Inclinometer
B2N45H-Q20L60-2Li2-H1151/3GD
Edition • 2016-06-25T05:57:38+02:00
1 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Type code B2N45H-Q20L60-2Li2-H1151/3GD
Ident no. 1534111
Measuring range -45…45°
Measuring range x-axis -45…45°
Measuring range y-axis -45…45°
Repeatability ð 0.2 % of measuring range |A - B|
Linearity deviation ð 0.5 %
Temperature drift ð ± 0.04 % / K
Resolution ð 0.1 °
Ambient temperature -30…+70 °C
in the explosion hazardous area see instruction
leaflet
Operating voltage 10… 30VDC
Rated insulation voltage ð 0.5 kV
Short-circuit protection yes
Wire breakage / Reverse polarity protection yes/ yes
Output function 5-pin, Analog output
Current output 4…20mA
Load resistance, current output ð 0.2 kOhm
Response time 0.1 s
time for the output signal to achieve 90% full scale if
the angle changes from -45° to +45°
Current consumption 50 mA
Approval acc. to ATEX declaration of conformity TURCK Ex-12002H
X
Device designation Ex II 3 G Ex nA IIC T5 Gc/II 3 D Ex tc IIIC T85°C Dc
Construction rectangular, Q20L60
Dimensions 60 x 30 x 20 mm
Housing material Plastic, PC
Connection Flange connector, M12 x 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP68 / IP69K
MTTF 203 years acc. to SN 29500 (Ed. 99) 40 °C
Included in delivery Security clip SC-M12/3GD, SC-M12/3GD
■ATEX category II 3 G, Ex Zone 2
■ATEX category II 3 D, Ex Zone 22
■Plastic, PC
■Zero point calibration +/- 15°
■Two analog outputs
■M12 x 1 male connector
Wiring Diagram
Functional principle
Inclination is determined by a wear-free semi-
conducting sensor element.
Inclinometer
B2N45H-Q20L60-2Li2-H1151/3GD
Edition • 2016-06-25T05:57:38+02:00
2 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Mounting instructions / Description Tilt angle
Inclinometer
B2N45H-Q20L60-2Li2-H1151/3GD
Edition • 2016-06-25T05:57:38+02:00
3 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Accessories
Type code Ident no. Description
VB2-SP3 6999085 Teach adapter
SG-Q20L60 6901100 Protective frame for Q20L60; protects against mechanical im-
pact; stainless steel
IM43-13-SR 7540041 Trip amplifier; 1-channel; input 0/4…20 mA or 0/2…10 V;
supply of 2- or 3-wire transmitters/sensors; limit value adjust-
ment via teach button; three relay outputs with one NO con-
tact each; removable terminal blocks; 27 mm wide; universal
voltage supply 20…250 VUC; further Limit value indicators
are described in our "Interface Technology" catalog.
Inclinometer
B2N45H-Q20L60-2Li2-H1151/3GD
Edition • 2016-06-25T05:57:38+02:00
4 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Operating manual
Intended use
This device fulfills the directive 94/9/EC and is suited for use in explosion hazardous areas acc. to EN60079-0:2009, EN60079-15:2010 and
EN60079-31:2009.
In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 3 G and II 3 D (Group II, Category 3 G, electrical equipment for gaseous atmospheres and category 3 D, electrical equipment for dust atmo-
spheres).
Marking (see device or technical data sheet)
Ex II 3 G Ex nA IIC T5 Gc acc .to EN 60079-0:2009 and EN 60079-15:2010 and Ex II 3 D Ex tc IIIC T85°C Dc acc. to EN 60079-0:2009 and EN
60079-31:2009
Local admissible ambient temperature
-30…+70 °C
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
Special conditions for safe operation
For devices with M12 connectors please use the supplied safety clip SC-M12/3GD. The safety clips SC-M12/3GD are not required when using
the protective housing SG-Q20L60.
Do not disconnect the plug-in connection or cable when energised.
Please attach a warning label permanently in an appropriate fashion in close proximity to the plug-in connection with the following inscription:
Nicht unter Spannung trennen / Do not separate when energized.
The device must be protected against any kind of mechanical damage and degrading UV-radiation. On selecting the approval-relevant acces-
sories, always ensure that they are installed conform to the application.
Load voltage and operating voltage of this equipment must be provided by power supplies featuring safe isolation (IEC 60 364/ UL 508), which
ensures that the rated voltage (24 VDC +20% = 28.8 VDC) of the equipment is not exceeded by more than 40%.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

