VE4080AL
IP PoE One-Way Flexhorn
INTRODUCTION
The VE4080AL IP PoE One-Way Flexhorn
provides for one-way communication when used in
a VoIP based intercom/paging system.
SPECIFICATIONS
Access Methods
PBX, FXO Port w/VE801x
POTS telephone set w/VE801x
FXS Port /VE802x
SIP telephone system
VE6025 Applications Server
Features
RJ-45 for network connection
LED Status Indicator
Network activity LEDs
Power over Ethernet (PoE) 802.3af compatible
Dimensions/Weight VE4080AL
Horn
6.80” H x 8.30” W x 3.30” D
(17.27 cm) x (21.08 cm) x (8.38 cm)
Weight: 2.10 lbs. (0.95 kg)
Network Interface
1.62” H x 5.63” W x 3.45” D
(4.11 cm) x (14.30 cm) x (8.73 cm)
with brackets –8.22” W (20.87 cm)
Weight: 2.10 lbs. (0.95 kg)
Network Requirements
Download the latest network requirements from
www.valcom.com/esd
Nominal Power Requirements
Via 802.3af PoE Ethernet Switch: Class 3
(12.95W)
Environment
Network Interface
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
PSE: (Power Sourcing Equipment) to be compliant
IEEE 802.3af
Horn:
Suitable for indoor or outdoor installation
Packing List
Precautionary Designations
Qty
Item
1
Network Interface
1
VE4080AL Horn
1
VSP Document
1
VM-186 RJ-45 Connector
4
Rubber Pads
4
Wood Screws
2
RJ-45 Patch Cables

2 947828
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated in
a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and if not installed and used
in accordance with the instruction manual, may
cause harmful interference to radio
communications. Operation of this equipment
in a residential area may cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
INSTALLATION
Operation:
Provides one-way intercom via Network connection
to customer telephone system or stand alone
telephone set. Interface to customer telephone
system can be via SIP registration, FXO port or
FXS port (additional equipment required in all
cases). The call button may be programmed to
initiate a call to one of the above telephone system
interfaces. When the call is answered, a hands-free
communications path is established to the horn.
Mounting
The VE4080AL Network Interface is designed for
wall or table mounting and must be within 100
meters of the network switch.
Table: Provided with the VE4080AL Network
Interface are four rubber stick on pads. Peel pads
off their carrier backing and place at the four
corners of the bottom of the unit.
Wall: Using the wood screws provided, secure the
VE4080AL Network Interface to the wall.
Mounting (Horn)
FLUSH MOUNT
Using the template packaged with the speaker, draw
the speaker outline on the wall to be cut. Make
appropriate wiring connections and test the speaker
for operation. Using appropriate mounting screws
(not furnished) drill and mount the flange as shown.
UNIVERSAL BRACKET
Loosen or separate the universal bracket leaves by
loosening or removing the handle and hardware.
Using the back leaf as a template, mark the wall
through the mounting holes. Drill and mount to the
wall using appropriate screws (not furnished) or
mount directly to a junction box.
Mount the T-bracket to the back of the horn as
shown using the (2) ½ inch screws provided.
.
IMPORTANT SAFETY INFORMATION
CONSIGNES DE SÉCURITÉ IMPORTANTES
1. Read these instructions.
Lisez ces instructions.
2. Keep these instructions.
Conservez ces instructions.
3. Heed all warnings.
Respectez tous les avertissements.
4. Follow all instructions.
Suivez toutes les instructions.
5. Do not use this apparatus near water.
Ne pas utiliser cet appareil près de l'eau.
6. Clean only with dry cloth.
Nettoyer avec un chiffon sec.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
Ne pas bloquer les ouvertures de ventilation. Installer formément aux instructions du
fabricant.
8. Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including amplifiers) that produce heat.
Ne pas installer à proximité de sources de chaleur telles que radiateurs, registres de
chaleur, poêles ou autres appareils (y compris les amplificateurs) produisant de la chaleur.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wide blade and the third prong are provided for your safety. If
the provided plug does not fit into your outlet consult an electrician for replacement of the
obsolete outlet.
Ne pas contourner le dispositif de sécurité de lafiche polarisée ou de mise à la terre. Une
fiche polarisée possède deux lames dont une plus large que l'autre. Une fiche de terre a
deux lames et une troisième broche de mise à la terre. La lame large et la troisième
broche sont fournies pour votre sécurité. Si la fiche fournie ne rentre pas dans votre prise,
veuillez consulter un électricien pour le remplacement de la prise obsolète.
10.Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles and the point where they exit from the apparatus.
11.Only use attachments/accessories specified by the manufacturer.
N'utilisez que des fixations / accessoires spécifiés par le fabricant.
12. Use only with the cart, stand, tripod, bracket or table specified
by the manufacturer or sold with the apparatus. When a cart is
used, use caution when moving the cart/apparatus combination
to avoid injury from tip-over.
Utilisez uniquement avec le chariot, stand, trépied, support ou table spécifié par le
fabricant ou vendu avec l'appareil. Quand un chariot est utilisé, Soyez prudent lorsque
vous déplacez l'ensemble chariot / appareil pour éviter des blessures dues au
renversement.
13. Unplug this apparatus during lightning storms or when unused for a long period of time.
Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas utilisé pendant une
longue période de temps.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way. Such as when the power supply cord or plug is
damaged, liquid has been spilled, objects have fallen into the apparatus or the
apparatus has been exposed to rain or moisture and does not operate normally or has
been dropped.
Confiez toute réparation à un personnel qualifié. Une réparation est nécessaire lorsque
l'appareil a été endommagé de quelquefaçon. Parexemple lorsque le cordon
d'alimentation oula fiche est endommagé, du liquide a été renversé, si des objets sont
tombés dans l'appareil ou le appareil a été exposé à la pluie ou à l'humidité et ne
fonctionne pas normalement ou s'il est tombé.

