V-TAC iMars XG100KTR User manual

Preface
The
manual
is
intended
to
provide
detailed
information
of
product
information
,
installation
,
application
,
trouble
shooting
,
precautions
and
maintenance
of
iMars
series
grid
-
tied
solar
inverters
.
The
manual
does
not
contain
all
the
information
of
the
photovoltaic
system
.
Please
read
this
manual
carefully
and
follow
all
safety
precautions
seriously
before
any
moving
,
installation
,
operation
and
maintenance
to
ensure
correct
use
and
high
performance
of
operation
on
the
inverter
.
The
use
of
the
iMars
series
grid
-
tied
solar
inverters
must
comply
with
local
laws
and
regulations
on
grid
-
tied
power
generation
.
The
manual
needs
to
be
kept
well
and
be
available
at
all
times
.
All
rights
reserved
.
The
contents
in
this
document
are
subject
to
change
without
notice
.
There
may
be
data
deviation
because
of
product
improving
.
Detailed
information
is
in
accordant
with
the
final
product
.

Three
-
phase
photovoltaic
grid
-
connected
inverter
Content
Preface
.
i
Content
ii
1
Safety
precautions
.
1.1
Warning
marks
.
1
1
1.2
Safety
guidance
1
1.2
.
1
Transport
and
installation
1.2
.
2
Grid
-
connected
operation
....
1.2
.
3
Maintenance
and
inspection
.
3
.
3
.
4
1.2
.
4
Waste
disposal
.
4
2
Product
overview
.
,
5
2.1
PV
grid
-
connected
power
generation
system
2.1
.
1
Supported
grid
connection
structure
2.2
Appearance
of
inverter
.
5
.
5
.
6
2.3
Nameplate
.
8
2.4
Product
model
.
9
2.5
Outline
dimension
and
weight
.
9
2.6
The
LED
light
panel
2.6
.
1
The
modern
model
of
the
LED
panel
2.6
.
2
Classic
LED
light
panel
11
11
12
2.7
Bottom
of
chassis
13
3
Storage
.
14
4
Installation
15
4.1
Unpacking
confirmation
4.2
Preparation
before
installation
16
16
4.2
.
1
Installation
tool
16
4.2
.
2
Installation
environment
17
4.3
Space
requirements
4.4
The
size
of
installation
hanging
board
4.5
Bracket
installation
18
19
.
20
4.6
Wall
installation
.
21
4.7
Installation
of
inverter
.
.
22
ii
www.led-italia.it

Contents
Three
-
phase
photovoltaic
grid
-
connected
inverter
5
Electrical
connection
.
23
5.1
Overview
of
electrical
connection
.
23
5.2
Connect
the
protective
earth
wire
5.3
Connection
of
photovoltaic
string
5.4
Three
-
phase
inverter
grid
connection
5.4
.
1
Terminal
block
grid
connection
5.4
.
2
Parallel
connection
requirements
of
multiple
inverters
.
23
.
24
26
.
26
.
27
5.5
Connect
the
communication
line
.
28
5.5
.
1
Interface
description
.
28
6
Running
6.1
Inspection
before
running
6.2
Inverter
grid
-
connected
running
...
6.3
Inverter
stop
6.4
Daily
maintenance
and
inspection
.
29
.
29
.
29
,
30
.
30
6.4
.
1
Periodic
maintenance
on
the
inverter
.
31
6.4
.
2
Maintenance
guidance
32
7
Fault
isolation
.
34
8
Contact
us
.
38
9
Appendix
.
39
iii

