DE5468IP 1
POWERMAX PRO
Fully Supervised Wireless Alarm Control System Installer Guide
TABLE OF CONTENTS
1. INTRODUCTION ....................................................... 3
2. SPECIFICATIONS..................................................... 3
2.1 General Data ...............................................................3
2.2 RF Section ...................................................................3
2.3 Electrical Data..............................................................4
2.4 Communication............................................................4
2.5 Physical Properties ......................................................4
3. INSTALLATION ......................................................... 4
3.1 Unpacking the Equipment............................................4
3.2 Supplying Power to the Unit.........................................4
3.3 System Planning & Programming ................................4
3.4 Mounting ......................................................................4
3.5 Wiring...........................................................................4
3.6 Backup Battery Insertion..............................................6
3.7 X-10 Interface Module Connection..................................6
3.8 Optional GSM Module Mounting.....................................7
3.9 Additional Optional Module Mounting ..........................7
3.10 Power Cable Connection ...........................................7
3.11 Installing an Optional X-10 Siren ...............................9
3.12 Connecting to a Computer ...............................................9
4. PROGRAMMING..................................................... 10
4.1 INTRODUCTION .......................................................10
4.1.1 General Guidance...................................................10
4.1.2 Entering an Invalid Installer Code................................10
4.1.3 Installer’s Menu.......................................................10
4.1.4 Setting a New Installer Code ..................................10
4.1.5 Setting a New Installer Code in PowerMax Pro that
has 2 Installer Codes........................................................10
4.2 ENROLLING WIRELESS DEVICES AND KEYFOB
TRANSMITTERS.............................................................11
4.2.1 General Guidance...................................................11
4.2.2 Enrolling Type.........................................................11
4.2.3 Enroll/Delete Sensors .............................................11
4.2.4 Enroll/Delete Keyfob Transmitters.................................11
4.2.5 Enroll/Delete Wireless Commander................................11
4.2.6 Enroll/Delete 2-Way Keypad....................................11
4.2.7 Enroll/Delete Wireless Siren....................................11
4.2.8 Enroll/Delete Proximity Tags....................................11
4.3 DEFINING ZONE TYPES, NAMES & CHIME
ZONES......................................................................... 13
4.4 DEFINING CONTROL PANEL PARAMETERS.... 14
4.4.1 Preliminary Guidance..............................................14
4.4.2 Entry Delays 1&2 ......................................................14
4.4.3 Exit Delay................................................................14
4.4.4 Bell Time.................................................................14
4.4.5 Abort Time ..............................................................14
4.4.6 Alarm Cancel ..........................................................14
4.4.7 Quick Arm ...............................................................14
4.4.8 Bypass ....................................................................14
4.4.9 Exit Mode................................................................15
4.4.10 Piezo Beeps..........................................................15
4.4.11 Trouble Beeps ......................................................15
4.4.12 Panic Alarm ..........................................................15
4.4.13 Swinger Stop ........................................................15
4.4.14 Cross Zoning ........................................................15
4.4.15 Supervision ...........................................................15
4.4.16 NOT READY.........................................................15
4.4.17 AUX Button A........................................................15
4.4.18 AUX Button B 2-W-KF.............................................15
4.4.19 Jam Detect............................................................15
4.4.20 Latchkey ...............................................................15
4.4.21 “Not Active” ...........................................................16
4.4.22 Back Light .............................................................16
4.4.23 Duress ..................................................................16
4.4.24 Piezo Siren ...........................................................16
4.4.25 Reset Option.........................................................16
4.4.26 Tamper Option ..................................................... 16
4.4.27 Siren On Line ....................................................... 16
4.4.28 Memory Prompt.................................................... 16
4.4.29 Disarm Option ...................................................... 16
4.4.30 Bell/Rep. Option ................................................... 16
4.4.31 Low-Bat Ack ......................................................... 16
4.4.32 Screen Saver ....................................................... 16
4.4.33 Confirm Alarm ...................................................... 16
4.4.34 AC FAIL REP ....................................................... 16
4.4.36 User Permission................................................... 16
4.5 DEFINING COMMUNICATION PARAMETERS... 18
Preliminary Guidance ...................................................... 18
4.5.2 Autotest Cycle ........................................................ 18
4.5.3 Area Code .............................................................. 18
4.5.4 Out Access No ....................................................... 18
4.5.5 First Central Station Tel. ............................................... 18
4.5.6 First Account No..................................................... 18
4.5.7 2ND Central Station Tel.............................................. 18
4.5.8 Second Account No. .............................................. 18
4.5.9 Report Format ........................................................ 18
4.5.10 4/2 Pulse Rate...................................................... 18
4.5.11 Reporting to Central Stations .................................. 18
4.5.12 Report CNF Alarm.................................................. 18
4.5.13 Send 2WV Code .................................................... 18
4.5.14 Two-Way Voice Central Stations.............................. 19
4.5.15 Ring Back Time.................................................... 19
4.5.16 Dialing Attempts ................................................... 19
4.5.17 Set Private Tel. No. ................................................. 19
4.5.18 Two-Way Voice - Private Phones............................. 19
4.5.19 Private Tel. Dialing Attempts................................ 19
4.5.20 Reporting to Private Telephones .............................. 19
4.5.21 Tel. Acknowledge................................................... 19
4.5.22 Pager Tel. No. ...................................................... 19
4.5.23 Pager’s PIN No. ................................................... 19
4.5.24 Reporting to a Pager ............................................ 19
4.5.25 Recent Closure .................................................... 19
4.5.26 Remote Access .................................................... 19
4.5.27 Mast. DL Code ..................................................... 19
4.5.28 Inst. DL Code ....................................................... 19
4.5.30 Zone Restore ....................................................... 21
4.5.31 Upload Option ...................................................... 21
4.5.32 Dialing Method ..................................................... 21
4.5.33 Line Failure Report............................................... 21
4.5.34 UL/DL Tel. Number .............................................. 21
4.5.35 System Inactivity Report....................................... 21
4.5.38AmbientLevel ............................................................ 21
4.6 DEFINING GSM PARAMETERS .......................... 21
4.6.1 GSM Installation..................................................... 21
4.6.2 1st, 2nd, 3rd & 4th SMS Number............................... 21
4.6.3 Reporting to SMS Phone Number ............................. 21
4.6.4 GSM Line Failure Reporting................................... 21
4.6.5 GSM Purpose......................................................... 21
4.6.6 Select Antenna....................................................... 21
4.7 DEFINING POWERLINK....................................... 22
4.8 DEFINING OUTPUT PARAMETERS ................... 22
4.8.1 Preliminary Guidance ............................................. 22
4.8.2 Define PGM............................................................ 22
4.8.3 Defining INT/STRB................................................. 23
4.8.4 X-10 GENERAL DEF................................................ 23
4.8.5 X-10 UNIT DEFINE................................................. 23
4.9 DEFINE VOICE ..................................................... 25
4.9.1 Record Speech ...................................................... 25
4.9.2 Speech Box Mode.................................................. 25
4.10 DIAGNOSTIC TEST............................................ 25
4.11 USER FUNCTIONS ............................................ 26
4.12 RETRIEVING FACTORY DEFAULTS ................ 26