manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. turck
  6. •
  7. Measuring Instrument
  8. •
  9. turck MS96-11EX0-R/115VAC User manual

turck MS96-11EX0-R/115VAC User manual

Flow monitoring
MS96 for flow sensors
MS96-11EX0-R/115VAC
Edition • 2015-12-02T05:38:03+01:00
1 / 2 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com
Type code MS96-11EX0-R/115VAC
Ident-No. 5231402
Ident-No (TUSA) M5231402
Ambient temperature -20…60 °C
Operating voltage 99…121 VAC
Current consumption ï 75 mA
Output function Relay output, changover contact
Device designation É II(1) G D [EEx ia] IIC
ignition protection category II(1) G D [EEx ia] II C
Ex approval acc. to conformity certificate TÜV 96 ATEX 1098
IP Rating IP20
Protection class (terminals/housing) IP20 / IP40
Construction terminal chamber
Dimensions 110 x 50 x 75 mm
Housing material polycarbonate/ABS
Connection Terminal chamber
Indication: Drop below setpoint LED red
Indication: Setpoint reached LED yellow
Indication: Setpoint exceeded 4 x LEDs green
■ATEX category II (1) G, Ex Zone 0
■ATEX category II (1) D, Ex Zone 20
■single-channel signal processor MS96
■for connection of an intrinsically safe
flow control sensor in zone 0
■adjustment via potentiometer
■6 LEDs for display of the flow state
■intrinsically safe control circuit, [EExia]
IIC
■switch-off delay adjustable in a range of
0…25 s
■wire-break monitoring
■99…121 VAC
■Changeover contact, relay output
Wiring diagram
Functional principle
Signal processors not only supply insertion
and inline sensors with voltage, they also pro-
cess and display the measured signals. De-
vices with MK96…, MS96… and MC96…
housing styles are available. The individual
housing styles are designed for different oper-
ating voltages and feature various output and
supplementary functions. For intrinsically safe
flow sensors it is required to use signal pro-
cessors with intrinsically safe control circuits
of the series MS96…Ex… and MC96…Ex… .
Flow monitoring
MS96 for flow sensors
MS96-11EX0-R/115VAC
Edition • 2015-12-02T05:38:03+01:00
2 / 2 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com
Operating manual
Intended use
This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014 and EN50020.
In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmo-
spheres).
Marking (see device or technical data sheet)
Ex II 1 G and Ex ia IIC T6 acc. to EN60079-11 and -26 and Ex II 1 D Ex iaD 20 T95°C acc. to EN60079-11 and EN61241-0 and -11
Local admissible ambient temperature
-20…+60 °C
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
This device is accessory equipment which features intrinsically safe circuits as well as non-intrinsically safe circuits. It may only be installed out-
side the explosion hazardous area in dry, clean and well monitored areas. If a declaration of conformity or declaration of the manufacturer as a
category 3 device exists, the device may be installed in zone 2. Special conditions for safe operation must be observed. Intrinsically-safe elec-
trical equipment can be connected to the intrinsically-safe connections. All equipment must comply with the demands for operation in the exist-
ing zone of the explosion hazardous area. If the intrinsically safe circuits lead to the dust explosion hazardous zones 20 or 21, it is important to
ensure that the devices connected to this circuit fulfil the demands for category 1D or 2D and are certified accordingly. If the equipment is inter-
connected, it is necessary to perform the "Proof of intrinsic safety" (EN 60079-14). Equipment which has been used once to connect intrinsical-
ly safe circuits to non-intrinsically safe circuits is no longer suitable for subsequent use with intrinsically safe circuits. Relevant regulations ex-
ist for the establishment of intrinsically-safe circuits, mounting of external connection parts as well as the characteristics and laying of cables.
Cables and terminals with intrinsically-safe circuits must be marked. They should be separated from non-intrinsically safe circuits or must fea-
ture appropriate insulation (EN 60079-14). Observe the prescribed clearances to earthed components and connections of other devices to the
intrinsically-safe connections of this device. Unless expressed specifically in the device-specific operating instructions, the approval becomes
void if the device is opened, repaired or actions are performed on the device by someone other than approved experts or the manufacturer. Vis-
ible changes to the device housing, such as brown-black discolourations caused by heat, as well as holes or bulges also indicate a serious dan-
ger. Switch off the device immediately. With the associated electrical equipment the interconnected intrinsically-safe equipment must also be
checked. Inspection of a device with regard to the explosion protection can only be performed by an expert or the manufacturer. The operation
of the devices is only permitted in conjunction with the permitted data printed on the side of the housing. Before any commissioning or modifica-
tion of the device interconnections, ensure that the respective regulations, directives and conditions have been complied with and also ensure
that use is only for the intended purpose and the safety requirements have been fulfilled.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
Special conditions for safe operation
The device must be protected against any kind of mechanical damage.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

