manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tyco Fire Product
  6. •
  7. Irrigation System
  8. •
  9. Tyco Fire Product CENTRAL K25-1 User manual

Tyco Fire Product CENTRAL K25-1 User manual

Other Tyco Fire Product Irrigation System manuals

Tyco Fire Product CENTRAL H-1 User manual

Tyco Fire Product

Tyco Fire Product CENTRAL H-1 User manual

Tyco Fire Product CENTRAL ELO-231 GB User manual

Tyco Fire Product

Tyco Fire Product CENTRAL ELO-231 GB User manual

Tyco Fire Product CENTRAL ELO SW-20 User manual

Tyco Fire Product

Tyco Fire Product CENTRAL ELO SW-20 User manual

Tyco Fire Product Gem G102 User manual

Tyco Fire Product

Tyco Fire Product Gem G102 User manual

Tyco Fire Product CENTRAL TY-B User manual

Tyco Fire Product

Tyco Fire Product CENTRAL TY-B User manual

Tyco Fire Product CENTRAL TY-B Series User manual

Tyco Fire Product

Tyco Fire Product CENTRAL TY-B Series User manual

Tyco Fire Product Omega HEC-12 RES User manual

Tyco Fire Product

Tyco Fire Product Omega HEC-12 RES User manual

Tyco Fire Product central bvr User manual

Tyco Fire Product

Tyco Fire Product central bvr User manual

Tyco Fire Product CENTRAL A User manual

Tyco Fire Product

Tyco Fire Product CENTRAL A User manual

Tyco Fire Product CENTRAL DS-1 User manual

Tyco Fire Product

Tyco Fire Product CENTRAL DS-1 User manual

Tyco Fire Product Star E User manual

Tyco Fire Product

Tyco Fire Product Star E User manual

Tyco Fire Product Star PH-2 User manual

Tyco Fire Product

Tyco Fire Product Star PH-2 User manual

Tyco Fire Product CENTRAL BV-EC User manual

Tyco Fire Product

Tyco Fire Product CENTRAL BV-EC User manual

Tyco Fire Product Star Stealth S112 User manual

Tyco Fire Product

Tyco Fire Product Star Stealth S112 User manual

Tyco Fire Product CENTRAL Omega Prohibitor QR User manual

Tyco Fire Product

Tyco Fire Product CENTRAL Omega Prohibitor QR User manual

Tyco Fire Product Gem F890 User manual

Tyco Fire Product

Tyco Fire Product Gem F890 User manual

Tyco Fire Product CENTRAL ESFR-17 User manual

Tyco Fire Product

Tyco Fire Product CENTRAL ESFR-17 User manual

Tyco Fire Product CENTRAL Royal Flush A User manual

Tyco Fire Product

Tyco Fire Product CENTRAL Royal Flush A User manual

Tyco Fire Product TY-QRF User manual

Tyco Fire Product

Tyco Fire Product TY-QRF User manual

Tyco Fire Product Gem F892 User manual

Tyco Fire Product

Tyco Fire Product Gem F892 User manual

Tyco Fire Product Star E User manual

Tyco Fire Product

Tyco Fire Product Star E User manual

Tyco Fire Product RAPID RESPONSE LFII Series User manual

Tyco Fire Product

Tyco Fire Product RAPID RESPONSE LFII Series User manual

Tyco Fire Product Gem RFII Series User manual

Tyco Fire Product

Tyco Fire Product Gem RFII Series User manual

Tyco Fire Product TY300-FRB User manual

Tyco Fire Product

Tyco Fire Product TY300-FRB User manual

Popular Irrigation System manuals by other brands

Tyco TY-B Series manual

Tyco

Tyco TY-B Series manual

Toro ZSERIES 570Z brochure

Toro

Toro ZSERIES 570Z brochure

OpenSprinkler OSPi user manual

OpenSprinkler

OpenSprinkler OSPi user manual

EINHELL GE-WW 5537 E Original operating instructions

EINHELL

EINHELL GE-WW 5537 E Original operating instructions

Hunter Institutional Series instructions

Hunter

Hunter Institutional Series instructions

Cellfast 52-305 user manual

Cellfast

Cellfast 52-305 user manual

Oral Care Technologies Hydro Floss Instructions for use

Oral Care Technologies

Oral Care Technologies Hydro Floss Instructions for use

Reliable F1-300 quick start guide

Reliable

Reliable F1-300 quick start guide

Irrigation-Mart KIT-GK100-RV-B quick start guide

Irrigation-Mart

Irrigation-Mart KIT-GK100-RV-B quick start guide

Tyco CC3 manual

Tyco

Tyco CC3 manual

Reliable F4FR quick start guide

Reliable

Reliable F4FR quick start guide

Valley Bender160 owner's manual

Valley

Valley Bender160 owner's manual

Reliable F1FR42 Series manual

Reliable

Reliable F1FR42 Series manual

Toro 730 Series Installation and service instructions

Toro

Toro 730 Series Installation and service instructions

Eden 97063-EDAMZ quick start guide

Eden

Eden 97063-EDAMZ quick start guide

Netafim NETBEAT user manual

Netafim

Netafim NETBEAT user manual

Johnson Controls tyco ESFR-17 manual

Johnson Controls

