manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Victaulic
  6. •
  7. Control Unit
  8. •
  9. Victaulic FireLock 912 Service manual

Victaulic FireLock 912 Service manual

Other Victaulic Control Unit manuals

Victaulic 751 FireLock Series User manual

Victaulic

Victaulic 751 FireLock Series User manual

Victaulic FireLock NXT 768 Series User manual

Victaulic

Victaulic FireLock NXT 768 Series User manual

Victaulic FireLock NXT 764 Series Guide

Victaulic

Victaulic FireLock NXT 764 Series Guide

Victaulic 867-42T User manual

Victaulic

Victaulic 867-42T User manual

Victaulic FireLock 758 Series User manual

Victaulic

Victaulic FireLock 758 Series User manual

Victaulic FireLock Vic-Strainer 732H Series Release note

Victaulic

Victaulic FireLock Vic-Strainer 732H Series Release note

Victaulic FireLock 756 Series User manual

Victaulic

Victaulic FireLock 756 Series User manual

Victaulic 769N FireLock NXT Series User manual

Victaulic

Victaulic 769N FireLock NXT Series User manual

Victaulic I-869E-3D User manual

Victaulic

Victaulic I-869E-3D User manual

Victaulic I-769N User manual

Victaulic

Victaulic I-769N User manual

Victaulic 871 Series User manual

Victaulic

Victaulic 871 Series User manual

Victaulic 867-4UF User manual

Victaulic

Victaulic 867-4UF User manual

Victaulic KOIL-KIT 799 Series User manual

Victaulic

Victaulic KOIL-KIT 799 Series User manual

Victaulic FireLock NXT 764 Series User manual

Victaulic

Victaulic FireLock NXT 764 Series User manual

Victaulic 751 Series User manual

Victaulic

Victaulic 751 Series User manual

Victaulic 751 FireLock Series User manual

Victaulic

Victaulic 751 FireLock Series User manual

Victaulic 725S Series User manual

Victaulic

Victaulic 725S Series User manual

Victaulic FireLock I-756 Series User manual

Victaulic

Victaulic FireLock I-756 Series User manual

Victaulic 769N FireLock NXT Series User manual

Victaulic

Victaulic 769N FireLock NXT Series User manual

Victaulic 751 FireLock Series User manual

Victaulic

Victaulic 751 FireLock Series User manual

Victaulic FireLock NXT 776 Series User manual

Victaulic

Victaulic FireLock NXT 776 Series User manual

Victaulic FireLock 758-LPA Series User manual

Victaulic

Victaulic FireLock 758-LPA Series User manual

Victaulic 809N User manual

Victaulic

Victaulic 809N User manual

Victaulic FireLock NXT 764 Series User manual

Victaulic

Victaulic FireLock NXT 764 Series User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

I-912_1
FireLock®Low-Profile Sprinkler Outlet-T
STYLE 912
I-912INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
The Style 912 FireLock®Low-Profile Sprinkler Outlet-T is designed for direct connection of sprinkler heads and is FM Approved up to
300 psi/2068 kPa and VdS and LPCB Approved up to 16 Bar/232psi at ambient temperatures that are typical for fire protection systems.
PRODUCT DATA
W
Z
V
Y
Nominal Size
inches/Actual mm
Hole
Diameter
Approximate
Weight Each
Run x Branch FPT†
+0.06/+1,5
–0.00/–0,0 V W Y Z lbs/kg
1x½⁄ 1.00 0.90 3.72 1.50 0.67
33.7 15.0 24.0 25.4 22.9 94.6 38.1 0.30
1 ¼ x½⁄ 1.17 1.10 4.12 1.50 0.74
42.4 15.0 24.0 29.8 27.9 104.7 38.1 0.33
1 ½ x½⁄ 1.29 1.22 4.32 1.50 0.76
48.3 15.0 24.0 32.8 31.0 109.8 38.1 0.34
† Style 912 Low-Profile Sprinkler Outlet-T products are designed with female threads to ISO 7-Rp ½
(Rp ½ BSPP per BS21) and can accommodate only male sprinkler threads.
FOR SPRINKLER USE ONLY. DO NOT USE AS A BRANCH OUTLET.
WARNING
Read and understand all instructions before attempting to install any Victaulic piping products.•
Wear safety glasses, hardhat, and foot protection.•
Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products.•
Failure to follow these instructions could result in serious personal injury and/or property damage.
I-912_2
FireLock®Low-Profile Sprinkler Outlet-T
STYLE 912
I-912
INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
PIPE PREPARATION
NOTICE
Victaulic hole cutting tools are recommended for proper hole•
preparation.
1. Cut a ⁄-inch/24.0-mm hole on the centerline of the pipe.
¼ inch/6 mm
Exaggerated for clarity
2. Ensure that a ¼-inch/6-mm area around the hole is clean, smooth,
and free from indentations and/or projections that could affect
gasket sealing (refer to the sketch above). Remove any burrs and
sharp or rough edges from the hole that might affect assembly,
proper seating of the locating collar, flow from the outlet, or gasket
seating.
INSTALLATION
1. Make sure the gasket is seated fully in the gasket pocket. DO NOT
LUBRICATE THE GASKET.
2. Remove the flange nut and bolt from one side of the Style 912
assembly. Thread the remaining flange nut loosely onto the bolt
(flange nut should be flush with end of bolt) to allow for the
“swing-over” feature.
3. Install the outlet housing onto the pipe by centering the locating
collar in the hole. To check for proper engagement, slide the outlet
housing back and forth while pushing down. A properly positioned
outlet housing can be moved only a small amount in any direction.
3a. Rotate the lower housing around the pipe, while holding the outlet
housing in place to make sure the locating collar remains seated
properly in the hole.
4. Insert the other track bolt into the lower housing and outlet
housing. Thread the flange nut onto the bolt finger-tight. Make sure
the track heads of the bolts seat properly in the bolt holes.
I-912_3
FireLock®Low-Profile Sprinkler Outlet-T
STYLE 912
I-912INSTALLATION INSTRUCTIONS
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_A
5. Tighten the flange nuts evenly to an approximate torque value of
20 ft-lbs/27.1-N•m to ensure proper gasket compression. NOTE:
To avoid over-tightening the flange nuts, use a wrench with a
maximum length of 8 inches/200mm. DO NOT over-tighten the
flange nuts.
The outlet housing, near the gasket, should not make metal-to-metal
contact with the pipe. In addition, a small bolt pad gap is expected
between the outlet housing and the lower housing, as shown above.
WARNING
DO NOT over-tighten the flange nuts. Over-tightening the•
flange nuts can over-compress the gasket and distort the outlet
housing and lower housing. Over-tightening does not enhance
product performance.
Failure to follow this instruction could cause product failure,
resulting in serious personal injury and/or property damage.
I-912
FireLock®Low-Profile Sprinkler Outlet-T
STYLE 912
I-912INSTALLATION INSTRUCTIONS
For complete contact information, visit www.victaulic.com
I-912 5372 REV A Z000912000 UPDATED 11/2008
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
WCAS-7HHHTM