This manual suits for next models

1

Other turck Measuring Instrument manuals

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck IM34-11Ex-i User manual

turck

turck IM34-11Ex-i User manual

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck B2N45H-Q20L60-2Li2-H1151/3GD User manual

turck

turck B2N45H-Q20L60-2Li2-H1151/3GD User manual

turck IM18-CCM51-12I User manual

turck

turck IM18-CCM51-12I User manual

turck MK21-122Ex0-R User manual

turck

turck MK21-122Ex0-R User manual

turck IMXK12-AO01 Series User manual

turck

turck IMXK12-AO01 Series User manual

turck B1N360V-QR20-IOLX3 Series User manual

turck

turck B1N360V-QR20-IOLX3 Series User manual

turck IMX12-CCM Series User manual

turck

turck IMX12-CCM Series User manual

turck IM18-CCM Series User manual

turck

turck IM18-CCM Series User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck FCMI Series User manual

turck

turck FCMI Series User manual

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

turck LMA-4 User manual

turck

turck LMA-4 User manual

turck BL ident TW-R30-B128-EX User manual

turck

turck BL ident TW-R30-B128-EX User manual

turck B N Series User manual

turck

turck B N Series User manual

turck B N -QR20-IOL Series User manual

turck

turck B N -QR20-IOL Series User manual

turck FCI-X-H114 Series User manual

turck

turck FCI-X-H114 Series User manual

turck IMX12-CCM02 Series User manual

turck

turck IMX12-CCM02 Series User manual

turck B N QR20-2UPN Series User manual

turck

turck B N QR20-2UPN Series User manual

turck FMX-IM-2UPLI63X User manual

turck

turck FMX-IM-2UPLI63X User manual

Popular Measuring Instrument manuals by other brands

GEM 3030 mFlow operating instructions

GEM

GEM 3030 mFlow operating instructions

CARLO GAVAZZI EM511 user manual

CARLO GAVAZZI

CARLO GAVAZZI EM511 user manual

Eyedro EBEM1 quick start guide

Eyedro

Eyedro EBEM1 quick start guide

EPI Valumass 400 Series Installation, wiring & configuration

EPI

EPI Valumass 400 Series Installation, wiring & configuration

Fema Electronica M40-D user manual

Fema Electronica

Fema Electronica M40-D user manual

Memsic DMU380ZA Series user manual

Memsic

Memsic DMU380ZA Series user manual

Renesas OB1203SD-BT2-EVK quick start guide

Renesas

Renesas OB1203SD-BT2-EVK quick start guide

Hach sension6 instruction manual

Hach

Hach sension6 instruction manual

Advanced 3320 Service manual

Advanced

Advanced 3320 Service manual

X-Z Lab RadTarge II D700 Operator's manual

X-Z Lab

X-Z Lab RadTarge II D700 Operator's manual

Dawson DAM100B user manual

Dawson

Dawson DAM100B user manual

SDT T-Sonic9 user manual

SDT

SDT T-Sonic9 user manual

MG DLS-C1 instruction manual

MG

MG DLS-C1 instruction manual

KROHNE BW25 Handbook

KROHNE

KROHNE BW25 Handbook

Keysight PD1000A operating guide

Keysight

Keysight PD1000A operating guide

Kobold DRB Series operating instructions

Kobold

Kobold DRB Series operating instructions

Electro-Sensors PM500 user manual

Electro-Sensors

Electro-Sensors PM500 user manual

Mercos DMP 11 instructions

Mercos

Mercos DMP 11 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.