Vega VEGABAR 81 User manual

Operating Instructions
Pressure transmitter with chemical seal
VEGABAR 81
HART and accumulator pack
Document ID: 45026

2
Contents
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
Contents
1 About this document ............................................................................................................... 4
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety ......................................................................................................................... 5
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use................................................................................................................ 5
2.3 Warning about incorrect use............................................................................................. 5
2.4 General safety instructions............................................................................................... 5
2.5 EU conformity................................................................................................................... 6
2.6 NAMUR recommendations .............................................................................................. 6
2.7 Installation and operation in the USA and Canada ........................................................... 6
2.8 Environmental instructions ............................................................................................... 6
3 Product description ................................................................................................................. 7
3.1 Conguration.................................................................................................................... 7
3.2 Principle of operation........................................................................................................ 8
3.3 Packaging, transport and storage................................................................................... 10
3.4 Accessories.................................................................................................................... 11
4 Mounting................................................................................................................................. 12
4.1 General instructions ....................................................................................................... 12
4.2 Ventilation and pressure compensation.......................................................................... 14
4.3 Process pressure measurement..................................................................................... 15
4.4 Level measurement........................................................................................................ 17
5 Connecting to power supply................................................................................................. 18
5.1 Connection of the battery charger .................................................................................. 18
5.2 Wiring plan ..................................................................................................................... 18
5.3 Switch-on phase............................................................................................................. 19
6 Set up with the display and adjustment module ................................................................ 21
6.1 Insert display and adjustment module............................................................................ 21
6.2 Adjustment system......................................................................................................... 22
6.3 Measured value indication.............................................................................................. 23
6.4 Parameter adjustment - Quick setup .............................................................................. 24
6.5 Parameter adjustment - Extended adjustment................................................................ 24
6.6 Saving the parameterisation data................................................................................... 37
7 Setup with PACTware............................................................................................................. 38
7.1 Connect the PC.............................................................................................................. 38
7.2 Parameter adjustment with PACTware............................................................................ 38
7.3 Saving the parameterisation data................................................................................... 39
8 Set up with other systems .................................................................................................... 40
8.1 DD adjustment programs ............................................................................................... 40
8.2 Field Communicator 375, 475 ........................................................................................ 40
9 Diagnosis, asset management and service ........................................................................ 41
9.1 Maintenance .................................................................................................................. 41
9.2 Diagnosis memory ......................................................................................................... 41
9.3 Asset Management function........................................................................................... 42

3
Contents
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
9.4 Rectify faults................................................................................................................... 45
9.5 Exchanging the electronics module................................................................................ 45
9.6 Software update ............................................................................................................. 45
9.7 How to proceed if a repair is necessary.......................................................................... 46
10 Dismount................................................................................................................................. 47
10.1 Dismounting steps.......................................................................................................... 47
10.2 Disposal ......................................................................................................................... 47
11 Supplement ............................................................................................................................ 48
11.1 Technical data ................................................................................................................ 48
11.2 Chemical seal with vacuum applications........................................................................ 56
11.3 Dimensions .................................................................................................................... 60
11.4 Industrial property rights................................................................................................. 67
11.5 Trademark ...................................................................................................................... 67
Safety instructions for Ex areas
TakenoteoftheExspecicsafetyinstructionsforExapplications.
These instructions are attached as documents to each instrument
with Ex approval and are part of the operating instructions.
Editing status: 2020-05-12

4
1 About this document
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
1 About this document
1.1 Function
This instruction provides all the information you need for mounting,
connection and setup as well as important instructions for mainte-
nance,faultrectication,theexchangeofpartsandthesafetyofthe
user. Please read this information before putting the instrument into
operation and keep this manual accessible in the immediate vicinity
of the device.
1.2 Target group
This operating instructions manual is directed to trained personnel.
Thecontentsofthismanualmustbemadeavailabletothequalied
personnel and implemented.
1.3 Symbols used
Document ID
This symbol on the front page of this instruction refers to the Docu-
ment ID. By entering the Document ID on www.vega.com you will
reach the document download.
Information, note, tip: This symbol indicates helpful additional infor-
mation and tips for successful work.
Note: This symbol indicates notes to prevent failures, malfunctions,
damage to devices or plants.
Caution: Non-observance of the information marked with this symbol
may result in personal injury.
Warning: Non-observance of the information marked with this symbol
may result in serious or fatal personal injury.
Danger: Non-observance of the information marked with this symbol
results in serious or fatal personal injury.
Ex applications
This symbol indicates special instructions for Ex applications.
• List
The dot set in front indicates a list with no implied sequence.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.

