WARNING
• Read and understand all instructions before attempting to install any Victaulic piping products.
• Depressurize and drain the piping system before attempting to install, remove, adjust, or perform maintenance on any Victaulic products.
• Wear safety glasses, hardhat, and foot protection when working with Victaulic piping products.
• Any activities that require taking the valve out of service may eliminate the fire protection provided by the system. Before removing the
valve from service, notify the authority having jurisdiction. Consideration of a fire patrol should be given for the affected areas.
Failure to follow these instructions could result in serious personal injury and/or property damage.
EXPLODED VIEW DRAWING - AUXILIARY WATER MOTOR ALARM TEST VALVE KIT
4
TO SYSTEM
WATER
SUPPLY
TO WATER
MOTOR ALARM
TO
DRAIN
NORMALLY
CLOSED
(LOCKABLE)
3
4
4
3
1
2
Bill of Materials
1 Auxiliary Water Motor Alarm Test Ball Valve
(Normally Closed - Lockable)
2 Flexible Stainless Steel Braided Hose
3 Female Tee
4 Close Nipple
I-751.VDS/KIT_1
Series 751 FireLock European Alarm Check Valve Stations
AUXILIARY WATER MOTOR ALARM TEST VALVE KIT
I-751.VDS/KITKIT INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
REMOVING THE SYSTEM FROM SERVICE
1. Notify the authority having jurisdiction, remote station alarm
monitors, and those in the affected area that the system is being
taken out of service.
2. Close the water supply main control valve to take the system out of
service.
3. Open the system main drain valve, and allow the system to drain
completely. NOTE: It may be necessary to open the remote system
test valve (inspector’s test connection) and any auxiliary drains in
order to drain the system completely.
INSTALLATION OF THE AUXILIARY WATER MOTOR ALARM
TEST VALVE KIT
WARNING
• Make sure the valve is depressurized and
drained before attempting to remove any
trim from the valve.
Failure to follow this instruction could result
in serious personal injury and/or property
damage.
1. Make sure the valve is completely depressurized and drained.
2. Remove the trim at the locations designated in the exploded view
drawing on page 1.
3. Apply a small amount of pipe joint compound or Teflon* tape to
the external threads of all threaded pipe connections contained in
the kit. DO NOT get any tape, compound, or other foreign material
into the pipe connections.
4. Install the kit components, as shown in the exploded view drawing
on page 1.
5. Place the system back in service by following the “Placing
the System in Service” section of the I-751.VDS Installation,
Maintenance, and Testing Manual.
6. Check the connections for any leaks. If any leaks are present,
depressurize and drain the system and repair any leaks.
* Teflon is a registered trademark of the DuPont Company
I-751.VDS/KIT_2
Series 751 FireLock European Alarm Check Valve Stations
AUXILIARY WATER MOTOR ALARM TEST VALVE KIT
I-751.VDS/KIT
KIT INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
PERFORMING THE WATER MOTOR ALARM TEST
1. Notify the authority having jurisdiction, remote station alarm
monitors, and anyone in the affected area that the water motor
alarm test will be performed.
2. Verify that the alarm line ball valve is open.
3. Open the auxiliary water motor alarm test ball valve.
3a. Confirm that mechanical and electrical alarms are activated and
that remote monitoring stations, if provided, receive an alarm
signal. NOTE: There may be a time delay if a Series 752 Retard
Chamber is installed.
4. Close the auxiliary water motor alarm test ball valve after proper
operation of all alarms is verified.
5. Confirm that all valves are in their normal operating positions (refer
to table below).
Valve Normal Operating Position
System Test Valve Closed
System Main Drain Valve Closed
Water Supply Main Control Valve Open
Alarm Line Ball Valve Open (Lockable)
Auxiliary Water Motor Alarm Test Ball Valve Closed (Lockable)
W AT ER MO T OR
ALAR M
SE R IE S 760
R
FM
APPROVE D
VdS
To
System
Water
Supply To
Drain
Alarm Line Ball
Valve (Normally
Open Lockable)
System Test Valve
(Normally Closed)
Water Supply Main
Control Valve
System Main Drain
Valve (Normally Closed)
Auxiliary Water Motor
Alarm Test Valve
(Normally Closed Lockable)
I-751.VDS/KIT_3
Series 751 FireLock European Alarm Check Valve Stations
AUXILIARY WATER MOTOR ALARM TEST VALVE KIT
I-751.VDS/KITKIT INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
Series 751 FireLock European Alarm Check Valve Stations
AUXILIARY WATER MOTOR ALARM TEST VALVE KIT
I-751.VDS/KITKIT INSTALLATION INSTRUCTIONS
I-751.VDS/KIT
For complete contact information, visit www.victaulic.com
I-751.VDS/KIT 5911 REV A UPDATED 10/2009 ZVDS751KIT
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.

