151/3GD User manual

turck

turck B2N45H-Q20L60-2Li2-H1151/3GD User manual

turck LMA-4 User manual

turck

turck LMA-4 User manual

turck IMX12-CCM02 Series User manual

turck

turck IMX12-CCM02 Series User manual

turck FM-FX/FMX-FX Series User manual

turck

turck FM-FX/FMX-FX Series User manual

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck MK21-122Ex0-R User manual

turck

turck MK21-122Ex0-R User manual

turck FMX-IM-2UPLI63X User manual

turck

turck FMX-IM-2UPLI63X User manual

turck IM18-CCM Series User manual

turck

turck IM18-CCM Series User manual

turck IM18-CCM51-12I User manual

turck

turck IM18-CCM51-12I User manual

turck duotec Latooyete User manual

turck

turck duotec Latooyete User manual

Popular Measuring Instrument manuals by other brands

Simex SUR-W410 user manual

Simex

Simex SUR-W410 user manual

COMECO TC67U Operation manual

COMECO

COMECO TC67U Operation manual

Industrial Scientific Ventis MX4 reference guide

Industrial Scientific

Industrial Scientific Ventis MX4 reference guide

eta 5403 operating instructions

eta

eta 5403 operating instructions

SensorLink True RMS Ampstik 8-020 Operator's manual

SensorLink

SensorLink True RMS Ampstik 8-020 Operator's manual

Brüel & Kjær 2113 Instructions and applications

Brüel & Kjær

Brüel & Kjær 2113 Instructions and applications

RAEWHA IVY LASER SR-830 quick start guide

RAEWHA

RAEWHA IVY LASER SR-830 quick start guide

Fluke VT Plus HF Operator's manual

Fluke

Fluke VT Plus HF Operator's manual

eltherm ELT-GP1 Documentation

eltherm

eltherm ELT-GP1 Documentation

Hyelec MS6508 user manual

Hyelec

Hyelec MS6508 user manual

Digital Projection E-Vision 5100 Series Important information

Digital Projection

Digital Projection E-Vision 5100 Series Important information

PCB Piezotronics IMI SENSORS 646B10 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 646B10 Installation and operating manual

PCB Piezotronics T356A35 Installation and operating manual

PCB Piezotronics

PCB Piezotronics T356A35 Installation and operating manual

Samwon ENG SU-105KRR instruction manual

Samwon ENG

Samwon ENG SU-105KRR instruction manual

T&M TOOLS TL-512 user manual

T&M

T&M TOOLS TL-512 user manual

Clas Ohlson SP-9032B manual

Clas Ohlson

Clas Ohlson SP-9032B manual

AFL VFI2 manual

AFL

AFL VFI2 manual

Ludlum Measurements 2241-3 manual

Ludlum Measurements

Ludlum Measurements 2241-3 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.