IMPORTANT
Before attempting to carry out any work on our units, all accompanying
documentation including warning labels on the unit must be referenced.
Should it be necessary to remove any component ensure that these are
secured into position once reinstalled. It is critical that after any
maintenance work has been conducted that all components removed
/replaced be refitted correctly by a competent engineer.
POLO100/150
Bathroom Extract Fans
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: v[email protected] web: www.ves.co.uk
Original Instructions : Installation, Operation & Maintenance Manual
ID Ref 846b 04/10
Original Instructions : Installation, Operation & Maintenance Manual Original Instructions : Installation, Operation & Maintenance Manual
This manual must be read in full before Installation, Operation and
Maintenance of the units supplied. Please ensure that this document is
passed to the end user. This manual forms an integral part of the product
and should be kept for the working life of the product. Additional copies of
this and supporting documents are available by contacting VES or by
visiting www.ves.co.uk and following the 'Download O & M's' link.
IMPORTANT
The following symbols used within this document refer to potential dangers
or advice for safe operation
Indicates hazards associated with electric current and high
voltages
Indicates hazards that require safety advice for personnel
and/or potential unit/property damage
Indicates important information
POLO fans are suitable for installation in Zone 2 and outside the zoning area
(see below)
.
IMPORTANT
EXCEPT all HM/AT & AS/HM/AT models which MUST be
mounted outside the zoning area
All POLO fans must be sited and installed in accordance with current IEE
Regulations BS7671 and the appropriate Building Regulations.
POLO fans are suitable for wall or ceiling
mounting except the PC (pull cord) model which is suitable for wall
mounting only.
The fan should be installed in conjunction with an appropriate mounting kit
and consideration must be given to ensure that access to all moving parts of
the fan are restricted when the fan is in use.
Unit Description
The POLO series is range of axial fans suitable for bathroom extract
applications; for full unit details please see the unit specification later in the
document.
Immediately upon receipt of your POLO fan, check there is no damage to
the fan, and that the four fixing screws and matching wall plugs are
included within the ancillary bag.
In the event of any damage having occurred or if any item is found to be
missing, it is essential to inform VES Andover Ltd. within 7 days of delivery
quoting sales order number and the unit type. After this period, VES would
be unable to accept any claim for damaged or missing goods.
Part Number Description
POLO100 or 150 ............................ Standard extract fan
POLO100 or 150/PC .......................Fan c/w pull chord
POLO100 or 150/AT ....................... Fan c/w adjustable timer
POLO100 or 150/HM/AT.................Fan c/w adjustable humidistat & timer
POLO100 or 150/PIR/AT..................Fan c/w PIR sensor & timer
POLO100 or 150/AS ....................... Fan c/w automatic shutter
POLO100 or 150/AS/AT ..................Fan c/w auto shutter & timer
POLO100 or 150/AS/HM/AT............Fan c/w auto shutter, humidistat & timer
POLO100 or 150/AS/PIR/AT............ Fan c/w auto shutter, PIR sensor & timer
Dimensions AB C DØ(mm)
POLO100 156 154 29 55 98
POLO150 209 208 31 69 148
A
BCD
Ø
1
zone
0
zone
2
zone
2
zone
2
zone
600mm
600mm
600mm
2250mm
IMPORTANT
Before attempting to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes after electrical disconnection before
attempting access. This will allow any moving parts to come to a rest.
Fan
Terminals
Mark centre holes on
mounting surface then
drill out
Remove cover from
POLO fan
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: v[email protected] web: www.ves.co.uk
Original Instructions : Installation, Operation & Maintenance Manual Original Instructions : Installation, Operation & Maintenance ManualOriginal Instructions : Installation, Operation & Maintenance Manual
WEEE Directive
At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose of
with normal household waste. Do not burn.
Standards
All POLO fans conform to all relevant British and European
standards and directives. Further information is available
from VES Andover Ltd on request
Please ensure that this document is passed on to the end user
We reserve the right to alter the specification without notice
©VES Andover Ltd. 2009. No part of this publication may be
photocopied or otherwise reproduced without the prior
permission in writing of VES Andover Ltd.
Wire the fan as per
wiring diagram &
instructions
Prepare hole in
mounting surface &
plug mounting holes as
required
Replace front cover
Installation continued Wiring Diagrams
Secure fan backing
plate to mounting
surface
Standard, /AS
(Typical Installation)
/PC, /PIR/AT, /AS/PIR/AT
(Typical Installation)
/AT, /HM/AT, /AS/AT, /AS/HM/AT
(Typical Installation)
Maintenance
1. Before cleaning, isolate the fan completely from the mains supply.
2. Carefully remove the front cover
3. To clean the front cover, either wipe it with a damp, lint free cloth or
wash it in warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts
of the fan.
5. Never use strong solvents to clean the fan.
6. Apart from cleaning, no other maintenance is required.
For replacement fans or install kits please visit www.vesdirect.co.uk
Specification
Power Supply 230V 50Hz
Operating Temperature 0~40°C
Insulation Class Double insulated
Motor Protection IPX4
Motor Type Ball bearing
Speed (rpm) 2650
Power (W) (POLO100/150) 15/25
Current (A) (POLO100/150) 0.1/0.15
(HM/AT & AS/HM/AT IPX2 only)
+-
AT model
2-23
mins
run-on
- +
-+
-+
Movement
sensitivity
2-23 mins
run-on
PIR model
-+
+-
PCB
PCB PCB
-+
+-
HM model
Humidistat
+
-
+
-
2-23 mins
run-on
IMPORTANT
The fan must be fused at 3A unless it forms part of a 5A lighting circuit.
An isolator should be installed to isolate all poles to the fan.
IMPORTANT
All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulations
Warranty
The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.
Fan
Terminals
(Light optional)
(Light optional)
Fuse
Fuse
Fuse
Remote/
Light Switch
Remote/
Light Switch
Double Pole
Isolating Switch
Double Pole
Isolating Switch
Double Pole
Isolating Switch
L
L
L
L
T
LL
N
N
N
N
NN
Fan
Terminals