5
2 For your safety
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
2 For your safety
2.1 Authorised personnel
All operations described in this documentation must be carried out
onlybytrained,qualiedpersonnelauthorisedbytheplantoperator.
During work on and with the device, the required personal protective
equipment must always be worn.
2.2 Appropriate use
The VEGABAR 81 is a pressure transmitter for process pressure and
hydrostatic level measurement. Due to the integrated accumulator the
instrument is particularly suitable as a portable measuring system or
test sensor for special applications.
Youcannddetailedinformationabouttheareaofapplicationin
chapter "Product description".
Operational reliability is ensured only if the instrument is properly
usedaccordingtothespecicationsintheoperatinginstructions
manual as well as possible supplementary instructions.
2.3 Warning about incorrect use
Inappropriate or incorrect use of this product can give rise to applica-
tion-specichazards,e.g.vesseloverllthroughincorrectmounting
or adjustment. Damage to property and persons or environmental
contamination can result. Also, the protective characteristics of the
instrument can be impaired.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and directives.The instrument must only be operated in a
technicallyawlessandreliablecondition.Theoperatorisresponsi-
ble for the trouble-free operation of the instrument. When measuring
aggressive or corrosive media that can cause a dangerous situation
if the instrument malfunctions, the operator has to implement suitable
measures to make sure the instrument is functioning properly.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.Forsafety
reasons,onlytheaccessoryspeciedbythemanufacturermustbe
used.
To avoid any danger, the safety approval markings and safety tips on
the device must also be observed.

6
2 For your safety
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
2.5 EU conformity
ThedevicefullsthelegalrequirementsoftheapplicableEUdirec-
tives.ByaxingtheCEmarking,weconrmtheconformityofthe
instrument with these directives.
The EU conformity declaration can be found on our homepage.
Duetothedesignofitsprocessttings,thedevicedoesnotsubject
of EU pressure device directive if it is operated at process pressures
≤200bar.1)
2.6 NAMUR recommendations
NAMUR is the automation technology user association in the process
industry in Germany. The published NAMUR recommendations are
acceptedasthestandardineldinstrumentation.
ThedevicefullstherequirementsofthefollowingNAMURrecom-
mendations:
• NE 21 – Electromagnetic compatibility of equipment
• NE 43 – Signal level for fault information from measuring transduc-
ers
• NE53–Compatibilityofelddevicesanddisplay/adjustment
components
• NE107–Self-monitoringanddiagnosisofelddevices
For further information see www.namur.de.
2.7 Installation and operation in the USA and
Canada
This information is only valid for USA and Canada. Hence the follow-
ing text is only available in the English language.
Installations in the US shall comply with the relevant requirements of
theNationalElectricalCode(ANSI/NFPA70).
Installations in Canada shall comply with the relevant requirements of
the Canadian Electrical Code.
2.8 Environmental instructions
Protection of the environment is one of our most important duties.
That is why we have introduced an environment management system
with the goal of continuously improving company environmental pro-
tection.Theenvironmentmanagementsystemiscertiedaccording
to DIN EN ISO 14001.
Pleasehelpusfullthisobligationbyobservingtheenvironmental
instructions in this manual:
• Chapter "Packaging, transport and storage"
• Chapter "Disposal"
1) Exception:Versions with measuring ranges from 250 bar. These are subject
of the EU Pressure Device Directive.

