VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Original Instrucons : Installaon, Operaon & Maintenance ManualOriginal Instrucons : Installaon, Operaon & Maintenance Manual
WEEE Direcve
Ahe end oheir useful life the packaging and product should
be disposed of viaasuitable recycling centre. Do not dispose of
with normal household waste. Do not burn.
Standards
EURO fans conform to all relevant Brish and European
standards and direcves. Further informaon is available
from VES Andover Ltd on request
Pleaseensure thahisdocumenspassed on to theenduser
We reserve the right to alter the specificaon without noce
©VES Andover Ltd. 2010. No part of this publicaon may be
photocopied or otherwise reproduced without the prior
permission in wring of VES Andover Ltd.
Wiring Diagrams
Standard Wiring
(Typical Installaon)
Specificaon
Power Supply 230VAC 50Hz
Operang Temperature 0~40°C
Insulaon Class Double insulated
Motor Protecon IPX2
deveelSepyTrotoM
0562)mpr(deepS
Power (W) (EURO100/150)15/20
Current (A)(EURO100/150)0.12/0.13
Warranty
The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.
Light (oponal)
Fuse
Remote/
Light Switch
Double Pole
Isolang Switch
L
N
Original Instrucons : Installaon, Operaon & Maintenance Manual
Installaon connued
Make the
connecon as per
the appropriate wiring
diagram as above. Secure the cable
using the cord grip provided. Replace the
terminal cover. The cable should exit through
the side of the ductwork adjacent to the motor.
Grommet as required.
Remove the terminal
cover, retaining all
fixings
IMPORTANT
All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulaons.
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes aer electrical disconnecon before
aempng access. This will allow any moving parts to come to a rest.
Using the EURO mounng
bracket, determine a
mounng posion
Place the fan into posion taking
note of the direcon of airflow
arrow.
Wire the fan as per
wiring diagram &
instrucons
Unclip/open the mounng bracket
and secure into posion using the
fixings provided. Plug mounng
holes as required
Replace the fan body and refasten
the mounng bracket, holding the
fan now into place
Secure flexible ducng to
both spigots using jubilee clips
or strangle band
IMPORTANT
Before aempng to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes aer electrical disconnecon before
aempng access. This will allow any moving parts to come to a rest.
Maintenance
These fans require lile in the way of maintenance.
1. Before aempng to clean, ensure that the fan is isolated completely
from the mains supply.
2. Loosen the collar and carefully clean the fan with a damp, lint free cloth.
Thoroughly dry and refit.
3. immerse the fan in water or other liquids to clean any other parts
sirollepmiehtfI.nafehtfo
damaged or soiled replace the fan unit.
No other maintenance is required. For replacement fans or install kits
please visit
Do not
Never use strong solvents to clean the fan.
www.vesdirect.co.uk
Fan
Terminals
L
N
IMPORTANT
The fan must be fused at 3A unless it forms part of a 5A lighng circuit.
An isolator should be installed to isolate all poles to the fan.