This manual suits for next models

19

Other VES Fan manuals

VES Colourfan CLE Series User manual

VES

VES Colourfan CLE Series User manual

VES EURO100 User manual

VES

VES EURO100 User manual

VES ecovent EVH User manual

VES

VES ecovent EVH User manual

VES Colourfan Series User manual

VES

VES Colourfan Series User manual

VES ECVD72 User manual

VES

VES ECVD72 User manual

VES MERA250 User manual

VES

VES MERA250 User manual

VES Roundfan RM100/EC Manual

VES

VES Roundfan RM100/EC Manual

VES AX315/4-1 Instruction manual

VES

VES AX315/4-1 Instruction manual

VES POLO150 Instruction manual

VES

VES POLO150 Instruction manual

VES Short Case Axial series Instruction manual

VES

VES Short Case Axial series Instruction manual

VES VENA240 Instruction manual

VES

VES VENA240 Instruction manual

VES Ecovent EVH Series Manual

VES

VES Ecovent EVH Series Manual

VES Ecovent EVHR User manual

VES

VES Ecovent EVHR User manual

VES FALA100/12V/TR User manual

VES

VES FALA100/12V/TR User manual

Popular Fan manuals by other brands

Lindab Versio-R installation instructions

Lindab

Lindab Versio-R installation instructions

IRIT IRV-026 manual

IRIT

IRIT IRV-026 manual

Casablanca M6020-01 user manual

Casablanca

Casablanca M6020-01 user manual

Exodraft RSG manual

Exodraft

Exodraft RSG manual

Goobay 45283 user manual

Goobay

Goobay 45283 user manual

Hinkley MARIN instruction manual

Hinkley

Hinkley MARIN instruction manual

Broan QTR140L quick start guide

Broan

Broan QTR140L quick start guide

Hunter Ridgefield 51107 installation manual

Hunter

Hunter Ridgefield 51107 installation manual

Bimar VM41 instruction manual

Bimar

Bimar VM41 instruction manual

Skov DA 820 LPC Technical user guide

Skov

Skov DA 820 LPC Technical user guide

Sharper Image FLY 01 owner's guide

Sharper Image

Sharper Image FLY 01 owner's guide

ForestAir 13-07009 operating instructions

ForestAir

ForestAir 13-07009 operating instructions

kuzco lighting BAYLOR CF77860 instruction sheet

kuzco lighting

kuzco lighting BAYLOR CF77860 instruction sheet

Express VCDD0110I instructions

Express

Express VCDD0110I instructions

Fantech FADE installation instructions

Fantech

Fantech FADE installation instructions

RWD R419 user manual

RWD

RWD R419 user manual

S&P CAD HE 325 EC V BASIC manual

S&P

S&P CAD HE 325 EC V BASIC manual

Faro Barcelona andros manual

Faro Barcelona

Faro Barcelona andros manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.