7
3 Product description
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
3 Product description
3.1 Conguration
The scope of delivery encompasses:
• Sensor with integrated accumulator
• Battery charger
The further scope of delivery encompasses:
• Documentation
– Quick setup guide VEGABAR 81
– Testcerticateforpressuretransmitters
– Instructions for optional instrument features
– Ex-specic"Safety instructions" (with Ex versions)
– Ifnecessary,furthercerticates
Information:
Optional instrument features are also described in this operating
instructions manual.The respective scope of delivery results from the
orderspecication.
This operating instructions manual applies to the following instrument
versions:
• Hardware from 1.0.0
• Software from 1.3.5
Note:
Youcanndthehardwareandsoftwareversionoftheinstrumentas
follows:
• On the type plate of the electronics module
• In the adjustment menu under "Info"
Thetypelabelcontainsthemostimportantdataforidenticationand
use of the instrument:
7
6
4
5
2
3
1
Fig. 1: Layout of the type label (example)
1 Product code
2 Field for approvals
3 Technical data
4 Serial number of the instrument
5 QR code
6 Symbol of the device protection class
7 ID numbers, instrument documentation
Scope of delivery
Scope of this operating
instructions
Type label

8
3 Product description
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
The type label contains the serial number of the instrument. With it
youcanndthefollowinginstrumentdataonourhomepage:
• Product code (HTML)
• Delivery date (HTML)
• Order-specicinstrumentfeatures(HTML)
• Operating instructions and quick setup guide at the time of ship-
ment (PDF)
• Order-specicsensordataforanelectronicsexchange(XML)
• Testcerticate(PDF)-optional
Move to "www.vega.com"andenterinthesearcheldtheserial
number of your instrument.
Alternatively, you can access the data via your smartphone:
• Download the VEGA Tools app from the "Apple App Store" or the
"Google Play Store"
• Scan the DataMatrix code on the type label of the instrument or
• Enter the serial number manually in the app
3.2 Principle of operation
VEGABAR 81 is suitable for applications in virtually all industries. It is
used for the measurement of the following pressure types.
• Gauge pressure
• Absolute pressure
• Vacuum
Measured products are gases, vapours and liquids.
The chemical seal systems of VEGABAR 81, which are optimally
adapted to the process, also allow measurement of highly corrosive
and hot products.
The VEGABAR 81 is suitable for the measurement of the following
process variables:
• Process pressure
• Level
Fig. 2: Process pressure measurement VEGABAR 81
Serial number - Instru-
ment search
Application area
Measured products
Measured variables

9
3 Product description
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
The VEGABAR 81 is equipped with a chemical seal. It consists of a
stainless steel diaphragm and a transmission liquid.
A chemical seal has two tasks:
• Separation of the sensor element from the medium
• Transmission of the process pressure to the sensor element
1
2
3
4
Fig. 3: Conguration of a chemical seal
1 Sensor element
2 Sealed screw
3 Transmission liquid
4 Stainless steel diaphragm
Thechemicalsealisavailableindierentversions,seechapter
"Dimensions".
The process pressure acts on the sensor element via the isolat-
ing diaphragm.The process pressure causes a resistance change
which is converted into a corresponding output signal and output as
measured value.
Measuringrangesupto40bar:piezoresistivesensorelementwith
a transmission liquid, measuring ranges from 100 bar: a dry strain
gauge (DMS) sensor element.
1
3 4
2
Fig. 4: Conguration of a measuring system with piezoresistive sensor element
1 Sensor element
2 Base element
3 Transmission liquid
4 Diaphragm
Chemical seal
Measuring system

10
3 Product description
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
1
2
3
Fig. 5: Conguration of a measuring system with strain gauge (DMS) sensor
element
1 Sensor element
2 Process diaphragm
3 Pressure cylinder
Relative pressure: the measuring cell is open to the atmosphere.
The ambient pressure is detected in the measuring cell and compen-
sated.Itthushasnoinuenceonthemeasuredvalue.
Absolute pressure: the measuring cell contains vacuum and is
encapsulated.The ambient pressure is not compensated and does
henceinuencethemeasuredvalue.
The measuring system is completely welded and thus sealed against
the process.
Theprocessttingissealedagainsttheprocessbyasuitableseal.It
mustbeprovidedbythecustomer,dependingontheprocesstting
also included in the scope of delivery, see chapter "Technical data",
"Materials and weights".
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging consists of environment-friendly, recyclable card-
board. For special versions, PE foam or PE foil is also used. Dispose
of the packaging material via specialised recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
Pressure types
Seal concept
Packaging
T
ransport
Transport inspection
Storage