Other turck Measuring Instrument manuals

turck IMX12-CCM Series User manual

turck

turck IMX12-CCM Series User manual

turck MK21-122Ex0-R User manual

turck

turck MK21-122Ex0-R User manual

turck IM18-CCM51-12I User manual

turck

turck IM18-CCM51-12I User manual

turck FMX-IM-2UPLI63X User manual

turck

turck FMX-IM-2UPLI63X User manual

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck B2NF85H-QR20-IOLX3-H1141 User manual

turck

turck B2NF85H-QR20-IOLX3-H1141 User manual

turck IMXK12-AO01 Series User manual

turck

turck IMXK12-AO01 Series User manual

turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2Li2-H1151/3GD User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck IM18-CCM Series User manual

turck

turck IM18-CCM Series User manual

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck FCI-X-H114 Series User manual

turck

turck FCI-X-H114 Series User manual

turck duotec Latooyete User manual

turck

turck duotec Latooyete User manual

turck FCMI Series User manual

turck

turck FCMI Series User manual

turck IM21-14Ex-CDTRi User manual

turck

turck IM21-14Ex-CDTRi User manual

turck B1N360V-QR20-IOLX3 Series User manual

turck

turck B1N360V-QR20-IOLX3 Series User manual

turck IM34-11Ex-i User manual

turck

turck IM34-11Ex-i User manual

turck FM-FX/FMX-FX Series User manual

turck

turck FM-FX/FMX-FX Series User manual

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck

turck FTCI-3/4D15A4P-2LUX-H1141 User manual

turck IMX12-CCM02 Series User manual

turck

turck IMX12-CCM02 Series User manual

turck B N QR20-2UPN Series User manual

turck

turck B N QR20-2UPN Series User manual

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck

turck B1N360V-Q20L60-2UP6X3-H1151/3GD User manual

turck BL ident TW-R30-B128-EX User manual

turck

turck BL ident TW-R30-B128-EX User manual

Popular Measuring Instrument manuals by other brands

PP Systems CIRAS-3 operating manual

PP Systems

PP Systems CIRAS-3 operating manual

Tektronix TLA7012 instructions

Tektronix

Tektronix TLA7012 instructions

Xylem Sensus PolluTherm F Installation and operating instructions

Xylem

Xylem Sensus PolluTherm F Installation and operating instructions

wtw Multi 197i operating manual

wtw

wtw Multi 197i operating manual

Allendale Electronics AE-MAN-DS user manual

Allendale Electronics

Allendale Electronics AE-MAN-DS user manual

ACR Electronics Vecta 3 Product support manual

ACR Electronics

ACR Electronics Vecta 3 Product support manual

Trotec BP17 operating manual

Trotec

Trotec BP17 operating manual

HEIDENHAIN ND 282 Instruction

HEIDENHAIN

HEIDENHAIN ND 282 Instruction

AmpliVox Otowave 202 operating manual

AmpliVox

AmpliVox Otowave 202 operating manual

M-system AS4M instruction manual

M-system

M-system AS4M instruction manual

Siemens SITRANS F US SONOFLO SONO 3000 instructions

Siemens

Siemens SITRANS F US SONOFLO SONO 3000 instructions

Valeport fastCTD operating manual

Valeport

Valeport fastCTD operating manual

Drawell K960-A operating manual

Drawell

Drawell K960-A operating manual

Guildline 9334A Series Technical manual

Guildline

Guildline 9334A Series Technical manual

THORLABS PDA100A user guide

THORLABS

THORLABS PDA100A user guide

EzCAP ezcap181 manual

EzCAP

EzCAP ezcap181 manual

Supertech agroline Farmpoint instruction manual

Supertech agroline

Supertech agroline Farmpoint instruction manual

PCB Piezotronics IMI SENSORS 622B61 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 622B61 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.