3. INSTALLATION INFORMATION
Installation requirements:
A dedicated and properly earthed outlet. Unit should be protected by residual current
device (RCD) having a rated residual operating current not exceeding 30 mA.
The machine needs to be mounted on a firm level surface so there is no chance of it
toppling or falling over. A 100 mm air gap is required the whole way around the machine
to allow for sufficient ventilation.
The machine must not be installed in direct sunlight or next to a heat source. The supply
water must be potable and up to a maximum recommended temperature of 25°C (77°F).
Materials needed:
• PPE: rubber or nitrile safety gloves, safety footwear and protective eyewear
• Phillips screwdriver, temperature gauge, TDS meter and chlorine test strips
• Jug to collect water from the faucet and 10 litre container to drain the machine
• Aqua Dosa sanitise – or other 3% hydrogen peroxide
• ¼” plastic tubing and assorted ¼” quick connect fittings
• Sanitizing cartridge or Waterlogic filter housing without media.
• Install kit with non-return valve, pressure reducer and water block.
AUSTRALIAN INSTALLATION GUIDE
Installation Instructions
Installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
For installation, you will need: 1-20 metres of 6mm 5/16 inch water pipe,
John Guest fittings, moulded plug fitted, CO2 Gas (if required), CO2
Regulator and customer handbook. Allow 1 hour to complete installation.
•The Waterlogic units must be installed according to the local guidelines.
• A 350kpa pressure reducing valve and dual check valve must be connected at the
water supply.
•The Waterlogic units should not be connected to water supplies of unknown
bacterial quality or those not already fit for human consumption. The Waterlogic
units should only be connected to a potable drinking water supply.
• Waterlogic International strongly recommends the use of an anti-flood device.
•K001 Install kit , (1 x 63058/103988 – brass tee, 1 x 54011/104115 ball valve,
1 x52028/104177 dual check valve or 52010 / 100665 alternate dual check valve).
• After hours sales/service – 1300 88 14 14.
3.1 START-UP INFORMATION
• It is advisable to have the power and flexible water supply within a two meters range of
the machine. If water supply is further than two meters, rigid fixed permanent pipework
is required. All water connections shall be that of a fixed permanent solution and not by
temporary means of fixture:
0 - 2 meters: ≥ 1/4” JG pipe
2 - 10 meters: ≥ 15 mm pipe
Onlycompetenttrained techniciansshouldwork onWaterlogicproducts.Waterlogicunitsmay
weigh over25kg.We recommend cautionwhenlifting.Packingmaterialscould presenta trip
hazard.Keep them off the floor.