Johnson Controls tyco ESFR-17 manual

Reliable RFC30 LL manual

Reliable

Reliable RFC30 LL manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

General
Description
The Central Model K25-1 Sprinklers
(Ref. Figure 1) are “Early Suppres-
sion Fast Response Sprinklers” hav-
ing a nominal K-factor of 25.2. They
are suppression mode sprinklers,
and their use is especially advanta-
geous as a means of eliminating the
use of in-rack sprinklers, when pro-
tecting high-piled storage.
The Model K25-1 is primarily de-
signed for use with storage heights
of most encapsulated or non-encap-
sulated common materials including
cartoned unexpanded plastics of up
to 40 ft. (12,2 m) and with ceiling
heights of up to 45 ft. (13,7 m). In ad-
dition, the protection of some stor-
age arrangements of roll paper and
rubber tires can be considered as
well.
The K25-1 provides the system de-
signer with hydraulic and sprinkler
placement options not presently
available to the traditional ESFR
sprinklers having a nominal K-Factor
of 14.0. In particular, the Model
K25-1 has been designed to operate
at substantially lower end head pres-
sures, as compared to ESFR sprin-
klers having a nominal K-Factor of
14.0. This feature offers flexibility
when sizing the system piping, as
well as possibly reducing or eliminat-
ing the need for a system fire pump.
Also, the Model K25-1 permits use
of a maximum deflector-to ceiling dis-
tance of 18 inches (460 mm) versus
14 inches (360 mm); and, a storage
arrangement of up to 40 ft. (12,2 m)
with a ceiling height of up to 45 ft.
(13,7 m) does not require in-rack
sprinklers as do ESFR sprinklers
having a nominal K-Factor of 14.0.
The Model K25-1 Pendent Sprinkler
is also Listed by Underwriters Labo-
ratories Inc. (UL) and by UL for use
in Canada (C-UL) as a “Specific Ap-
plication Early Suppression Fast Re-
sponse Sprinkler” as indicated under
the UL and C-UL Specific Applica-
tion Design Criteria section. The spe-
cific application listing provides for
reduced pressure design for the pro-
tection of certain commodities.
Applications for the Model K25-1
Sprinklers are expanding beyond the
current recognized installation stand-
ards. For information regarding re-
search fire tests which may be ac-
ceptable to an Authority Having
Jurisdiction (e.g., flammable liquids,
exposed plastics, and aerosols),
please contact the Technical Serv-
ices Department.
Operation. The fusible link assembly
is comprised of two link halves which
are joined together by a thin layer of
solder. When the rated temperature
is reached, the solder melts and the
two link halves separate, which then
allows the sprinkler to activate and
flow water.
WARNINGS
The Model K25-1 Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the appli-
cable standards of the National Fire
Protection Association, in addition to
the standards of any other authori-
ties having jurisdiction (e.g., Factory
Mutual Research Corporation). Fail-
ure to do so may impair the integrity
of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. The installing contractor or
sprinkler manufacturer should be
contacted relative to any questions.
Early
Suppression
Fast Response
Pendent
Sprinklers
No. 3-1.1
Model K25-1
Early Suppression
Fast Response Sprinklers
Tyco Fire Products — www.centralsprinkler.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446
Customer Services/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385
Technical Services: Tel. (800) 381-9312 / Fax: (800) 791-5500
CENTRAL K25-1 2-01
OBSOLETE
Technical
Data
Sprinkler Identification Number
SIN C9226
Approvals
UL and C-UL Listed.
FM Approved.
(Listings and approvals only apply to
the service conditions indicated in
the Design Criteria section.)
Maximum Working Pressure
175 psi (12,1 bar)
Pipe Thread Connection
1 inch NPT or ISO 7-R1
Discharge Coefficient
K = 25.2 GPM/psi1/2
(362,9 LPM/bar1/2)
Temperature Ratings
165°F/74°C or 214°F/101°C
Finish
Natural Brass
Physical Characteristics
The Model K25-1 utilizes a dezincifi-
cation resistant bronze alloy frame.
The strut and hook are monel; and,
the button, deflector, and compres-
sion screw are bronze. The frame ori-
fice is sealed with a gasketed spring
plate (Belleville Seal) consisting of a
beryllium nickel disc spring that is
sealed on both its inside and outside
edges with a Teflon