Safety
precautions
Three
-
phase
photovoltaic
grid
-
connected
inverter
1
Safety
precautions
iMars
series
grid
-
tied
solar
inverters
are
designed
and
tested
strictly
in
accordance
with
relevant
international
safety
standards
.
As
an
electrical
and
electronic
device
,
all
relevant
safety
regulations
must
be
strictly
complied
during
installation
,
operation
,
and
maintenance
.
Incorrect
use
or
misuse
may
result
in
:
•
Injury
to
the
life
and
personal
safety
of
the
operator
or
other
people
.
•
Damage
to
the
inverter
or
other
property
belonging
to
the
operator
or
other
people
.
In
order
to
avoid
personal
injury
,
damage
to
the
inverter
or
other
devices
,
please
strictly
observe
the
following
safety
precautions
.
This
chapter
mainly
describes
various
warning
symbols
in
operation
manual
and
provides
safety
instructions
for
the
installation
,
operation
,
maintenance
and
use
of
the
iMars
series
grid
-
tied
solar
inverters
.
1.1
Warning
marks
Warning
marks
inform
users
of
conditions
which
can
cause
serious
physical
injury
or
death
,
or
damage
to
the
device
.
They
also
tell
users
how
to
prevent
the
dangers
.
The
warning
marks
used
in
this
operation
manual
are
shown
below
:
Mark
Name
Instruction
Abbreviation
A
Serious
physical
injury
or
even
death
may
occur
if
not
follow
relevant
requirements
.
Danger
Danger
A
Physical
injury
or
damage
to
the
device
may
occur
if
not
follow
relevant
requirements
.
Warning
Warning
A
Damage
may
occur
if
relevant
requirements
are
not
followed
.
Electrostatic
Forbid
sensitive
A
A
Do
not
touch
the
base
of
the
inverter
as
it
will
High
temperature
Hot
become
hot
.
The
procedures
taken
for
ensuring
proper
operation
.
Note Note
Note
1

Safety
precautions
Three
-
phase
photovoltaic
grid
-
connected
inverter
1.2
Safety
guidance
•
After
receiving
this
product
,
first
confirm
the
product
package
is
intact
.
If
any
question
,
contact
the
logistic
company
or
local
distributor
immediately
.
•
The
installation
and
operation
of
PV
inverter
must
be
carried
out
by
professional
technicians
who
have
received
professional
trainings
and
thoroughly
familiar
with
all
the
contents
in
this
manual
and
the
safety
requirements
of
the
electrical
system
.
•
Do
not
carry
out
connection
/
disconnection
,
unpacking
inspection
and
unit
replacement
operations
on
the
inverter
when
power
source
is
applied
.
Before
wiring
and
inspection
,
users
must
confirm
the
breakers
on
DC
and
AC
side
are
disconnected
and
wait
for
at
least
5
minutes
.
•
Ensure
there
is
no
strong
electromagnetic
interference
caused
by
other
electronic
or
electrical
devices
around
the
installation
site
.
•
Do
not
refit
the
inverter
unless
authorized
.
A
•
All
the
electrical
installation
must
conform
to
local
and
national
electrical
standards
.
A
•
Do
not
touch
the
housing
of
the
inverter
or
the
radiator
to
avoid
scald
as
they
may
become
hot
during
operation
A
•
Ground
with
proper
technics
before
operation
.
•
Do
not
open
the
surface
cover
of
the
inverter
unless
authorized
.
The
electronic
components
inside
the
inverter
are
electrostatic
sensitive
.
Do
take
proper
anti
-
electrostatic
measures
during
authorized
operation
.
©
•
The
inverter
must
be
reliably
grounded
.
e
•
Ensure
that
DC
and
AC
side
circuit
breakers
have
been
disconnected
and
wait
at
5
min
least
5
minutes
before
wiring
and
checking
.
Note
:
Technical
personnel
who
can
perform
installation
,
wiring
,
commissioning
,
maintenance
,
troubleshooting
and
replacement
of
the
iMars
series
grid
-
tied
solar
inverters
must
meet
the
following
requirements
:
•
Operators
need
professional
training
.
•
Operators
must
read
this
manual
completely
and
master
the
related
safety
precautions
.
•
Operators
need
to
be
familiar
with
the
relevant
safety
regulations
for
electrical
systems
.
2

