连接 接 口
Specification
4
10/100/1000M Unmanaged Switch 4口百兆以太网交换机
3
Product parameters are project to change without prior notice.
ITEM
PCB
PCBA Solder Joint
Components
Metal Hardware
Plastic Hardware
Paper Accessories
Glass
CD
Cable
PBB PBDE
Hazardous Substance
This table is made base on G B/ T 26572 standard.
Indicates that the con ce nt ra ti on o f th e hazardous substance in all homogeneous
materials in the part is b el ow t he r el ev ant threshold of the GB/T 26572 standard.
Indicates that the con ce nt ra ti on o f th e hazardous substance in all homogeneous
materials in the part is a bo ve t he r el ev ant threshold of the GB/T 26572 standard.(Ho we ve r,
this project only has a sm al l nu mb er o f ap plications in the inventory or processed products,
and according to the p la n, t he e nv ir on mental protection switch is being carried out, which
will meet the above requ ir em en ts
The ter m of this e nviro nme ntal
prote ction only applies to the
pr od uct wo rk in g und er th e
co nd it ions sp ecified i n t he
user ma nual
RJ 45 Making Method
pin color
white/green
green
blue
white/orange
white/blue
white/brown
orange
brown
1
2
3
4
5
6
7
8
pin color
1
2
3
4
5
6
7
8
white/green
green
blue
white/orange
white/blue
white/brown
orange
brown
EIA/TIA 568A EIA/TIA 568B
Notice
When choose RJ-45 make sure if one end is EIA/TIA568A,the other end should also be EIA/TIA568A.
When choose RJ-45 make sure if one end is EIA/TIA568B,the other end should also be EIA/TIA568B.
Instruments to be used: wire crimper, network tester. Wire sequence of RJ45 plug should conform with
EIA/TIA568A or 568B.
1) Shuck off about 2cm long the insulating layer, and bar the 4 pairs UTP cable;
2) Depart the 4 pairs UTP cable and straighten them;
3) Line up the 8 pieces of cables per EIA/TIA 568A or 568B;
4) Cut out 1.5 cm cable wrap and leave the bare wire;
) Plug 8 cables into RJ45 plug, make sure each cable is in each pin;
5
6) Then use wire crimper to crimp it;
7) Follow the 5 steps above to make the another end, following the same sequence of the first plug;
8) Using network tester to test the cable whether is working.
Link/Act Indicator per port, 1*Power Indicator
Link/Act: Connecting (ON), Data transmitting(BLINK), Linkage fault(OFF)
Power(PWR): Supply power (ON), Power supply failure (OFF)
Contact discharge 6KV, air discharge 8KV
Input: 100V~240V AC,50/60Hz
1. De fault: All ports could be communicated freel y.
2. VL AN: Port 1 -3/6 are isolated, but can be
communicated with the last tw o ports.
3. CC TV: Port 1 - 4/8: 100Mbps, 160 meters.
10/100/1000M Unmanaged Switch
-10℃~+50℃
-40℃~+85℃