gasket, and the
two halves of the fusible link assem-
bly are nickel.
Design
Criteria
ULandC-ULListingCriteria
The Model K25-1 Sprinklers are UL
andC-ULListedas“EarlySuppres-
sion Fast Response Sprinklers” for
installation per NFPA 13 or other ap-
plicable NFPA standards.
UL and C-UL Specific
Application Listing Criteria
The Model K25-1 Sprinklers are UL
and C-UL Listed as “Specific Applica-
tion Early Suppression Fast Re-
sponse Sprinklers” for use in in ac-
cordance with NFPA 13 to protect
single-, double-, and multiple row
rack storage and palletized and solid
pile storage (no open containers or
solid shelves) of Class I, II, III, and
IV commodities encapsulated or un-
encapsulated and cartoned Group A
unexpanded plastics when installed
with the following storage and ceiling
heights and minimum design pres-
sures:
Maximum Maximum Minimum
Storage Ceiling Flowing
Height, Height, Pressure,
Ft.(m) Ft.(m) psi(bar)
40 (12,2) 45 (13,7) 40 (2,7)
35 (10,7) 40 (12,2) 25 (1,7)
30 (9,1) 35 (10,7) 20 (1,4)
25 (7,6) 30 (9,1) 15 (1,0)
When applying the specific applica-
tion listing criteria, the Model K25-1
Sprinklers should be installed using
the same installation obstruction and
construction criteria, as well as de-
flector-to ceiling distances, as is ap-
plicable for Early Suppression Fast
Response Sprinklers having a nomi-
nal K-Factor of 25.2 per NFPA 13.
FM Approval Criteria
The Model K25-1 Sprinklers are FM
Approved as “Early Suppression
Fast Response Sprinklers” for instal-
lation per the applicable FM Loss
Prevention Data Sheets.
Figure 1
Model K25-1 ESFR Pendent Sprinkler
1" NPT
(BOTH SIDES)
WRENCH FLAT
(96.8 mm)
3-13/16"
9/16" (14.3 mm)
NOMINAL MAKE-IN
2" (50.8 mm)
TEMPERATURE
RATING
ASSEMBLY
LINK
HOOK
†
Dupont Registered Trademark
OBSOLETE
Installation
The Model K25-1 Pendent Sprinklers
are to be installed in accordance
with the following instructions:
NOTE
Damage to the fusible Link Assem-
bly during installation can be
avoided by handling the sprinkler by
the frame arms only (i.e., do not ap-
plypressuretothefusibleLinkAs-
sembly), and by using the appropri-
ate sprinkler wrench. Damaged
sprinklers must be replaced.
A leak tight 1 inch NPT sprinkler
joint should be obtained with a
torque of 20 to 30 ft.lbs. (26,8 to
40,2 Nm). Higher levels of torque
may distort the sprinkler inlet with
consequent leakage or impairment
of the sprinkler.
Step 1. The K25-1 Sprinkler must be
installed in the pendent position.
Step 2. With pipe thread sealant ap-
plied, hand tighten the sprinkler into
the sprinkler fitting. Do not apply
pressure to the Link Assembly, and
handle the K25-1 Sprinkler only by
the Frame arms.
Step 3. Wrench tighten the K25-1
Sprinkler using only the W-Type 1
Sprinkler Wrench (Ref. Figure 2) and
by fully engaging (seating) the
wrench with the sprinkler wrench
flats.
Step 4. After installation, inspect the
Link Assembly of each K25-1 Sprin-
kler for damage. In particular, verify
that the Link Assembly and Hook are
positioned as illustrated in Figure 1,
and that the Link Assembly has not
been bent, creased, or forced out of