11
3 Product description
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
• Not in the open
• Dry and dust free
• Not exposed to corrosive media
• Protected against solar radiation
• Avoiding mechanical shock and vibration
• Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
• Relative humidity 20 … 85 %
With instrument weights of more than 18 kg (39.68 lbs) suitable and
approved equipment must be used for lifting and carrying.
3.4 Accessories
The instructions for the listed accessories can be found in the down-
load area on our homepage.
The display and adjustment module is used for measured value indi-
cation, adjustment and diagnosis.
The integrated Bluetooth module (optional) enables wireless adjust-
ment via standard adjustment devices.
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC.
The protective cover protects the sensor housing against soiling and
intense heat from solar radiation.
Screwedangesareavailableindierentversionsaccordingtothe
following standards: DIN 2501, EN 1092-1, BS 10, ASME B 16.5,
JIS B 2210-1984, GOST 12821-80.
Welded sockets are used to connect the sensors to the process.
Threaded adapters enable simple adaptation of sensors with stand-
ardthreadedttings,e.g.toprocess-sidehygieneconnections.
Storage and transport
temperature
Lifting and carrying
PLICSCOM
VEGACONNECT
Protective cover
Flanges
Welded sockets and
adapters

12
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
4 Mounting
4.1 General instructions
Note:
For safety reasons, the instrument must only be operated within the
permissibleprocessconditions.Youcannddetailedinformationon
the process conditions in chapter "Technical data" of the operating
instructions or on the type label.
Hence make sure before mounting that all parts of the instrument ex-
posed to the process are suitable for the existing process conditions.
These are mainly:
• Active measuring component
• Processtting
• Process seal
Process conditions in particular are:
• Process pressure
• Process temperature
• Chemical properties of the medium
• Abrasionandmechanicalinuences
Protect your instrument against moisture ingress through the following
measures:
• Use a suitable connection cable (see chapter "Connecting to
power supply")
• Tighten the cable gland or plug connector
• Lead the connection cable downward in front of the cable entry or
plug connector
This applies mainly to outdoor installations, in areas where high
humidity is expected (e.g. through cleaning processes) and on cooled
or heated vessels.
Note:
Makesurethatthedegreeofcontaminationspeciedinchapter
"Technical data" meets the existing ambient conditions.
Note:
Make sure that during installation or maintenance no moisture or dirt
can get inside the instrument.
To maintain the housing protection, make sure that the housing lid is
closed during operation and locked, if necessary.
Deviceswiththreadedttingarescrewedintotheprocessttingwith
a suitable wrench via the hexagon.
See chapter "Dimensions"forwrenchsize.
Process conditions
Protection against mois-
ture
Screwing in

