1 Turbine Compact Analog Stations
This document describes the dimensions, mounting procedure, and connections of the Turbine Compact
Analog Stations. Zenitel takes no responsibility for damages caused by improper or inadequate mounting.
The Turbine Compact Analog product range comprises the following stations & accessories:
Item Number Type Item Name
1008114010 TCAS-1 Turbine Compact Analog - thermoplastic front plate
1008114020 TCAS-2 Turbine Compact Analog - stainless steel front plate
1008114030 TCAS-3 Turbine Compact Analog - thermoplastic front plate
1008140010 TA-1 Turbine On-Wall Back Box
1008140030 TA-3 Turbine Flush Mount 2-Gang Back Box
1008140050 TA-5 Turbine Bracket for Flush Mount Back Box
TCAS-1 TCAS-2 TCAS-3
1.1 TCAS Compact Station Dimensions
120 mm
96 mm
156 mm
180 mm
33 mm 23.8 mm
Mounting Manual
TCAS Turbine Compact Analog
2 On-Wall Surface Mounting
2.1 On-Wall Surface Mount Back Box - TA-1
2.2 On-Wall Surface Mounting Procedure
1. Mount the back box onto the wall
2. Fit the gasket onto the back box with the ridged side facing down
–Plug the AlphaCom cable into the RJ-45 port on the station
3. Mount the Turbine station onto the back box with the M5 fasteners provided applying
1.5 Nm torque
76 mm
150 mm
D6.5 mm
25 mm
120 mm
Mounting holes are to be drilled
as shown.
Max. recommended screw
diameter: ISO M6 or ANSI 1/4".
Screw length must be greater
than 25 mm or 1".
A4 stainless steel socket head
screws/bolts are recommended.
Max. recommended screw
head diameter: 9.5 mm or 3/8".
3”
5.90”
4.72”
1”
0.25”
D
Mounting Hole
Mounting Hole Mounting Hole
Mounting Hole
Optional washers for extra protection
against corrosive effects between
surfaces are provided.
They should be placed at the bottom
of the 4 mounting holes.
Grommets and an M20 cable gland
are provided.
cable holes
M20 M16
Surface
Mount
Back Box
Gasket
1
2
Microphone
Washers
Turbine
Station
3LThe Gasket MUST be mounted to
seal the station!
LEnsure the station is mounted verti-
cally with the microphone aperture
facing down.
LEnsure there is enough clearance
under the station so that the micro-
phone aperture is NOT smothered.
LPlace the washers at the bottom of
the 4 mounting holes on the back
box.
LUse the grommets and M20 cable
gland provided for the cable holes
on the back box.
LIP-66 rating is only valid when
TA-1 Back Box is used
3 Flush Mounting
3.1 Flush Mount 2-Gang Back Box - TA-3
LIt is recommended to utilize back boxes with weep holes at the bottom
3.2 Flush Mount Bracket - TA-5
LThe TA-5 Bracket is mandatory for flush mounting.
83 mm
87 mm
46 mm
50 mm
4 mm
4 mm
74 mm
91 mm
Fits US 2-GANG electrical boxes.
Recommended screw diameter: up to M4 (5/32")
Use screw recommended by back box manufacurer.
CUTOUT
0.16”
1.81”
0.16”
3.58”
1.97”
3.42”
3.27”
2.91”
48 mm
25 mm
23 mm
46 mm
SIDE
SIDE
22 mm
96 mm / 3.78?
96 mm / 3.78?
0.87?
1.81? 0.98?
64 mm / 2.52?
64 mm / 2.52?
1.89?
0.90?
DOC NO.
Zenitel and its subsidiaries assume no responsibility for any errors that may appear in this publication, or for damages arising from the information therein. Vingtor-Stentofon products are developed and
marketed by Zenitel. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001. Zenitel reserves the right to modify designs and alter specifications without notice.
ZENITEL PROPRIETARY. This document and its supplementing elements, contain Zenitel or third party information which is proprietary and confidential. Any disclosure, copying, distribution or use is
prohibited, if not otherwise explicitly agreed in writing with Zenitel. Any authorized reproduction, in part or in whole, must include this legend: Zenitel – All rights reserved.
3.3 Flush Mounting Procedure
1. Mount the 2-gang back box into the wall
2. Mount the bracket onto the back box
3. Fit the gasket onto the bracket with the
ridged side facing down
–Plug the AlphaCom cable into the RJ-45 port
on the station
4. Mount the Turbine station onto the
bracket with the M5 fasteners provided
4 Connections
The Turbine analog station has an RJ-45 port and 6 external connectors.
Power Draws power from AlphaCom signal line.
RJ-45 port AlphaCom connection
A, B, C, D
wires
AlphaCom connection when RJ-45 port is not
used.
LUse cables crimped with ferrules for terminal block connectors
To set up the analog station as an intercom:
1. Connect the RJ-45 port on the station to the AlphaCom
server/exchange
2. Register the station in the AlphaCom server/exchange
A
D
C
B
RJ-45
port
External Speaker + (50 ohms)
AlphaCom connection
External Speaker - (50 ohms)
Internal Speaker
Volume Control
AlphaCom Connection
19.8.2019
A100K11258 customer[email protected]
LEnsure the station is mounted verti-
cally with the microphone aperture
facing down.
LEnsure there is enough clearance
under the station so that the micro-
phone aperture is NOT smothered.
LApply silicone sealant all around
the aluminum frame of the station,
making sure to leave the micro-
phone aperture open.
LThe Gasket MUST be mounted to seal the station!
2-Gang
Back Box
Gasket
1
3
Microphone
Bracket
2
Turbine
Station
4

