
4 Table of Contents WAGO-TO-PASS® 761
761-214 Telecontrol Module Compact, 8 AI, ESP, DSP
Manual
Version 2.0.0
3.6.5 Digital Inputs...................................................................................... 32
3.6.6 Counter Inputs.................................................................................... 32
3.6.7 Analog Inputs ..................................................................................... 32
3.6.8 Digital Outputs ................................................................................... 33
3.6.9 Analog Outputs................................................................................... 33
3.6.10 Data and Event Logger....................................................................... 33
3.7 Approvals................................................................................................ 34
3.8 Standards and Guidelines........................................................................ 34
4Mounting..................................................................................................... 35
4.1 Mounting the TO-PASS®telecontrol module to the DIN rail................. 35
4.2 Removing the TO-PASS®telecontrol module from the DIN rail............ 36
5Connect Devices ......................................................................................... 37
5.1 Connecting the Push-wire Connections to the Conductor ...................... 37
5.2 Connection Examples.............................................................................. 38
5.2.1 Digital Inputs...................................................................................... 38
5.2.2 Counter Inputs.................................................................................... 39
5.2.3 Analog Inputs ..................................................................................... 40
5.2.3.1 Current Measurement .................................................................... 40
5.2.3.2 Voltage Measurement.................................................................... 41
5.2.4 Digital Outputs ................................................................................... 42
5.2.5 Analog Outputs................................................................................... 43
5.2.5.1 Current Measurement .................................................................... 43
5.2.5.2 Voltage Measurement.................................................................... 44
6Commissioning........................................................................................... 45
6.1 Installing the Operating Software ........................................................... 45
6.2 Starting the TO-PASS®Telecontrol Module........................................... 46
7Parameterizing........................................................................................... 48
7.1 General Settings ...................................................................................... 48
7.2 Reading Parameters from the Module..................................................... 50
7.3 Identity .................................................................................................... 51
7.4 Addresses ................................................................................................ 53
7.5 Configuring Inputs and Outputs.............................................................. 56
7.5.1 Digital Inputs...................................................................................... 56
7.5.2 Multiplex Input................................................................................... 60
7.5.2.1 Multiplex Settings.......................................................................... 61
7.5.2.2 Multiplex Alarm Text.................................................................... 62
7.5.3 Analog Inputs ..................................................................................... 63
7.5.4 Digital Outputs ................................................................................... 65
7.5.5 Analog Outputs................................................................................... 66
7.6 Configuring Error Detectors ................................................................... 68
7.6.1 Alarm Messages for Digital Inputs..................................................... 68
7.6.2 Limit Messages for Counter Inputs.................................................... 68
7.6.3 Limit Messages for Analog Inputs..................................................... 68
7.6.4 Acknowledgement.............................................................................. 70
7.7 Transmission Repeat Times.................................................................... 71
7.8 Time Adjustment..................................................................................... 74
7.9 Data Logger............................................................................................. 75
7.10 Writing Parameters to the Module.......................................................... 76