Safety
precautions
Three
-
phase
photovoltaic
grid
-
connected
inverter
•
Operators
need
to
be
fully
familiar
with
the
composition
and
operating
principle
of
the
entire
grid
-
tied
photovoltaic
power
generation
system
and
related
standards
of
the
countries
/
regions
in
which
the
project
is
located
.
Operators
must
wear
personal
protective
equipment
.
1.2
.
1
Transport
and
installation
•
During
storage
or
transport
,
ensure
the
inverter
package
and
the
chassis
is
intact
,
dry
and
clean
.
•
The
movement
and
installation
of
the
inverter
require
at
least
two
persons
due
to
its
heavy
weight
.
•
Select
proper
tools
for
movement
and
installation
to
ensure
the
inverter
can
operate
normally
and
avoid
physical
injury
.
The
installation
personnel
must
take
mechanical
protective
measures
such
as
wearing
anti
-
drop
shoes
or
working
clothes
to
protect
physical
security
.
•
The
inverter
must
be
installed
by
professional
technicians
.
•
Do
not
store
or
install
the
inverter
on
flammable
and
combustible
objects
;
keep
the
inverter
away
from
flammable
and
combustible
objects
.
•
Do
not
install
the
inverter
in
places
easily
accessible
to
children
or
other
public
.
•
Remove
the
metal
accessories
in
hands
eg
ring
or
bracelet
before
device
installation
and
electrical
connection
to
avoid
electric
shock
.
•
The
solar
battery
component
exposed
to
the
sunlight
may
generate
dangerous
voltage
.
Users
must
cover
the
battery
component
with
fully
-
lightproof
materials
before
electrical
connection
•
The
inverter
input
voltage
cannot
exceed
the
max
input
voltage
,
otherwise
the
inverter
may
be
damaged
.
•
PV
grid
-
connected
inverter
is
not
applicable
to
the
positive
or
negative
ground
system
of
solar
battery
component
.
•
Ensure
inverter
PE
is
grounded
properly
,
otherwise
the
inverter
cannot
run
normally
.
•
Ensure
the
inverter
is
installed
firmly
and
electrical
wiring
is
reliable
.
Note
:
PV
grid
-
connected
inverter
is
only
suitable
for
crystalline
silicon
-
type
solar
battery
component
.
1.2
.
2
Grid
-
connected
operation
•
Permissions
by
local
electric
power
agency
must
be
obtained
and
the
inverter
grid
-
connected
power
generation
operation
must
be
done
by
professional
technicians
.
3

Safety
precautions
Three
-
phase
photovoltaic
grid
-
connected
inverter
•
All
electrical
connections
must
meet
the
electrical
standards
of
the
countries
/
regions
in
which
the
project
is
located
.
•
Ensure
the
inverter
is
installed
firmly
and
electrical
wiring
is
reliable
before
operating
on
the
inverter
.
•
Do
not
open
the
housing
of
the
inverter
when
the
inverter
is
working
or
powered
up
.
1.2
.
3
Maintenance
and
inspection
•
The
maintenance
,
inspection
and
repair
of
the
inverter
must
be
done
by
well
trained
and
qualified
professional
technicians
.
•
Contact
distributors
and
manufactures
for
repair
of
the
inverter
.
•
In
order
to
avoid
irrelevant
personnel
from
entering
the
maintenance
area
during
maintenance
,
temporary
warning
labels
must
be
placed
to
warn
non
-
professionals
to
enter
or
use
fence
for
isolation
.
•
Before
carrying
out
any
maintenance
operations
,
users
must
disconnect
the
breaker
on
grid
side
,
then
disconnect
the
breaker
connected
to
the
PV
component
and
wait
for
at
least
5
minutes
until
the
internal
parts
of
the
inverter
are
fully
discharged
.
•
The
internal
of
the
inverter
are
mostly
electrostatic
-
sensitive
circuits
and
parts
,
users
must
follow
electrostatic
protection
protocols
and
take
anti
-
electrostatic
measures
.
•
Do
not
use
components
provided
by
other
companies
when
repairing
the
inverter
.
•
The
inverter
can
be
started
again
for
grid
-
connected
power
generation
only
after
confirming
there
is
no
fault
that
may
impact
the
safety
performance
of
the
inverter
.
•
Do
not
get
close
to
or
touch
the
grid
or
any
metal
conductive
parts
in
the
PV
power
generation
system
during
operation
,
otherwise
electric
shock
or
fire
may
occur
.
Take
note
of
any
safety
marks
and
instructions
similar
to
“
Danger
,
electric
shock
risk
"
.
1.2
.
4
Waste
disposal
•
Do
not
dispose
of
the
inverter
together
with
household
waste
.
The
user
has
the
responsibility
and
obligation
to
send
it
to
the
designated
organization
for
recycling
and
disposal
.
4