This manual suits for next models

6

Other Vingtor Stentofon Intercom System manuals

Vingtor Stentofon ITSV-1 User manual

Vingtor Stentofon

Vingtor Stentofon ITSV-1 User manual

Vingtor Stentofon TCIS-1 User manual

Vingtor Stentofon

Vingtor Stentofon TCIS-1 User manual

Vingtor Stentofon Turbine Mini SIP Station Guide

Vingtor Stentofon

Vingtor Stentofon Turbine Mini SIP Station Guide

Vingtor Stentofon TCIV-2SIP Guide

Vingtor Stentofon

Vingtor Stentofon TCIV-2SIP Guide

Vingtor Stentofon Exigo Ex EAPFX-1 Guide

Vingtor Stentofon

Vingtor Stentofon Exigo Ex EAPFX-1 Guide

Vingtor Stentofon TCIV-2 Guide

Vingtor Stentofon

Vingtor Stentofon TCIV-2 Guide

Vingtor Stentofon Exigo Ex EAPFX-1 User manual

Vingtor Stentofon

Vingtor Stentofon Exigo Ex EAPFX-1 User manual

Vingtor Stentofon Turbine TMIS-1 Installation instructions manual

Vingtor Stentofon

Vingtor Stentofon Turbine TMIS-1 Installation instructions manual

Vingtor Stentofon TCIS-1SIP Guide

Vingtor Stentofon

Vingtor Stentofon TCIS-1SIP Guide

Vingtor Stentofon ECPIR-3P User manual

Vingtor Stentofon

Vingtor Stentofon ECPIR-3P User manual

Vingtor Stentofon TCIS Series User manual

Vingtor Stentofon

Vingtor Stentofon TCIS Series User manual

Vingtor Stentofon TCIS-1 User manual

Vingtor Stentofon

Vingtor Stentofon TCIS-1 User manual

Vingtor Stentofon TFIE-1 Guide

Vingtor Stentofon

Vingtor Stentofon TFIE-1 Guide

Vingtor Stentofon TCIS-1 Guide

Vingtor Stentofon

Vingtor Stentofon TCIS-1 Guide

Popular Intercom System manuals by other brands

GEV CVS 86104 manual

GEV

GEV CVS 86104 manual

CDVI CDV4796KP-DX manual

CDVI

CDVI CDV4796KP-DX manual

Security Brands ADVANTAGE DKLP 19-100 quick start guide

Security Brands

Security Brands ADVANTAGE DKLP 19-100 quick start guide

urmet domus 956 Installation and instruction manual

urmet domus

urmet domus 956 Installation and instruction manual

Panasonic VL-SWH705 Series Quick reference guide

Panasonic

Panasonic VL-SWH705 Series Quick reference guide

NatComm DP4 user manual

NatComm

NatComm DP4 user manual

BARIX annuncicom 100 Quick install guide

BARIX

BARIX annuncicom 100 Quick install guide

DSC PC5936 instructions

DSC

DSC PC5936 instructions

Auta 700105 user guide

Auta

Auta 700105 user guide

Farfisa CONNECTO TD1000CN manual

Farfisa

Farfisa CONNECTO TD1000CN manual

Avadesign DP-201 Installation and user guide

Avadesign

Avadesign DP-201 Installation and user guide

CyberData VoIP Intercom 010935F Operation guide

CyberData

CyberData VoIP Intercom 010935F Operation guide

urmet domus iPer com 1741 Quick user guide

urmet domus

urmet domus iPer com 1741 Quick user guide

Elvox 12B2 Installation and connection manual

Elvox

Elvox 12B2 Installation and connection manual

Arlo AVD3001 quick start guide

Arlo

Arlo AVD3001 quick start guide

Aiphone IX-SS-2RA installation manual

Aiphone

Aiphone IX-SS-2RA installation manual

Aiphone IBG-1GD instructions

Aiphone

Aiphone IBG-1GD instructions

CAME PLACO-VC installation manual

CAME

CAME PLACO-VC installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.