3 947828
Power Connections
The only method of powering a VE4080AL Network
Interface is via a Power over Ethernet (PoE) switch
or power injector meeting the 802.3af specification.
Make all required signal connections before
connecting to Ethernet switch or power injector
meeting the 802.3af specification.
Network Connection
The VE4080AL Network Interface has one RJ-45
network connector and one RJ-45 horn connector.
Use a standard Ethernet patch cable to connect
the NETWORK connector of the VE4080AL
Network Interface to a PoE Ethernet switch.
Signal Connections
Audio output connection is made from the Signal
Output. The RJ-45 connector on the horn is
connected directly to the RJ-45 Signal Output
socket on the IP Link. See Figure 1.
If additional length is required, any standard
T568B extension may be used. See Figure 2.
Status Indicator Lights
The VE4080AL has 2 status indication lights on the
front panel:
Green LED: (Link) Indicates Ethernet connection
when illuminated.
Yellow LED: (Activity) Indicator flashes to indicate
network activity.
Setup
Information specific to your application will need to
be programmed into the VE4080AL using a
computer. The PC used for programming should
be connected to the same subnet as the
VE4080AL. Setup will be done using the VIP-102B
IP Solutions Setup Tool. The IP Solutions Setup
Tool is available for download on the Valcom
website.
TECHNICAL ASSISTANCE
Assistance in troubleshooting is available from the
factory. When requesting assistance, you should
call from the job site Call (877) 427-2166 and ask
for Valcom Engineered Solutions Technical
Support, or visit our website at
www.ValcomES.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
Information is subject to change
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of
the specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800

4 947828
SIGNAL OUTPUT NETWORK
350' MAXIMUM DISTANCE
FLEXHORN
NETWORK
INTERFACE
NETWORK
CONNECTION
VM-186
RJ45
WHITE/GREEN
GREEN
WHITE/BROWN
BROWN
BROWN
BLUE
WHITE/BLUE
BLUE
WHITE/ORANGE
ORANGE
WHITE/GREEN
GREEN
WHITE/BROWN
BROWN
WHITE/BLUE
BLUE
WHITE/ORANGE
ORANGE
SIGNAL OUTPUT NETWORK
350' MAXIMUM DISTANCE
FLEXHORN
NETWORK
INTERFACE
NETWORK
CONNECTION
RJ-45
TYPICAL 568B
RJ-45 JACK
CAT 3/5/6
Figure 1
Figure 2

5 947828
UNIVERSAL BRACKET WITH CLAMP
SURFACE MOUNTED WITH A
UNIVERSAL MOUNTING BRACKET
ATTACH CLAMP TO HORN ATTACH FLEXHORN TO BEAM
USING THE TEMPLATE, MARK LOCATION OF
OPENING AND MOUNTING HOLES ON WALL.
DRILL HOLES APPROPRIATE TO MOUNTING
HARDWARE AND CUT OUT THE OPENING.
HOLDING FLEXHORN FIRMLY AGAINST A FLAT
SURFACE, DRILL THROUGH EACH MOUNTING BOSS
AS SHOWN.
FLUSH MOUNTING IN A STUD WALL
INSTALLED WITH MOUNTING SCREWS
OR CONSTRUCTION CEMENT.
PENDANT MOUNTING WITH
OPTIONAL CHAIN AND
'EYE' SCREW
OPTIONAL V-9805
VANDAL RESISTANT ENCLOSURE
OTHER MOUNTING OPTIONS:
FLUSH MOUNT USING MOUNTING SCREWS:
"C" CLAMP FOR "I" BEAM MOUNTING
UNIVERSAL BRACKET
Table of contents
Other Valcom Security System manuals
Popular Security System manuals by other brands

iiquu
iiquu SENSOR ALARM installation guide

Vip-Vision
Vip-Vision SLR-B180-4W installation manual

Tuffy
Tuffy 012 installation instructions

Chuango
Chuango A11 user manual

Uplink
Uplink 2550 Installation, operations and programming guide

AEI Security & Communications
AEI Security & Communications SOLARGUARD SG4000 Installation & user guide