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
2
Product
overview
This
chapter
mainly
describes
the
appearance
,
package
accessories
,
nameplate
and
technical
parameters
of
the
grid
-
connected
inverter
.
2.1
PV
grid
-
connected
power
generation
system
PV
grid
-
connected
power
generation
system
is
comprised
of
solar
battery
component
,
grid
-
connected
inverter
,
power
energy
gauging
device
and
public
grid
.
Grid
-
tied
Solar
Inverter
Public
Grid
Solar
PV
Modules
Feeding
Meter
DEE
DDD
DIHDIHDD
i
‘
m
Fig
2.1
Application
of
PV
grid
-
connected
inverter
The
PV
grid
-
connected
inverter
is
the
core
part
of
solar
PV
grid
-
connected
power
generation
system
.
The
sunlight
can
be
converted
to
DC
energy
through
PV
component
,
then
it
is
converted
to
the
sine
AC
current
which
has
the
same
frequency
and
phase
position
with
the
public
grid
via
photovoltaic
grid
-
connected
inverter
,
and
feedback
such
energy
to
the
grid
.
•
It
is
recommended
that
the
PV
array
to
be
installed
conforms
to
IEC
61730
class
A
standards
.
2.1
.
1
Supported
grid
connection
structure
iMars
series
grid
-
tied
solar
inverters
support
TN
-
S
,
TN
-
C
,
TN
-
C
-
S
,
TT
and
IT
grid
connection
.
When
applied
to
the
TT
connection
,the
N
-
to
-
PE
voltage
should
be
less
than
30
V
.
5

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
TN
-
S
TN
-
C
TN
-
C
-
S
Transformer
Transformer
Transformer
L
1
L
1
L
1
L
2
L
2
L
2
L
3
L
3
L
3
N
PEN
N
PE PE
v
/
PE PE PE
Solar
Inverter
Solar
Inverter
Solar
Inverter
TT
IT
Transformer
Transformer
L
1
L
1
s
L
2
L
2
L
3
L
3
N
v
'
r
i
PE
Solar
Inverter
Solar
Inverter
Fig
2.2
Type
of
grid
2.2
Appearance
of
inverter
2
3
4
[
Sl
3
£
ì
g
3
)
£
3
^
sirafasiira
®
o
è
®
o
o
(
!
)
5
iiwt
X
ff
>
m
o
GP
5
»
:
“
m
&
J
1
I
1
i
11
i
11
1
w
.
»
>
Fig
2.3
Appearance
of
three
-
phase
PV
inverter
6

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
Table
2
-
1
Instruction
for
key
cosmetic
parts
of
three
-
phase
PV
inverter
No
Name
xplain
DC
switch
Switch
on
or
switch
off
DC
input
1
DC
input
interface
Inverter
DC
input
port
,
connect
to
PV
array
2
Communication
interface
RS
485
communication
interface
and
its
extension
port
EXT
3
AC
terminal
Inverter
AC
output
port
,
connect
to
public
grid
4
5
LED
light
Instructions
inverter
current
working
condition
6
Hanging
ear
Install
the
inverter
in
the
flip
chart
Nameplate
Indicate
the
rated
inverter
parameters
7
A
total
of
two
,
choose
at
least
one
connection
8
Earthing
terminal
9
Base
of
the
handle
Around
two
,
used
for
handling
inverter
7