its normal position in any way.
Damaged sprinklers must be re-
placed.
Care &
Maintenance
The Model K25-1 must be main-
tained and serviced in accordance
with the following instructions:
NOTE
Before closing a fire protection sys-
tem main control valve for mainte-
nance work on the fire protection sys-
tem which it controls, permission to
shut down the affected fire protec-
tion systems must be obtained from
the proper authorities and all person-
nel who may be affected by this ac-
tion must be notified.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
shipped or stored where their tem-
perature will exceed 100°F/38°C and
they must never be painted, plated,
coated, or otherwise altered after
leaving the factory. Modified or over-
heated sprinklers must be replaced.
Care must be exercised to avoid
damage - before, during, and after
installation. Sprinklers damaged by
dropping, striking, wrench twist/slip-
page, or the like, must be replaced.
The owner is responsible for the in-
spection, testing, and maintainance
of their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any
other authorities having jurisdiction.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under nor-
mal use and service. This warranty
will expire ten (10) years from date
of shipment by Tyco Fire Products.
No warranty is given for products or
components manufactured by com-
panies not affiliated by ownership
with Tyco Fire Products or for prod-
ucts and components which have
been subject to misuse, improper in-
stallation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with
applicable Standards of the National
Fire Protection Association, and/or
the standards of any other Authori-
ties Having Jurisdiction. Materials
found by Tyco Fire Products to be de-
fective shall be either repaired or re-
placed, at Tyco Fire Products’ sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products
or parts of products. Tyco Fire Prod-
ucts shall not be responsible for
sprinkler system design errors or in-
accurate or incomplete information
supplied by Buyer or Buyer’s repre-
sentatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY
OR UNDER ANY OTHER LEGAL
THEORY, FOR INCIDENTAL, INDI-
RECT, SPECIAL OR CONSEQUEN-
TIAL DAMAGES, INCLUDING BUT
NOT LIMITED TO LABOR
CHARGES, REGARDLESS OF
WHETHER TYCO FIRE PRODUCTS
WAS INFORMED ABOUT THE POS-
SIBILITY OF SUCH DAMAGES,
ANDINNOEVENTSHALLTYCO
FIRE PRODUCTS’ LIABILITY EX-
CEED AN AMOUNT EQUAL TO THE
SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHER WARRANTIES EXPRESS
OR IMPLIED, INCLUDING WAR-
RANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICU-
LAR PURPOSE.
"FITTING SIDE"
FITTING
TOWARDS SPRINKLER
RECESS
WRENCH
Figure 2
W-Type 1
Sprinkler Wrench
OBSOLETE
Ordering
Information
Ordering Information: When plac-
ing an order, indicate the full product
name. Please specify the quantity,
model, style, and size, as applicable.
Refer to Price List for complete list-
ing of Part Numbers.
Patents:
U.S.A. Patent Numbers 4,580,729,
5,829,532, and 6,059,044 are appli-
cable to the Model K25-1. Other pat-
ents are pending.
Printed in U.S.A. 2-01