SmartOTDR GETTING STARTED MANUAL
Laser safety
The provisions contained in two standards dene the safety procedures to be observed both by users and
by manufacturers when utilizing laser products:
-EN 60825-1: 2001 - Safety of laser products – Part 1: Classication of products, requirements and user
guidelines.
-FDA 21 CFR § 1040.10 - Performance standards for light-emitting products - Laser products.
Due to the range of possible wavelengths, power values and injection characteristics of a laser beam, the
risks inherent in its usage vary. The laser classes form groups representing different safety thresholds.
-VFL option: Laser Class 2.
Due to the reduced dimensions of the optical modules, it is not possible to attach the required warning la-
bels to them. In line with the provisions of Article 5.1 of the EN 60825-1 standard, the laser class identica-
tion labels are shown below:
Ref. standard EN 60825-1, Edition 1.2, 2001-08 FDA21CFR§1040.10
Class 2
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
LASER RAD
IATION - DO NOT
STARE INTO BEAM
CLASS II LASER PRODUCT
CAUTION
The user must take the necessary precautions concerning the optical outputs of the instrument and
follow the manufacturer’s instructions.
AC/DC power supply safety
!
Always use the proper adaptable plug to connect the power supply to an electrical outlet. Viavi is
not responsible for direct or indirect damage including damage to persons or property if the power
supply is not use correctly. For assistance using one of the Viavi supplied adapters (your specic
regional adapter may not be available) please refer to the user manual.
Before connecting a ber into a test module, inspect and clean the module bulkhead and the ber jumper
connectors.
1
Use a video inspection scope (such as P5000i) to verify the connector quality. Follow this simple
“INSPECT BEFORE YOU CONNECT” process
2
Use appropriate cleaning material (e.g. IBC™ cleaner, cotton swab, dust air sprays, etc...) and
re-inspect to conrm.
3
Carefully align the connector and test port prior to mating both
Never force the connector ferrule or insert it with an angle into the test port adapter. Mechanical stress
may permanently damage the ceramic sleeve of the adapter or the end face of the connector.
mart
2
On the Home page, select the Microscope icon.
3
Use Focus control button on Microscope to
adjust focus.
4
Congure the test of the connector.
7
A summary of test results is displayed.
Zones: A - Core / B - Cladding / C - Epoxy /
D - Ferrule
1
Connect the Microscope to the SmartOTDR USB
port.
SETUP
5
Press
RESULTS
to return to Results page
Congure the le storage
6
Display information
on scope & current
test result displayed
mart
1 5’’ HVT Capacitive Screen 8 On/Off
15
Slave Mini USB port
2 Charge indicator 9 Home page
16
VFL connector
3 On indicator
10
Cancel (switch off functions)
17
USB ports (2)
4 File menu
11
Direction & validation keys
18
OTDR port / continuous light
source / power meter
5 Setup menu
12
Results page
6 Start/Stop
13
Buzzer
19
OTDR live port (in-service test)
7 Testing indicator
14
AC/DC Input
20
WIFI or Bluetooth options
15
14 18 1916 17
1
1312111098
765432
20
mart est
2
From the Results page, press .