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
2.3
Nameplate
Figure
2.4
shows
the
inverter
nameplate
.
}
Grid
-
tied
Solar
Inverter
invt
1
iMars
XG
100
KTR
DC
Input
lioov
Vmax
.
PV
MPPT
Range
180
V
-
1000
V
Max
.
Current
26
AX
9
IscPV
40
AX
9
AC
Output
Nominal
Voltage
3
/
N
/
PE
.
230
/
400
V
Max
.
Current
158.8
A
2
Rated
Power
100000
W
Max
.
Apparent
Power
lioooow
Frequency
50
Hz
/
60
Hz
Power
factor
range
0.80
un
-
0.80
ov
Environment
Temperature
-
30
°
C
~
+
60
°
C
I
Protective
Class
Inverter
topology
Non
-
isolated
Ingress
protection
IP
66
A
£
@
C
S
>
3
Made
in
China
INVT
Solar
Technology
(
Shenzhen
)
Co
.
,
Ltd
.
Fig
2.4
Inverter
nameplate
(
1
)
Trademark
and
product
type
(
2
)
Model
and
important
technical
parameters
(
3
)
Certification
system
of
the
inverter
confirming
,
serial
number
,
company
name
and
country
of
origin
8

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
Icons
Instruction
•
TUV
certification
mark
.
The
inverter
is
certified
by
TUV
.
C
•
CE
certification
mark
.
The
inverter
complies
with
the
CE
directive
.
•
CQC
certification
mark
.
The
inverter
passed
CQC
certification
.
•
EU
WEEE
mark
.
The
inverter
cannot
be
disposed
of
as
domestic
waste
.
2.4
Product
model
Table
2
-
2
Models
of
three
-
phase
PV
grid
-
connected
inverter
Product
name
Model
Rated
output
power
(
W
)
three
-
phase
(
L
1
,
L
2
,
L
3
,
N
,
PE
)
three
-
phase
photovoltaic
grid
-
connected
inverter
XG
100
KTR
100
three
-
phase
photovoltaic
grid
-
connected
inverter
XG
110
KTR
110
three
-
phase
photovoltaic
grid
-
connected
inverter
XG
110
KTR
-
L
110
three
-
phase
photovoltaic
grid
-
connected
inverter
XG
136
KTR
-
X
136
Note
:
Technical
parameters
of
iMars
series
inverter
refers
to
appendix
2.5
Outline
dimension
and
weight
D
W
i
invt
H
x
\
?
U
BUI
til
n
a
mimili
TT
I
Fig
2.5
Outline
dimension
and
weight
of
the
inverter
9

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
Table
2
-
3
Dimension
and
net
weight
of
the
inverter
Height
(
mm
)
Width
(
mm
)
Depth
(
mm
)
Net
weight
(
kg
)
Model
100
kW
660
1050
330
95
110
kW
660
1050
330
98
136
kW
660
1050
330
101
Fig
2.6
Dimension
of
paper
package
Table
2
-
4
Package
dimension
and
gross
weight
Height
(
mm
)
Width
Depth
(
mm
)
Weight
Package
material
Model
(
mm
)
(
kg
)
830
1260
585
120
Pallet
+
cartons
100
kW
830
1260
585
123
Pallet
+
cartons
110
kW
830
1260
585
126
Pallet
+
cartons
136
kW
10

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
2.6
The
LED
light
panel
The
LED
indicator
panel
as
the
human
-
computer
interaction
interface
,
may
indicate
the
working
state
of
the
inverter
.
2.6
.
1
The
modern
model
of
the
LED
panel
«
invt
X
?
Wl
!
®
sminili
;
'
®
'
a
0 0
LED
indicator
light
state
description
;
Normal
grid
-
connected
power
generation
Blue
light
is
ON
Dc
or
ac
has
electricity
,
inverter
was
in
a
state
of
standby
or
start
(
Not
Grid
-
connected
)
Blue
light
flashing
periodically
Blue
light
is
ON
Inverter
not
connected
to
grid
Have
a
failure
.
(
The
inverter
can
not
be
connected
to
the
grid
)
Redlight
is
ON
Red
light
flashing
slowly
(
Is
ON
,
4
s
OFF
)
Inverter
in
alarm
state
Red
lightflashingquickly
(
0.5
s
ON
,
0.5
s
OFF
)
Inverterin
maintenance
state
11