Other Victaulic Control Unit manuals

Victaulic FireLock NXT 768 Series User manual

Victaulic

Victaulic FireLock NXT 768 Series User manual

Victaulic KOIL-KIT 799 Series User manual

Victaulic

Victaulic KOIL-KIT 799 Series User manual

Victaulic FireLock NXT 769 Series User manual

Victaulic

Victaulic FireLock NXT 769 Series User manual

Victaulic 871 Series User manual

Victaulic

Victaulic 871 Series User manual

Victaulic FireLock NXT 764 Series Guide

Victaulic

Victaulic FireLock NXT 764 Series Guide

Victaulic FireLock 247 Series User manual

Victaulic

Victaulic FireLock 247 Series User manual

Victaulic 769N FireLock NXT Series User manual

Victaulic

Victaulic 769N FireLock NXT Series User manual

Victaulic FireLock NXT 776 Series User manual

Victaulic

Victaulic FireLock NXT 776 Series User manual

Victaulic Vic-300 MasterSeal 761 Series User manual

Victaulic

Victaulic Vic-300 MasterSeal 761 Series User manual

Victaulic 809N User manual

Victaulic

Victaulic 809N User manual

Victaulic I-869E-3D User manual

Victaulic

Victaulic I-869E-3D User manual

Victaulic End Caps User manual

Victaulic

Victaulic End Caps User manual

Victaulic 769N FireLock NXT Series User manual

Victaulic

Victaulic 769N FireLock NXT Series User manual

Victaulic FireLock NXT 764 Series User manual

Victaulic

Victaulic FireLock NXT 764 Series User manual

Victaulic 751 FireLock Series User manual

Victaulic

Victaulic 751 FireLock Series User manual

Victaulic 317 Series User manual

Victaulic

Victaulic 317 Series User manual

Victaulic I-769N User manual

Victaulic

Victaulic I-769N User manual

Victaulic FireLock 758 Series User manual

Victaulic

Victaulic FireLock 758 Series User manual

Victaulic FireLock NXT 769 Series User manual

Victaulic

Victaulic FireLock NXT 769 Series User manual

Victaulic 867-4UF User manual

Victaulic

Victaulic 867-4UF User manual

Victaulic 795 Series User manual

Victaulic

Victaulic 795 Series User manual

Victaulic FireLock Vic-Strainer 732H Series Release note

Victaulic

Victaulic FireLock Vic-Strainer 732H Series Release note

Victaulic FireLock NXT 769N Series User manual

Victaulic

Victaulic FireLock NXT 769N Series User manual

Victaulic 867-7UF User manual

Victaulic

Victaulic 867-7UF User manual

Popular Control Unit manuals by other brands

AVCO 1500 Series Installation, operation & maintenance manual

AVCO

AVCO 1500 Series Installation, operation & maintenance manual

Alemite 8322 Service & operating manual

Alemite

Alemite 8322 Service & operating manual

Ohsung Electronics T007-MA-MD manual

Ohsung Electronics

Ohsung Electronics T007-MA-MD manual

Stollmann BlueMod+B20 user guide

Stollmann

Stollmann BlueMod+B20 user guide

Avidsen 127063 manual

Avidsen

Avidsen 127063 manual

ABB RTAC-01 user manual

ABB

ABB RTAC-01 user manual

Cypress Semiconductor CapSense CY3280-SLM quick start guide

Cypress Semiconductor

Cypress Semiconductor CapSense CY3280-SLM quick start guide

Wieland podis FCS 6 5 SI SA Installation instruction

Wieland

Wieland podis FCS 6 5 SI SA Installation instruction

Game ready 500055 user manual

Game ready

Game ready 500055 user manual

TLV CK3 Series instruction manual

TLV

TLV CK3 Series instruction manual

norbar T-Box 43543 Operator's manual

norbar

norbar T-Box 43543 Operator's manual

GAI-Tronics 10962-001 manual

GAI-Tronics

GAI-Tronics 10962-001 manual

Asco 8316 Series Installation & maintenance instructions

Asco

Asco 8316 Series Installation & maintenance instructions

DFI CH960-CM246 user manual

DFI

DFI CH960-CM246 user manual

LDT Digital-Professional Series operating instructions

LDT

LDT Digital-Professional Series operating instructions

Alderon Industries Mini Power Post PRPT-00003 user guide

Alderon Industries

Alderon Industries Mini Power Post PRPT-00003 user guide

Emerson Daniel 700 Series user manual

Emerson

Emerson Daniel 700 Series user manual

METROTEC GSM Series operating instructions

METROTEC

METROTEC GSM Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.