13
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
Warning:
The housing or the electrical connection may not be used for screw-
ing in! Depending on the device version, tightening can cause dam-
age, e. g. to the rotation mechanism of the housing.
If there is strong vibration at the mounting location, the instrument
version with external housing should be used. See chapter "External
housing".
Thepermissibleprocesspressurerangeisspeciedby"MWP"(Maxi-
mum Working Pressure) on the type label, see chapter "Structure".
The MWP takes the element of the measuring cell and processing
ttingcombinationwiththeweakestpressureintoconsiderationand
mayappliedpermanently.Thespecicationreferstoareference
temperature of +20 °C (+68 °F). It also applies when a measuring cell
with a higher measuring range than the permissible pressure range of
theprocessttingisinstalledorder-related.
In order to prevent damage to the device, a test pressure may only
exceedthespeciedMWPbrieyby1.5timesatreferencetempera-
ture.Thepressurestageoftheprocessttingaswellastheoverload
resistance of the measuring cell are taken into consideration here
(see chapter "Technical Data").
Inaddition,atemperaturederatingoftheprocesstting,e.g.with
anges,canlimitthepermissibleprocesspressurerangeaccording
to the respective standard.
The permissible process pressure range is stated on the type label.
The instrument should only be operated with these pressures if the
mountingaccessoryusedalsofullsthesevalues.Thisshouldbeen-
suredbysuitableanges,weldedsockets,tensionringswithClamp
connections, sealings, etc.
Higher process temperatures often mean also higher ambient
temperatures. Make sure that the upper temperature limits stated in
chapter "Technical data" for the environment of the electronics hous-
ing and connection cable are not exceeded.
1
2
Fig. 6: Temperature ranges
1 Process temperature
2 Ambient temperature
Vibrations
Permissible process
pressure (MWP) - Device
Permissible process
pressure (MWP) - Mount-
ing accessory
Temperature limits

14
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
4.2 Ventilation and pressure compensation
Thelterelementintheelectronicshousinghasthefollowingfunc-
tions:
• Ventilation of the electronics housing
• Atmospheric pressure compensation (with relative pressure meas-
uring ranges)
Caution:
Thelterelementcausesatime-delayedpressurecompensation.
Whenquicklyopening/closingthehousingcover,themeasuredvalue
can change for approx. 5 s by up to 15 mbar.
Foraneectiveventilation,thelterelementmustbealwaysfreefrom
buildup.Incaseofhorizontalmounting,turnthehousingsothatthe
lterelementpointsdownwardaftertheinstrumentisinstalled.This
provides better protection against buildup.
Caution:
Donotuseahigh-pressurecleaner.Thelterelementcouldbedam-
aged, which would allow moisture into the housing.
Thefollowingparagraphsdescribehowthelterelementisarranged
inthedierentinstrumentversions.
1 2 3
6
6
6 6
6
5
4
Fig. 7: Position of the lter element
1 Plastic, stainless steel single chamber (precision casting)
2 Aluminium - single chamber
3 Stainless steel single chamber (electropolished)
4 Plastic double chamber
5 Aluminium, stainless steel double chamber housing (precision casting)
6 Filter element
With the following instruments a blind plug is installed instead of the
lterelement:
Filter element - Function
Filter element - Position

15
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
• InstrumentsinprotectionIP66/IP68(1bar)-ventilationviacapillar-
ies in non-detachable cable
• Instruments with absolute pressure
4.3 Process pressure measurement
Keep the following in mind when setting up the measuring system:
• Mount the instrument above the measuring point
Possiblecondensationcanthendrainointotheprocessline.
1
2
3
Fig. 8: Measurement setup for process pressure measurement of gases in
pipelines
1 VEGABAR 81
2 Blocking valve
3 Pipeline
Keep the following in mind when setting up the measuring system:
• Connect via a siphon
• Do not insulate the siphon
• Fill the siphon with water before setup
Measurement setup in
gases
Measurement setup in
vapours

16
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
1
4
3
2
1
2
3
4
Fig. 9: Measurement setup for the process pressure measurement of gases in
pipelines
1 VEGABAR 81
2 Blocking valve
3 Siphon in U or circular form
4 Pipeline
A protective accumulation of water is formed through condensation
in the pipe bends. Even in applications with hot steam, a medium
temperature < 100 °C on the transmitter is ensured.
Keep the following in mind when setting up the measuring system:
• Mount the instrument below the measuring point
Theeectivepressurelineisalwayslledwithliquidandgasbubbles
can bubble up to the process line.
3
1
2
Fig. 10: Measurement setup for the process pressure measurement of liquids in
pipelines
1 VEGABAR 81
2 Blocking valve
3 Pipeline
Measurement setup in
liquids

17
4 Mounting
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
4.4 Level measurement
Keep the following in mind when setting up the measuring system:
• Mount the instrument below the min. level
• Donotmounttheinstrumentclosetothellingstreamoremptying
area
• Mount the instrument so that it is protected against pressure
shocks from the stirrer
Fig. 11: Measurement setup for the level measurement
Measurement setup