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
2.6
.
2
Classic
LED
light
panel
5
:::
W
1
i
.
®
TmmrnF
®
LED
indicator
definition
:
©
®
© ©
11
)
PV
connection
indicator
(
2
)
Grid
-
connected
indicator
<
3
)
Communication
indicator
©
© ©
©
-
{
>
~
M
A
(
4
)
Warning
indicator
LED
indicator
light
state
description
:
pilot
lamp
State
Meaning
At
least
one
of
the
PV
strings
is
connected
normally
,
and
the
DC
input
voltage
of
the
corresponding
MPPT
circuit
is
greater
than
or
equal
to
200
V
Green
light
is
ON
PV
connection
indicator
=
The
inverter
is
disconnected
from
all
PV
Green
light
is
OFF
strings
,
or
the
DC
input
voltage
of
all
MPPT
circuits
is
less
than
200
V
.
Grid
-
connected
Green
light
is
ON
Inverter
connected
to
grid
indicator
Green
light
is
OFF
Inverter
not
connected
to
grid
Green
light
flashing
(
0.2
s
ON
,
0.2
s
OFF
)
The
inverter
receives
the
digital
converter
through
RS
485
/
PLC
communication
.
Communication
12

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
State
pilot
lamp
Meaning
indicator
The
inverter
does
not
receive
data
Green
light
is
OFF
through
RS
485
/
PLC
communication
for
10
s
.
Red
light
flashing
slowly
(
1
s
ON
,
4
s
OFF
)
The
inverter
gives
an
alarm
Warning
indicator
Alarm
Red
light
flashingquickly
(
0.5
s
ON
,
0.5
s
OFF
)
status
The
inverter
has
a
secondary
alarm
Red
light
is
ON
The
inverter
has
an
important
alarm
2.7
Bottom
of
chassis
XG
100
-
110
KTR
is
equipped
with
three
DC
switches
,
and
XG
136
KTR
is
equipped
with
four
DC
switches
.
Each
DC
switch
controls
the
DC
terminal
corresponding
to
its
area
.
.
rr
3
% %
®
T
#
i
l
®
i
*
J
» »
!
»
-
»
]
[
»
-
»
J
l
'
#
”
V
'
•
"
"
•
i
arm
-
»
,
S
i
©
©
(
g
)
®
o o
3
J
7
7
XG
100
-
110
KTRbottom
view
-
k
k
gglgglglgl
k
©
i
:
s
©
©
E
a
,
j
7
XG
136
KTRbottom
view
13

Three
-
phase
photovoltaic
grid
-
connected
inverter
Storage
3
Storage
If
the
inverter
is
not
put
into
use
immediately
,
the
storage
of
inverter
should
meet
the
following
requirements
:
•
Do
not
remove
the
outer
packing
.
•
The
inverter
needs
to
be
stored
in
a
clean
and
dry
place
,
and
prevent
the
erosion
of
dust
and
water
vapor
.
•
The
storage
temperature
should
be
kept
at
-
40
°
C
~
+
70
°
C
,
and
the
relative
humidity
should
be
kept
at
5
%
RH
~
95
%
RH
.
•
The
stacking
of
inverters
is
recommended
to
be
placed
according
to
the
number
of
stacking
layers
in
the
original
shipment
.
Place
the
inverter
carefully
during
stacking
to
avoid
personal
injury
or
equipment
damage
caused
by
the
falling
of
equipment
.
•
Keep
away
from
chemically
corrosive
substances
that
may
corrode
the
inverter
.
•
Periodic
inspections
are
required
.
If
damages
are
found
by
worms
and
rats
,
or
packaging
are
found
to
be
damaged
,
the
packaging
materials
must
be
replaced
in
time
.
•
After
long
-
term
storage
,
inverters
need
to
be
inspected
and
tested
by
qualified
personnel
before
put
into
use
.
14