18
5 Connecting to power supply
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
5 Connecting to power supply
5.1 Connection of the battery charger
We recommended charging the integrated accumulator completely
beforesettinguptheinstrument.Youcanndthechargingtimein
chapter "Technical data".
The battery charger is plugged into a socket in the supply room, see
chapter "Wiring plan".
The LEDs in the supply room show the charging process and condi-
tion of the accumulator, see chapter "Wiring plan".
5.2 Wiring plan
2
1
Fig. 12: Position of the power supply and electronics compartment
1 Supply room (accumulator)
2 Electronics compartment
5678
4...20mA
2
12
+
( ) (-)
1
Fig. 13: Electronics compartment - double chamber housing
1 Internal connection to the connection compartment
2 Contact pins for the display and adjustment module
Overview
Electronics compartment

19
5 Connecting to power supply
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
2
4
3
5
0
5
1
6
2
7
3
8
4
9
modes
4 ON/OFF
3 ON/OFF 1h
1,2 OFF
Charge Accu
5..9 auto cycle
12
+
( ) (-)
1
Fig. 14: Supply room
1 Internal connection of the socket for the battery charger
2 Mode switch
3 LED green, charging process
4 LED yellow, charging status
5 Socket for the battery charger
The mode switch enables the selection of the following modes:
• 0=sensoro,LEDsshowtheaccumulatorstatus
• 1,2=sensoro,LEDso
• 3 = sensor on for 1 hour after pressing a key (delivery status)
• 4=sensorpermanentlyon,switchingon/oviabutton
• 5 = sensor is switched on every 30 minutes for 3 minutes
• 6 = sensor is switched on every hour for 3 min.
• 7 = sensor is switched on every 6 hours for 3 minutes
• 8 = sensor is switched on every 12 hours for 3 minutes
• 9 = sensor is switched on every 24 hours for 3 minutes
ThegreenLEDcharacterizesthechargingprocess:
• LEDashes=Accumulatorischarging
• LED lights = accumulator is full, battery charger should be
unplugged (accumulator life time)
After pressing the key or changing the mode the yellow LED shows
the accumulator status for approximately 10 s as follows:
• LED lights = accumulator is full
• LEDashes=accumulatorshouldbecharged
• LEDo=accumulatorisempty
5.3 Switch-on phase
Theinstrumentisswitchedonandobymeansofabuttonoutside
on the housing.
Supply room

20
5 Connecting to power supply
VEGABAR 81 • HART and accumulator pack
45026-EN-200529
1
Fig. 15: Switch on/o button outside on the housing
1 On/O button
After switching on, the instrument carries out a self-check for approxi-
mately 30 s:
• Internal check of the electronics
• Indication of a status message, e.g. "F 105 Determine measured
value" on the display
Then the actual measured value is output to the signal cable.The
value takes into account settings that have already been carried out,
e.g. default setting.
Other manuals for VEGABAR 81
16
Table of contents
Other Vega Transmitter manuals

Vega
Vega VEGADIF 65 User manual

Vega
Vega VEGABAR 82 User manual

Vega
Vega VEGABAR 81 User manual

Vega
Vega VEGABAR 29 User manual

Vega
Vega VEGABAR 87 User manual

Vega
Vega VEGABAR 82 User manual

Vega
Vega VEGABAR 54 User manual

Vega
Vega T-677 Series User manual

Vega
Vega VEGABAR 87 User manual

Vega
Vega VEGABAR 54 User manual

Vega
Vega VEGABAR 54 User manual

Vega
Vega VEGABAR 86 User manual

Vega
Vega VEGABAR 66 User manual

Vega
Vega VEGABAR S 14 User manual

Vega
Vega VEGABAR 81 User manual

Vega
Vega VEGABAR 83 User manual

Vega
Vega VEGADIF 85 User manual

Vega
Vega VEGABAR 87 User manual

Vega
Vega VEGABAR 83 User manual

Vega
Vega VEGABAR 66 User manual