Three
-
phase
photovoltaic
grid
-
connected
inverter
Installation
4
Installation
This
chapter
describes
how
to
install
the
inverter
and
connect
it
to
the
grid
-
tied
solar
system
(
including
the
connection
between
solar
modules
,
public
grid
and
inverter
)
.
Read
this
chapter
carefully
and
ensure
all
installation
requirements
are
met
before
installation
.
Only
qualified
electricians
are
allowed
to
install
the
inverter
.
4.1
Unpacking
confirmation
The
inverter
has
been
thoroughly
tested
and
rigorously
checked
before
delivery
,
but
damage
may
still
occur
during
transportation
.
Before
unpacking
,
check
carefully
whether
the
product
information
in
the
order
is
consistent
with
that
on
the
nameplate
of
the
package
box
and
whether
the
product
package
is
intact
.
If
any
damage
is
detected
,
please
contact
the
shipping
company
or
the
supplier
directly
.
Please
also
provide
photos
of
the
damage
to
get
our
fastest
and
best
service
.
Store
the
idled
inverter
in
its
original
package
and
take
anti
-
moisture
and
anti
-
dust
measures
.
After
taking
the
inverter
out
of
the
box
,
check
the
following
items
:
(
1
)
Confirm
the
main
body
of
the
inverter
is
intact
and
free
from
any
damage
;
(
2
)
Confirm
there
is
operation
manual
,
interface
accessories
and
installation
accessories
inside
the
package
box
;
(
3
)
Confirm
the
deliverables
inside
the
package
box
are
intact
and
complete
;
(
4
)
Check
whether
the
product
information
in
the
order
is
consistent
with
that
on
the
inverter
nameplate
;
(
5
)
The
standard
delivery
list
is
shown
below
.
Standard
deliverables
of
three
-
phase
inverter
:
2
3
5
6
7
Fig
4.1
Deliverables
of
100
-
136
kW
three
-
phase
inverter
15

Three
-
phase
photovoltaic
grid
-
connected
inverter
Installation
Table
4
-
1
Deliverables
of
three
-
phase
inverter
Quantity
No
Name
Inverter
1
1
Installation
bracket
2
1
DC
connector
10
pairs
(
100
-
120
kW
)
/
12
pairs
(
136
kW
)
3
4
Document
1
5
MiOcombination
bolt
4
2
6
M
5
combination
bolt
AC
ring
terminal
7
4
Check
above
-
mentioned
items
carefully
and
if
any
question
,
contact
the
supplier
immediately
.
4.2
Preparation
before
installation
4.2
.
1
Installation
tool
Table
4
-
2
List
of
installation
tool
No
Installation
tool
Purpose
1
Marker
Indicate
the
installation
hole
2
Electric
drill
Drill
holes
in
the
bracket
or
on
the
wall
3
Hammer
Knock
on
the
expansion
bolt
4
Adjustable
wrench
Fix
the
installation
bracket
Tighten
the
anti
-
theft
screw
and
disassemble
AC
junction
box
5
Inner
hex
screwdriver
“
Slotted
”
or
“
cross
-
head
”
screwdriver
AC
wiring
6
Measure
the
insulation
performance
and
grounding
impedance
7
Megameter
8
Multimeter
Check
the
circuit
and
measure
AC
/
DC
voltage
9
Electric
soldering
iron
Solder
the
communication
cable
10
Wire
crimper
Crimp
DC
terminal
11
Hydraulic
clamp
Crimp
ring
terminal
for
AC
wiring
16
This manual suits for next models
1
Table of contents
Other V-TAC Inverter manuals

V-TAC
V-TAC VT-6603105 User manual

V-TAC
V-TAC 11390 User manual

V-TAC
V-TAC VT-6607136 User manual

V-TAC
V-TAC VT-6608303 User manual

V-TAC
V-TAC VT-6605305 User manual

V-TAC
V-TAC AF6K-SL User manual

V-TAC
V-TAC 23070 User manual

V-TAC
V-TAC VT-6607105 User manual

V-TAC
V-TAC SUN-5K-SG04LP3-EU User manual

V-TAC
V-TAC VT-6607005 User manual

V-TAC
V-TAC VT-66036103 User manual

V-TAC
V-TAC SUN-6K-SG05LP1-EU User manual

V-TAC
V-TAC 11514 User manual

V-TAC
V-TAC VT-6607036 User manual

V-TAC
V-TAC VT-66036103 User manual

V-TAC
V-TAC VT-66036103 User manual

V-TAC
V-TAC 11381 User manual

V-TAC
V-TAC VT-6605105 User manual

V-TAC
V-TAC VT-6605103 User manual

V-TAC
V-TAC Deye SUN-8K-SG01LP1-EU User manual